Back to Authors

Weber, Matthew P

0000-0002-5302-2065

Mayo Clinic

Sidney Kimmel Medical College, Philadelphia, PA, USA.

Citations 2

Quality of life metrics in LVAD patients after hemocompatibility‐related adverse events
Weber, Matthew P. , Stulak, John M., Maltais, Simon, Tchantchaleishvili, Vakhtang , Weber, Matthew P , Pagani, Francis D. , Cowger, Jennifer , Tchantchaleishvili, Vakhtang

Artificial Organs | March 22, 2022 | Volume: 46 | Issue: 8 | Pages: 1616-1625

10.1111/aor.14235 Get It

Abstract Background Hemocompatibility‐related adverse events (HRAE) negatively influence survival. However, no study has examined the impact of these events on health‐related quality of life (HRQOL) and functional outcomes following continuous‐flow left ventricular assist device implantation (CF‐LVAD). We assessed the impact of HRAE events on HRQOL and hypothesized that HRAE's adversely impact HRQOL and functional outcomes. Methods INTERMACS database identified patients undergoing primary CF‐LVAD implantation from 2008 to 2017. HRAEs included stroke, non‐surgical bleeding, hemolysis, and pump thrombosis and were identified as defined in the literature. HRAEs were further stratified as Tier 1–2 and disabling stroke events. Time‐series analysis was executed for HRAE patients with values pre‐HRAE, post‐HRAE, and closest to 12 months follow up. Local polynomial regression curves modeling individual patients were superimposed into “spaghetti” plots. Results All HRQOL and functional metrics improved in patients over time, despite HRAE complications. However, these patient metrics were significantly reduced compared to the non‐HRAE cohort. Advanced data visualization techniques noted a decline after experiencing an HRAE with a subsequent recovery to baseline levels or higher. Six‐minute walk test (6MWT) was noted to be most affected in the post‐HRAE period but recovered similar to other metrics. Conclusions The burden of HRAE following CF‐LVAD implantation did not negatively impact the quality of life. However, the 6MWT did not increase in the post‐HRAE period in all HRAE patients. Improvement of heart failure symptoms after CF‐LVAD coupled with optimal management following the HRAE act to preserve the enhanced quality of life.
Intraoperative prothrombin complex concentrate administration and outcomes in patients undergoing left ventricular assist device implantation
Boswell, Michael R. , Stulak, John M., Weber, Matthew P. , Tchantchaleishvili, Vakhtang , Weber, Matthew P , Smith, Mark M , Boswell, Michael R., Tchantchaleishvili, Vakhtang , Warner, Matthew A. , Smith, Bradford B. , Smith, Mark M.

Artificial Organs | January 20, 2021 | Volume: 45 | Issue: 8 | Pages: No page available

10.1111/aor.13918 Get It

Abstract Prothrombin complex concentrate (PCC) administration has increased among cardiac surgery patients in recent years; however, use in LVAD implantation/exchange is not widespread due to the fear of thrombotic complications. The purpose of this study was to compare the clinical outcomes of patients undergoing LVAD implantation/exchange with intraoperative PCC administration versus traditional transfusion practices alone. Adult LVAD implants/exchanges at our institution between 2015 and 2018 were included. Patients were categorized as receiving intraoperative PCC or no‐PCC (traditional). The primary outcome was the need for allogenic transfusion and transfusion volume at 48 hours after initial intensive care unit (ICU) admission. Secondary outcomes included metrics of morbidity and mortality. A total of 160 patients (39 PCC, 121 traditional) were analyzed. In unadjusted analysis, patients in the PCC group received lower intraoperative transfusion volumes compared to the traditional group although not statistically significant (1464 mL [IQR 796, 4876] vs. 2568 mL [IQR 1292, 3606]; P value .37). In the fully adjusted analysis, patients in the PCC group had increased odds of transfusion within 48 hours of ICU admission (OR 4.06, 95% CI: 1.35‐12.20; P < .01); however, there was no significant difference in transfusion volumes ( P = .09). Patients receiving PCCs had higher incidence of deep vein thrombosis (10.3% vs. 0%; P < .01) and 30‐day mortality (17.9% vs. 4.1%; P < .01). LVAD pump thrombosis occurred in 2.6% versus 0.8% in the PCC and traditional groups, respectively; P = .98. Patients undergoing LVAD implantation and exchange represent a complex surgical cohort. The results of this study suggest that the intraoperative PCC use during LVAD implant/exchange was associated with reduced intraoperative transfusions. Intraoperative PCC use was, however, associated with higher odds of postoperative transfusion, although transfusion volumes were not significantly different. While the deep vein thrombosis and 30‐day mortality rates were higher in the PCC group, these results are likely related to the degree of surgical and patient complexity rather than PCC use itself. Further studies are needed to assess PCC use in this surgical cohort.