Back to Authors

Olteanu, Horatiu

0000-0001-5783-4485

Mayo Clinic

Division of Hematopathology, Mayo Clinic, Rochester, Minnesota, USA.

Citations 23

Superior detection rate of plasma cell FISH using FACS-FISH
Gagnon, Marie-France, Midthun, Sally M, Fangel, James A, Schuh, Cynthia M, Luoma, Ivy, Pearce, Kathryn E., Meyer, Reid G., Arribas, Mariano , Zepeda‐Mendoza, Cinthya , Xu, Xinjie , Greipp, Patricia T. , Timm, Michael, Otteson, Gregory E., Olteanu, Horatiu , Kumar, Shaji , Luoma, Ivy M, Arribas, Mariano J, Zepeda-Mendoza, Cinthya, Timm, Michael M, Shi, Min , Jevremovic, Dragan , Olteanu, Horatiu , Greipp, Patricia T , Ailawadhi, Sikander , Braggio, Esteban , Fonseca, Rafaël , Rajkumar, S. Vincent , Jevremović, Dragan , Peterson, Jess F. , Ketterling, Rhett P. , Baughn, Linda B.

American Journal of Clinical Pathology | September 2, 2023 | Volume: 161 | Issue: 1 | Pages: 60-70

10.1093/ajcp/aqad108 Get It

Abstract Objectives Fluorescence in situ hybridization (FISH) for plasma cell neoplasms (PCNs) requires plasma cell (PC) identification or purification strategies to optimize results. We compared the efficacy of cytoplasmic immunoglobulin FISH (cIg-FISH) and fluorescence-activated cell sorting FISH (FACS-FISH) in a clinical laboratory setting. Methods The FISH analysis results of 14,855 samples from individuals with a suspected PCN subjected to cytogenetic evaluation between 2019 and 2022 with cIg-FISH (n = 6917) or FACS-FISH (n = 7938) testing were analyzed. Results Fluorescence-activated cell sorting–FISH increased the detection rate of abnormalities in comparison with cIg-FISH, with abnormal results documented in 54% vs 50% of cases, respectively (P < .001). It improved the detection of IGH::CCND1 (P < .001), IGH::MAF (P < .001), IGH::MAFB (P < .001), other IGH rearrangements (P < .001), and gains/amplifications of 1q (P < .001), whereas the detection rates of IGH::FGFR3 fusions (P = .3), loss of 17p (P = .3), and other abnormalities, including hyperdiploidy (P = .5), were similar. Insufficient PC yield for FISH analysis was decreased between cIg-FISH and FACS-FISH (22% and 3% respectively, P < .001). Flow cytometry allowed establishment of ploidy status in 91% of cases. In addition, FACS-FISH decreased analysis times, workload efforts, and operating costs. Conclusions Fluorescence-activated cell sorting–FISH is an efficient PC purification strategy that affords significant improvement in diagnostic yield and decreases workflow requirements in comparison with cIg-FISH.
Targeted testing of bone marrow specimens with cytoplasmic vacuolization to identify previously undiagnosed cases of VEXAS syndrome
Hines, Alexander , Bock, Allison R, Warrington, Kenneth J. , Olteanu, Horatiu , Patnaik, Mrinal M. , Reichard, Kaaren K. , Hines, Alexander S , Warrington, Kenneth J , Olteanu, Horatiu , Koster, Matthew J. , Bock, Allison R, Go, Ronald S. , Lasho, Terra L.

Rheumatology | May 25, 2023 | Volume: 62 | Issue: 12 | Pages: 3947-3951

10.1093/rheumatology/kead245 Get It

Abstract Objective To retrospectively identify patients with VEXAS syndrome (vacuoles, E1 enzyme, X-linked, autoinflammatory, somatic syndrome) among male patients with bone marrow vacuolization using a clinically applicable, targeted-screening approach. Methods Bone marrow reports from 1 May 2014 through 18 February 2022 were reviewed for documentation of cytoplasmic vacuolization. Patients with acute leukaemia, lymphoma, metastatic solid tumour, amyloidosis or POEMS (polyneuropathy, organomegaly, endocrinopathy, monoclonal protein, skin changes) syndrome were excluded, as were those without clinical records available for direct chart review. Cases were rated for suspicion of VEXAS syndrome using a 5-point scale based on the presence of laboratory findings, clinical features and treatment response. Patients with available DNA material and moderate (three patients) or high (four to five patients) suspicion were tested for somatic UBA1 variants associated with VEXAS syndrome. Results A total of 315 reports from 292 unique patients included documentation of vacuolization. Following exclusion criteria, 64 patients underwent direct medical chart review to assess likelihood of VEXAS syndrome, for which 21 patients met moderate to high suspicion. Available DNA was present in eight patients, seven (87.5%) of whom had a pathogenic somatic UBA1 variant consistent with VEXAS syndrome. The distribution of cytoplasmic vacuolization in the bone marrow biopsy reports among patients with VEXAS syndrome were erythroid and myeloid precursors (6/7), erythroid precursors only (1/7) and myeloid precursors only (0/7). Conclusion In this study, the utilization of a clinically applicable targeted-screening approach to test bone marrow specimens (with vacuolization) for the presence of previously undiagnosed VEXAS syndrome resulted in a positive detection rate of 87.5%.
Spectrum of clonal hematopoiesis in VEXAS syndrome
Gutierrez‐Rodrigues, Fernanda , Kusne, Yael , Ma, Xiaoyang , Alessi, Hugh, Finke, Christy M. , Mangaonkar, Abhishek A. , Begna, Kebede H. , Viswanatha, David S., Ferrada, Marcela A. , Wilson, Lorena, Kourelis, Taxiarchis , Reichard, Kaaren K. , Olteanu, Horatiu , Darden, Ivana, Hironaka, Dalton, Alemu, Lemlem, Kajigaya, Sachiko , Calado, Rodrigo T. , Rosenzweig, Sofia , Kastner, Daniel L. , Grayson, Peter C. , Young, Neal S. , Beck, David B. , Patnaik, Mrinal M. , Begna, Kebede , Xie, Zhuoer , Viswanatha, David, Kourelis, Taxiarchis , Olteanu, Horatiu , Kajigaya, Sachiko , Rosenzweig, Sofia , Calado, Rodrigo T , Groarke, Emma M , Patnaik, Mrinal , Ferrada, Marcela A , Fernandez, Jenna , Lasho, Terra L. , Shalhoub, Ruba N. , Koster, Matthew J. , Warrington, Kenneth J. , Xie, Zhuoer , Ombrello, Amanda K. , Go, Ronald S. , Calvo, Katherine R. , Wu, Colin O. , Patel, Bhavisha A.

Blood Journal | April 21, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1182/blood.2022018774 Get It

VEXAS is caused by somatic mutations in UBA1 (UBA1mut) and characterized by heterogenous systemic auto-inflammation and progressive hematologic manifestations, meeting criteria for myelodysplastic syndrome (MDS) and plasma cell dyscrasias. The landscape of myeloid-related gene mutations leading to typical clonal hematopoiesis (CH) in these patients is unknown. Retrospectively, we screened 80 VEXAS patients for CH in their peripheral blood (PB) and correlated findings with clinical outcomes in 77. UBA1mutwere most common at hotspot p.M41 (median variant allele frequency/VAF = 75%). Typical CH mutations co-occurred with UBA1mut in 60% of patients, mostly in DNMT3A and TET2, and were not associated with inflammatory or hematologic manifestations. In prospective single-cell proteogenomic sequencing (scDNA), UBA1mutwas the dominant clone, present mostly in branched clonal trajectories. Based on integrated bulk and scDNA analyses, clonality in VEXAS followed two major patterns: with either typical CH preceding UBA1mutselection in a clone (Pattern 1), or occurring as an UBA1mutsubclone or in independent clones (Pattern 2). VAF in PB differed markedly between DNMT3A and TET2 clones (median VAF of 25% vs 1%). DNMT3A and TET2 clones associated with hierarchies representing patterns 1 and 2, respectively. Overall survival for all patients was 60% at 10 years. Transfusion-dependent anemia, moderate thrombocytopenia, and typical CH mutations, each correlated with poor outcome. In VEXAS, UBA1mut cells are the primary cause of systemic inflammation and marrow failure, being a new molecularly defined somatic entity associated with MDS. VEXAS-associated MDS is distinct from classical MDS in its presentation and clinical course.
Improved semiautomated detection of TRBC-restricted Sézary cells unveils a spectrum of clonal cluster immunophenotypes
Otteson, Gregory E., Seheult, Jansen N. , Olteanu, Horatiu , Horna, Pedro , Otteson, Gregory, Olteanu, Horatiu , Seheult, Jansen N , Shi, Min , Jevremović, Dragan

Blood | August 29, 2022 | Volume: 140 | Issue: 26 | Pages: 2852-2856

10.1182/blood.2022017548 Get It

Abnormal CD13/HLA-DR Expression Pattern on Myeloblasts Predicts Development of Myeloid Neoplasia in Patients With Clonal Cytopenia of Undetermined Significance
Jevremović, Dragan , Nanaa, Ahmad , Geyer, Susan M. , Timm, Michael, Azouz, Haya , Hengel, Cynthia, Reberg, Alexander, He, Rong , Viswanatha, David S., Salama, Mohamad E., Olteanu, Horatiu , Otteson, Gregory E., Greipp, Patricia T. , Xie, Zhuoer , Litzow, Mark R. , Patnaik, Mrinal M. , Al‐Kali, Aref , Nguyen, Phuong L., Viswanatha, David, Shi, Min , Olteanu, Horatiu , Horna, Pedro , Otteson, Gregory, Jevremovic, Dragan , Xie, Zhuoer , Greipp, Patricia T , Alkhateeb, Hassan B. , Hogan, William J. , Shah, Meera

American Journal of Clinical Pathology | August 8, 2022 | Volume: 158 | Issue: 4 | Pages: 530-536

10.1093/ajcp/aqac083 Get It

Abstract Objectives Patients with clonal cytopenia of undetermined significance (CCUS) are at increased risk of developing myeloid neoplasia (MN). We evaluated whether a simple flow cytometry immunophenotyping (FCIP) assay could differentiate the risk of development of MN in patients with CCUS. Methods Bone marrow aspirates were assessed by FCIP panel in a cohort of 80 patients identified as having CCUS based on next-generation sequencing or cytogenetics from March 2015 to May 2020, with available samples. Flow cytometric assay included CD13/HLA-DR expression pattern on CD34-positive myeloblasts; CD13/CD16 pattern on maturing granulocytic precursors; and aberrant expression of CD2, CD7, or CD56 on CD34-positive myeloblasts. Relevant demographic, comorbidity, and clinical and laboratory data, including the type and extent of genetic abnormalities, were extracted from the electronic health record. Results In total, 17 (21%) patients with CCUS developed MN over the follow-up period (median survival follow-up, 28 months [95% confidence interval, 19-31]). Flow cytometry immunophenotyping abnormalities, including the aberrant pattern of CD13/HLA-DR expression, as detected at the time of the diagnosis of CCUS, were significantly associated with risk of developing MN (hazard ratio, 2.97; P = .006). Additional FCIP parameters associated with the development of MN included abnormal expression of CD7 on myeloblasts and the presence vs absence of any FCIP abnormality. Conclusions A simple FCIP approach that includes assessment of CD13/HLA-DR pattern on CD34-positive myeloblasts can be useful in identifying patients with CCUS at higher risk of developing MN.
Spurious CD34 expression in B‐cell lymphoma due to nonspecific binding to PerCP‐Cy5.5 fluorochrome conjugates: A rare phenomenon and a diagnostic pitfall
Timm, Michael, Howard, Matthew T., Yuan, Ji, Greipp, Patricia T. , Peterson, Jess F. , Roh, Dana J., Olteanu, Horatiu , Ji, Yuan , Timm, Michael M, Horna, Pedro , Olteanu, Horatiu , Peterson, Jess F , Greipp, Patricia T , Yuan, Ji , Shi, Min , Jevremović, Dragan

Cytometry Part B: Clinical Cytometry | June 2, 2022 | Volume: 102 | Issue: 4 | Pages: 326-328

10.1002/cyto.b.22079 Get It

Artificial Intelligence Enhances Diagnostic Flow Cytometry Workflow in the Detection of Minimal Residual Disease of Chronic Lymphocytic Leukemia
Salama, Mohamed E. , Otteson, Gregory E., Camp, Jon J. , Seheult, Jansen N. , Holmes, David R. , Olteanu, Horatiu , Shi, Min , Olteanu, Horatiu , Shi, Min , Seheult, Jansen N , Jevremović, Dragan , Holmes, David R.

Cancers | May 21, 2022 | Volume: 14 | Issue: 10 | Pages: 2537

10.3390/cancers14102537 Get It

Flow cytometric (FC) immunophenotyping is critical but time-consuming in diagnosing minimal residual disease (MRD). We evaluated whether human-in-the-loop artificial intelligence (AI) could improve the efficiency of clinical laboratories in detecting MRD in chronic lymphocytic leukemia (CLL). We developed deep neural networks (DNN) that were trained on a 10-color CLL MRD panel from treated CLL patients, including DNN trained on the full cohort of 202 patients (F-DNN) and DNN trained on 138 patients with low-event cases (MRD < 1000 events) (L-DNN). A hybrid DNN approach was utilized, with F-DNN and L-DNN applied sequentially to cases. “Ground truth” classification of CLL MRD was confirmed by expert analysis. The hybrid DNN approach demonstrated an overall accuracy of 97.1% (95% CI: 84.7–99.9%) in an independent cohort of 34 unknown samples. When CLL cells were reported as a percentage of total white blood cells, there was excellent correlation between the DNN and expert analysis [r > 0.999; Passing–Bablok slope = 0.997 (95% CI: 0.988–0.999) and intercept = 0.001 (95% CI: 0.000–0.001)]. Gating time was dramatically reduced to 12 s/case by DNN from 15 min/case by the manual process. The proposed DNN demonstrated high accuracy in CLL MRD detection and significantly improved workflow efficiency. Additional clinical validation is needed before it can be fully integrated into the existing clinical laboratory practice.
Evaluation of multiple myeloma measurable residual disease by high sensitivity flow cytometry: An international harmonized approach for data analysis
Soh, Kah Teong , Came, Neil , Otteson, Gregory E., Olteanu, Horatiu , Natoni, Alessandro , Lagoo, Anand S., Theakston, Edward, Óskarsson, Jón Þórir , Gorniak, Malgorzata , Grigoriadis, George, Arroz, Maria , Fletcher, Matthew , Ludwig, Peter S., Tembhare, Prashant , Matuzevičienė, Rėda , Radzevičius, Mantas , Kay, Sigi, Chen, Weina , Cabrita, Carina, Wallace, Paul K. , Olteanu, Horatiu , Tembhare, Prashant , Chen, Weina , Jevremović, Dragan , Shi, Min , Fletcher, Matthew, Lin, Pei , Ludwig, Peter

Cytometry Part B: Clinical Cytometry | January 10, 2022 | Volume: 102 | Issue: 2 | Pages: 88-106

10.1002/cyto.b.22053 Get It

AbstractBackgroundMultiple myeloma (MM) measurable residual disease (MRD) evaluated by flow cytometry is a surrogate for progression‐free and overall survival in clinical trials. However, analysis and reporting between centers lack uniformity. We designed and evaluated a consensus protocol for MM MRD analysis to reduce inter‐laboratory variation in MM MRD reporting.MethodsSeventeen participants from 13 countries performed blinded analysis of the same eight de‐identified flow cytometry files from patients with/without MRD using their own method (Stage 1). A consensus gating protocol was then designed following survey and discussions, and the data re‐analyzed for MRD and other bone marrow cells (Stage 2). Inter‐laboratory variation using the consensus strategy was reassessed for another 10 cases and compared with earlier results (Stage 3).ResultsIn Stage 1, participants agreed on MRD+/MRD− status 89% and 68% of the time respectively. Inter‐observer variation was high for total numbers of analyzed cells, total and normal plasma cells (PCs), limit of detection, lower limit of quantification, and enumeration of cell populations that determine sample adequacy. The identification of abnormal PCs remained relatively consistent. By consensus method, average agreement on MRD− status improved to 74%. Better consistency enumerating all parameters among operators resulted in near‐unanimous agreement on sample adequacy.ConclusionUniform flow cytometry data analysis substantially reduced inter‐laboratory variation in reporting multiple components of the MM MRD assay. Adoption of a harmonized approach would meet an important need for conformity in reporting MM MRD for clinical trials, and wider acceptance of MM MRD as a surrogate clinical endpoint.
Flow Cytometric Evaluation of Surface and Cytoplasmic TRBC1 Expression in the Differential Diagnosis of Immature T-Cell Proliferations
Otteson, Gregory E., Shi, Min , Jevremović, Dragan , Ji, Yuan , Olteanu, Horatiu , Horna, Pedro , Shi, Min , Jevremovic, Dragan , Olteanu, Horatiu , Yuan, Ji

American Journal of Clinical Pathology | May 6, 2021 | Volume: 157 | Issue: 1 | Pages: 64-72

10.1093/ajcp/aqab098 Get It

Abstract Objectives Flow cytometric detection of T-cell clonality is challenging, particularly in differential diagnosis of immature T-cell proliferations. Studies have shown utility of TRBC1, in conjunction with other T-cell markers, as reliable means to identify T-cell clonality by flow cytometry. One limitation of surface TRBC1 (sTRBC1) evaluation is it cannot be detected in surface CD3 (sCD3)-negative T cells, such as normal or abnormal immature T-cell precursors. Here, we assess surface and cytoplasmic TRBC1 expression patterns in the differential diagnosis of T-lymphoblastic leukemia/lymphoma (T-ALL) vs normal thymocyte expansions. Methods Forty-three samples containing T-ALL, thymoma, normal thymus, and/or indolent T-lymphoblastic proliferation (i-TLBP), were evaluated. Results All 24 cases with normal thymocytes or i-TLBPs revealed a characteristic and reproducible sCD3/sTRBC1 expression pattern indicative of polytypic T-cell maturation. In contrast, all 19 T-ALLs lacked this polytypic maturation pattern and were either completely negative for sCD3/sTRBC1 or showed a minor sCD3-positive subset with a monotypic TRBC1 expression pattern. Cytoplasmic TRBC1 evaluation in 9 T-ALLs demonstrated a monotypic intracellular TRBC1-positive (n = 4) or TRBC1-negative (n = 5) expression, indicative of clonality. Conclusions Our findings demonstrate flow cytometric evaluation of surface and cytoplasmic TRBC1 expression can aid detection of T-cell clonality and differential diagnosis of immature T-cell proliferations.
Emerging Role of T-cell Receptor Constant β Chain-1 (TRBC1) Expression in the Flow Cytometric Diagnosis of T-cell Malignancies
Horna, Pedro , Olteanu, Horatiu , Johansson, Ulrika , Olteanu, Horatiu , Horna, Pedro , Shi, Min

International Journal of Molecular Sciences | February 12, 2021 | Volume: 22 | Issue: 4 | Pages: 1817

10.3390/ijms22041817 Get It

T-cell clonality testing is integral to the diagnostic work-up of T-cell malignancies; however, current methods lack specificity and sensitivity, which can make the diagnostic process difficult. The recent discovery of a monoclonal antibody (mAb) specific for human TRBC1 will greatly improve the outlook for T-cell malignancy diagnostics. The anti-TRBC1 mAb can be used in flow cytometry immunophenotyping assays to provide a low-cost, robust, and highly specific test that detects clonality of immunophenotypically distinct T-cell populations. Recent studies demonstrate the clinical utility of this approach in several contexts; use of this antibody in appropriately designed flow cytometry panels improves detection of circulating disease in patients with cutaneous T-cell lymphoma, eliminates the need for molecular clonality testing in the context of large granular lymphocyte leukemia, and provides more conclusive results in the context of many other T-cell disorders. It is worth noting that the increased ability to detect discrete clonal T-cell populations means that identification of T-cell clones of uncertain clinical significance (T-CUS) will become more common. This review discusses this new antibody and describes how it defines clonal T-cells. We present and discuss assay design and summarize findings to date about the use of flow cytometry TRBC1 analysis in the field of diagnostics, including lymph node and fluid sample investigations. We also make suggestions about how to apply the assay results in clinical work-ups, including how to interpret and report findings of T-CUS. Finally, we highlight areas that we think will benefit from further research.