Back to Authors

Johnson, Pamela M.

https://orcid.org/0000-0001-7217-4630

Mayo Clinic

Mayo Clinic in Florida

Citations 4

Optimizing Thawed Plasma Inventories
Kuker, Kasey N., Badjie, Karafa S., Johnson, Pamela M. , Bundy, Kevin L., Buskirk, Camille M. van , Stubbs, R. James , Bundy, Kevin L.

American Journal of Clinical Pathology | February 16, 2016 | Volume: 138 | Issue: suppl_1 | Pages: A255-A255

10.1093/ajcp/138.suppl1.237 Get It

Multicenter Comparison of Emergency Release Group A versus AB Plasma in Blunt-Injured Trauma Patients
Zielinski, Martin D. , Schrager, Jason, Johnson, Pamela M. , Stubbs, James R. , Polites, Stephanie F. , Zietlow, Scott P., Jenkins, Donald H. , Robinson, Bryce R. H.

Clinical and Translational Science | September 9, 2014 | Volume: 8 | Issue: 1 | Pages: 43-47

10.1111/cts.12206 Get It

Implementation of an intraoperative blood transport and storage initiative and its effect on reducing red blood cell and plasma waste
Brown, Michael J., Button, Lisa M., Badjie, Karafa S., Guyer, Jean M., Dhanorker, Sarah R., Brach, Erin J., Johnson, Pamela M. , Stubbs, James R. , Guyer, Jean M

Transfusion | July 1, 2013 | Volume: 54 | Issue: 3 | Pages: 701-707

10.1111/trf.12315 Get It

Background The national waste rate for hospital‐issued blood products ranges from 0% to 6%, with operating room–responsible waste representing up to 70% of total hospital waste. A common reason for blood product waste is inadequate intraoperative storage. Study Design and Methods Our transfusion service database was used to quantify and categorize red blood cell ( RBC ) and fresh‐frozen plasma ( FFP ) units issued for intraoperative transfusion that were wasted over a 27‐month period. Two cohorts were created: 1) before implementation of a blood transport and storage initiative ( BTSI )— RBC and plasma waste J anuary 1, 2011‐ M ay 31, 2012; 2) after implementation of BTSI — RBC and plasma waste J une 1, 2012, to M arch 31, 2013. The BTSI replaced existing storage coolers (8‐hr coolant life span with temperature range of 1‐10°C) with a cooler that had a coolant life span of 18 hours and a temperature range of 1 to 6°C and included an improved educational cooler placard and an alert mechanism in the electronic health record. Monthly median RBC and plasma waste and its associated cost were the primary outcomes. Results An intraoperative BTSI significantly reduced median monthly RBC (1.3% vs. 0.07%) and FFP (0.4% vs. 0%) waste and its associated institutional cost. The majority of blood product waste was due to an unacceptable temperature of unused returned blood products. Conclusion An intraoperative BTSI significantly reduced median monthly RBC and FFP waste. The cost to implement this initiative was small, resulting in a significant estimated return on investment that may be reproducible in institutions other than ours.
Risks and adverse outcomes associated with emergency‐release red blood cell transfusion
Mulay, Sudhanshu , Jaben, Elizabeth A., Johnson, Pamela M. , Badjie, Karafa S., Stubbs, James R.

Transfusion | October 16, 2012 | Volume: 53 | Issue: 7 | Pages: 1416-1420

10.1111/j.1537-2995.2012.03922.x Get It

BackgroundGroup O red blood cell (RBC) units are used for emergency transfusions and are often uncrossmatched when transfused. We sought to determine the risk of alloimmunization and identify acute adverse outcomes of this practice.Study Design and MethodsThe transfusion medicine database was searched for emergency‐release transfusion (ERT) episodes from January 2006 through December 2010. The data collected included age and sex of the recipient, blood bank history, survival after the ERT episode, antibody screen results, antibody identifications, and compatibility of released units.ResultsA total of 1444 ERT episodes took place involving 1407 patients. A total of 4144 RBC units were released. Of the 129 positive antibody screens, 34 had no antibody on further work‐up, 14 had autoantibodies, 48 had a single antibody specificity, and 25 had multiple antibody specificities. Seven patients developed an antibody that could be attributed to the ERT episode, and 15 patients developed an antibody after ERT and additional RBC transfusions. There were 32 reported suspected transfusion reactions. No acute hemolytic transfusion reactions were reported. Seven patients were given a total of 10 incompatible RBC units. Of these patients, one developed a delayed serologic transfusion reaction. The rate of alloimmunization attributable to ERT was 3%. Overall, the rate of incompatible transfusion was less than 0.3% and the rate of a delayed hemolytic transfusion reaction was approximately 0.02%.ConclusionThere is minimal risk associated with the release of emergency uncrossmatched blood in the setting of an acutely bleeding patient. [Correction statement added after online publication 15‐Oct‐2012: the number of patients with autoantibodies, single antibody specificity and multiple antibody specificity has been update.]