Back to Authors

Guru, Pramod K

0000-0001-7695-4407

Mayo Clinic

Department of Critical Care, Mayo Clinic, Jacksonville, Florida, USA.

Citations 6

Rethinking Measures and Mortality Attribution in Health Care: The ENT Example
Patel, Samip , Olivero, Lorenzo , FRÍAS, JORGE SINCLAIR DE , Anderson, Stephanie S., Pollock, Ben D., Lee, Marian D., Chirilă, Răzvan M. , Guru, Pramod , Pollock, Benjamin D. , Sinclair, Jorge Enrique , Guru, Pramod K , Taylor, Richard, Moreno Franco, Pablo , Patel, Samip N , Pollock, Benjamin D , Lee, Marian D., Murthy, Hemant S. , Taylor, Richard A. , Franco, Pablo Moreno , Menser, Terri

Otolaryngology–Head and Neck Surgery | October 13, 2024 | Volume: 171 | Issue: 6 | Pages: 1925-1927

10.1002/ohn.1015 Get It

AbstractNational performance metrics ultimately enhance patient decision‐making and promote meaningful improvements in health care delivery, which makes having valid and reliable measures essential. This study examined US News and World Report metrics from 2019 to 2012 and used electronic health record data, combined with detailed chart review across 3 in‐system hospitals, to assess the provision of care compared to the attribution of patients assigned to the ear, nose, and throat (ENT) mortality group. Of the initial 47 ENT‐attributed deaths, 23 of those were verified, dimensioning the mortality rate from 1.7% to just 0.8%. These results underscore the necessity of rethinking measures and mortality attribution methodologies to be more accurate. Current methods use Medicare Severity Diagnosis Related Group billing coding to map the attribution. We suggest transitioning away from specialty ranking approaches and towards a procedure and condition “rating” approach to ensure that these ranking types capture data about the provision of care within a given encounter.
Adding an extension piece to the end of the purge side arm of the Impella device can prevent the incidence of the cassette breaking and decrease the Impella device failure rate: Impact of practice change on patient outcome
SATASHIA, PARTHKUMAR , White, Andrew D. , Isha, Shahin , Hanson, Abby , Jenkins, Anna , Blasavage, Jessica, Matos, Nikki , Tomlinson, Amanda, Zhang, Stephanie , Quiñones, Quintin J., Waldron, Nathan H. , Kiley, Sean , Chaudhury, Sanjay, Shapiro, Anna B, Sanghavi, Devang , White, Andrew , Quinones, Quintin, Waldron, Nathan, Guru, Pramod K , Sanghavi, Devang K., Jenkins, Anna S , Shahin, Isha , White, Andrew, Bhattacharyya, Anirban , Guru, Pramod , Franco, Pablo Moreno

Perfusion | December 7, 2023 | Volume: 39 | Issue: 8 | Pages: 1757-1760

10.1177/02676591231220305 Get It

Background: Impella 5.5® with Smart Assist is a minimally invasive Left Ventricular Assist Devices (LVAD) approved by the Food and Drug Administration (FDA) for treating ongoing cardiogenic shock for up to 14 days. The Impella® intends to reduce ventricular workload and provide the circulatory support necessary for myocardial recovery. Research Question: Compared to standard practice, does adding an extension piece to the purge tube side arm of the Impella® Device decrease the incidence of device failure and positively impact the health outcome of adult patients receiving Impella® support? Study Design and Methods: A retrospective chart review of ICU patients was done at a tertiary care center from August 2018 to August 2022 to assess the differences in patient outcomes related to Impella® Device utilization before and after the implementation of the extension piece to the purge tube sidearm. Among patients reviewed, a total of 20 were included in our review, with seven not having the purge tube side arm extension added, while 13 patients had the extension. Results: The two study groups had no significant difference in patient health outcomes. Additionally, there were no instances of device failure requiring explanation without the extension tubing. However, there were no cases of the purge cassette cracking with the addition of the extension tubing. Conclusion: The addition of extension tubing to the purge cassette of the Impella® Device did not impact patient health outcomes or the incidence of device failure. There was a complete reduction in the incidence of the purge cassette cracking, which could reduce the potential for infection or device failure over a long period of mechanical support. There is a need for long-term prospective studies to confirm the results.
Outcomes of adult patients supported by extracorporeal membrane oxygenation (ECMO) following cardiopulmonary arrest. The Mayo Clinic experience
Guru, Pramod , Seelhammer, Troy G. , Singh, Tarun D. , Sanghavi, Devang , Chaudhary, Sanjay , Riley, Jeffrey B., Friedrich, Tammy, Stulak, John M., Haile, Dawit T. , Schears, Gregory J. , Guru, Pramod K , Sanghavi, Devang K., Chaudhary, Sanjay , Kashyap, Rahul

Journal of Cardiac Surgery | July 12, 2021 | Volume: 36 | Issue: 10 | Pages: 3528-3539

10.1111/jocs.15804 Get It

Delayed renal transplant failure secondary to renal vein thrombosis in a patient with a permanent IVC filter
Lewis, K.L. , Wadei, Hani M. , Guru, Pramod , LEWIS, KRISTYN L, Guru, Pramod K , Wadei, Hani M , Patel, Payal Mukesh

BMJ Case Reports | March 29, 2021 | Volume: 14 | Issue: 3 | Pages: e236619

10.1136/bcr-2020-236619 Get It

Renal vein thrombosis is a rare, but potentially serious complication in patients with renal transplantation as it can lead to non-reversible graft injury and failure. Often this clinical entity is found in the early transplantation period, and the available management strategies are associated with favourable patient outcomes. The incidence, pathophysiology and outcomes for the delayed occurrence of renal vein thrombosis are unknown. The case here describes a unique situation with an excellent clinical outcome related to early diagnosis and appropriate care.
Heparin vs bivalirudin anticoagulation for extracorporeal membrane oxygenation
Kaseer, Haya , Soto‐Arenall, Matthew, Sanghavi, Devang , Moss, John, Ratzlaff, Robert A. , Pham, Si M. , Guru, Pramod , Ratzlaff, Robert, Pham, Si , Guru, Pramod K , Kaseer, Haya S , Moss, John E.

Journal of Cardiac Surgery | February 12, 2020 | Volume: 35 | Issue: 4 | Pages: 779-786

10.1111/jocs.14458 Get It

Postoperative Pulmonary Edema Conundrum: A Case of Negative Pressure Pulmonary Edema
Guru, Pramod , Agarwal, Anjali , Pimentel, Mario, Guru, Pramod K , McLaughlin, Diane C, McLaughlin, Diane , Bansal, Vikas

Case Reports in Critical Care | September 23, 2018 | Volume: 2018 | Issue: No issue available | Pages: 1-3

10.1155/2018/1584134 Get It

Postobstructive pulmonary edema (POPE) also known as negative pressure pulmonary edema (NPPE) is an underdiagnosed entity in clinical practice and can lead to life-threatening hypoxemia. A 64-year-old male patient’s perioperative course was complicated by acute hypoxemic respiratory failure, after extubation following general anesthesia, following the excision of the right vocal cord papilloma. His chest X-ray showed features of pulmonary edema, EKG showed dynamic ST-T changes in the lateral leads, and echocardiography showed evidence of regional motion abnormalities. His coronaries were normal on the immediate angiogram. He was managed with lung protective mechanical ventilation strategy, diuretics, and fluid restriction. His respiratory status improved, and trachea was extubated after 10 hours of intensive care unit (ICU) stay. The case illustrates the various differentials of immediate postoperative flash pulmonary edema and ensuing appropriate management strategy.