Back to Authors

Crawford, Daniel A

0000-0003-4577-1063

Mayo Clinic

1 University of Arizona College of Medicine-Phoenix, Phoenix, AZ, USA.

Citations 5

Liver Transplant Anatomy: Basics for Interventional Radiologists
Patel, Indravadan , Naidu, Sailendra , Wallace, Alex , Knuttinen, Grace , Alzubaidi, Sadeer , Özen, Merve , Crawford, Daniel A , Crawford, Daniel , Wallace, Alex, Öklü, Rahmi

Seminars in Interventional Radiology | February 4, 2025 | Volume: 42 | Issue: 02 | Pages: 234-238

10.1055/s-0045-1802649 Get It

AbstractLiver transplantation is becoming increasingly common in the United States, with very favorable 1- and 5-year survival rates. With increasing long-term survival rates, postprocedural vascular complications can occur with increased frequency. Familiarity with posttransplant vascular anatomy is essential for interventional radiologists dealing with this patient population. This article discusses the posttransplant venous, arterial, and biliary anatomy and the implications for minimally invasive interventions.
Unveiling Portal Vein Anatomy: Clinical Impact and Significance of Variants in Transjugular Intrahepatic Portosystemic Shunt Creation
Yancey, Kristina , Ruddy, Liane, Simmons, Curtis , Alzubaidi, Sadeer , Naidu, Sailen G., Özen, Merve , Crawford, Daniel A , Naidu, Sailen, Crawford, Daniel , Naidu, Sailendra

Seminars in Interventional Radiology | January 29, 2025 | Volume: 42 | Issue: 02 | Pages: 156-165

10.1055/s-0045-1802347 Get It

AbstractAn in-depth understanding of portal venous anatomy, particularly its variants, is essential for interventional radiologists performing complex hepatobiliary procedures such as transjugular intrahepatic portosystemic shunt (TIPS) creation. Anatomical variations in the portal venous system occur in approximately 35% of the population, and failure to identify these variants can result in significant procedural complications including vascular injury and postprocedural liver failure. This article discusses the most common (types I–V) portal vein variants and the importance of their preprocedural identification, their potential impact on procedural outcomes, and the role of advanced imaging techniques in mitigating risks associated with these anatomical variations.
Important Anatomy in Lymphatic Interventions: A Practical Review
Patel, Indravadan , Naidu, Sailendra , Wallace, Alex, Özen, Merve , Alzubaidi, Sadeer , Crawford, Daniel A , Crawford, Daniel

Seminars in Interventional Radiology | January 29, 2025 | Volume: 42 | Issue: 02 | Pages: 133-138

10.1055/s-0045-1801877 Get It

AbstractNew understanding of the lymphatic system as well as increasing recognition of its importance in various pathologies have increased the opportunity to perform lymphatic interventions. Advancement in our understanding of the lymphatic system anatomy, including variations, combined with improved imaging has renewed interest in both surgical and interventional management of a wide range of complex lymphatic pathologies. It is important for the proceduralist to recognize the anatomy, variability, and physiology of the lymphatic system, including lower extremity lymphatic drainage, cisterna chyli location, and thoracic duct drainage. The purpose of this study is to convey the practical aspects of performing lymphatic interventions in an effort to improve the speed and reliability of these procedures.
Bland Embolization of Benign Liver Tumors: Review of the Literature and a Single Center Experience
Crawford, Daniel , Naidu, Sailen G., Patel, Indravadan , Knuttinen, Grace , Alzubaidi, Sadeer , Öklü, Rahmi , Naidu, Sailen, Oklu, Rahmi , Crawford, Daniel A , Naidu, Sailendra

Journal of Clinical Medicine | February 12, 2021 | Volume: 10 | Issue: 4 | Pages: 658

10.3390/jcm10040658 Get It

Transarterial embolization has shown promise as a safe, effective, and less invasive treatment modality for benign liver lesions (hemangioma, focal nodular hyperplasia (FNH), and hepatic adenoma (HA)) with fewer complications compared to surgical intervention. There is no consensus regarding the most appropriate embolization material(s) for the treatment of benign liver tumors. The purpose of this study was to review the current literature regarding the transarterial embolization of benign liver tumors and to share our single center experience. This was a non-blinded, retrospective, single-institution review of the bland embolization of benign liver tumors. Clinical data and imaging before and after embolization were used to evaluate lesion response to transarterial embolization. Twelve patients were included in the study. Five patients with six hemangiomas were treated. Pain was a presenting complaint in all five of these patients. The median change in tumor volume was −12.4% and ranged from −30.1% to +42.3%. One patient with two FNH lesions was treated, and both lesion volumes decreased by more than 50%. Six patients with 10 adenomas were treated. Pain was a presenting complaint in three patients, and five patients had a lesion >5 cm. The median change in tumor volume was −67.0% and ranged from −92.9% to +65.8%. Bland transarterial embolization of liver hemangiomas, FNH, and HA can be an effective and minimally invasive treatment modality to control the size and/or symptoms of these lesions. There is a variable response depending on tumor type and the embolization materials used.
Endovascular Retrieval of an Embolized Atrial Septal Occluder Device From the Abdominal Aorta
Crawford, Daniel , Naidu, Sailen G., Davila, Victor J. , Stone, William M., Crawford, Daniel A , Naidu, Sailendra , Shah, Adil A.

Vascular and Endovascular Surgery | July 29, 2018 | Volume: 52 | Issue: 8 | Pages: 669-673

10.1177/1538574418790393 Get It

Patent foramen ovale (PFO) is a common heart condition in adults. Closure with a septal occluder device is a safe, well-established treatment option with excellent clinical outcomes. One rare complication of percutaneous PFO closure is embolization of the device to the heart chambers or distal vasculature. Most device migrations are recognized during or shortly after implantation. While many endovascular retrievals of migrated devices are successful, there are still a high percentage of surgical interventions performed. We report a case of a septal occluder device that embolized to the abdominal aorta and was discovered 7 days after implantation. Endovascular techniques with a snare and endobronchial forceps were used to retrieve the device safely.