Back to Authors

Al-Khalidi, Hussein R

Mayo Clinic

From the Duke Clinical Research Institute, Durham, NC (P.L.H., A.S.H., E.D.P., G.D.S., H.R.A.-K., L.H.C., B.G.H., P.H.P., K.J.A., S.M.A.-K.); Department of Medicine, Duke University Medical Center, Durham, NC (P.L.H., A.S.H., E.D.P., P.H.P., S.M.A.-K.); De

Citations 2

Primary Prevention Implantable Cardioverter-Defibrillators in Older Racial and Ethnic Minority Patients
Hellkamp, Anne S., Curtis, Lesley H. , Hammill, Stephen C., Masoudi, Frederick A. , Bhatt, Deepak L. , Al‐Khalidi, Hussein R. , Heidenreich, Paul A. , Anstrom, Kevin J. , Fonarow, Gregg C. , Pokorney, Sean D, Yancy, Clyde W. , Al-Khalidi, Hussein R, Al-Khatib, Sana M, Pokorney, Sean D. , Peterson, Eric D. , Al‐Khatib, Sana M. , Bhatt, Deepak L

Circulation: Arrhythmia and Electrophysiology | December 13, 2014 | Volume: 8 | Issue: 1 | Pages: 145-151

10.1161/circep.114.001878 Get It

Background— Racial and ethnic minorities are under-represented in clinical trials of primary prevention implantable cardioverter-defibrillators (ICDs). This analysis investigates the association between primary prevention ICDs and mortality among Medicare, racial/ethnic minority patients. Methods and Results— Data from Get With The Guidelines-Heart Failure Registry and National Cardiovascular Data Registry’s ICD Registry were used to perform an adjusted comparative effectiveness analysis of primary prevention ICDs in Medicare, racial/ethnic minority patients (nonwhite race or Hispanic ethnicity). Mortality data were obtained from the Medicare denominator file. The relationship of ICD with survival was compared between minority and white non-Hispanic patients. Our analysis included 852 minority patients, 426 ICD and 426 matched non-ICD patients, and 2070 white non-Hispanic patients (1035 ICD and 1035 matched non-ICD patients). Median follow-up was 3.1 years. Median age was 73 years, and median ejection fraction was 23%. Adjusted 3-year mortality rates for minority ICD and non-ICD patients were 44.9% (95% confidence interval [CI], 44.2%–45.7%) and 54.3% (95% CI, 53.4%–55.1%), respectively (adjusted hazard ratio, 0.79; 95% CI, 0.63–0.98; P =0.034). White non-Hispanic patients receiving an ICD had lower adjusted 3-year mortality rates of 47.8% (95% CI, 47.3%–48.3%) compared with 57.3% (95% CI, 56.8%–57.9%) for those with no ICD (adjusted hazard ratio, 0.75; 95% CI, 0.67%–0.83%; P <0.0001). There was no significant interaction between race/ethnicity and lower mortality risk with ICD ( P =0.70). Conclusions— Primary prevention ICDs are associated with lower mortality in nonwhite and Hispanic patients, similar to that seen in white, non-Hispanic patients. These data support a similar approach to ICD patient selection, regardless of race or ethnicity.
Survival After Primary Prevention Implantable Cardioverter-Defibrillator Placement Among Patients With Chronic Kidney Disease
Hess, Paul L. , Hellkamp, Anne S., Sanders, Gillian D, Al‐Khalidi, Hussein R. , Curtis, Lesley H. , Pun, Patrick H. , Curtis, Jeptha P. , Anstrom, Kevin J. , Hammill, Stephen C., Al-Khalidi, Hussein R, Hammill, Bradley G, Al-Khatib, Sana M, Peterson, Eric D. , Hammill, Bradley G. , Al‐Khatib, Sana M.

Circulation: Arrhythmia and Electrophysiology | July 19, 2014 | Volume: 7 | Issue: 5 | Pages: 793-799

10.1161/circep.114.001455 Get It

Background— Guidelines recommend that implantable cardioverter-defibrillator (ICD) candidates have an estimated longevity of ≥1 year. Longevity can be affected by chronic kidney disease (CKD). Methods and Results— Using the National Cardiovascular Data Registry ICD registry linked with the Social Security Death Master File, we assessed the rate of death after primary prevention ICD placement between January 1, 2006, and December 31, 2007, according to CKD stage. Using Cox models, we identified factors associated with death among patients with CKD. Compared with patients without CKD (n=26 056), those with CKD (n=21 226) were older, less commonly men, more often white, and more frequently had comorbid illness. Compared with patients without CKD, patients with a glomerular filtration rate 30 to 60, glomerular filtration rate <30, and end-stage renal disease on dialysis had a higher risk of death after ICD placement (hazard ratio, 2.08; 95% confidence interval, 1.99–2.18; P <0.0001; hazard ratio, 4.20; 95% confidence interval, 3.92–4.50; P <0.0001; and hazard ratio, 4.80; 95% confidence interval, 4.46–5.17; P <0.0001, respectively). Corresponding 1-year death rates were 4.4%, 9.1%, 20.2%, and 22.4%. Among patients with CKD, factors associated with increased risk of death included CKD severity, age >65 years, heart failure symptoms, diabetes mellitus, lung disease, serum sodium <140 mEq/L, atrial fibrillation or flutter, and a lower ejection fraction. Conclusions— The risk of death after primary prevention ICD placement is proportional to CKD severity. Among patients with CKD, several factors are prognostically significant and could inform clinical decision making on primary prevention ICD candidacy.