Abstract Dementia with Lewy bodies (DLB) research has seen a significant growth in international collaboration over the last three decades. However, researchers face a challenge in identifying large and diverse samples capable of powering longitudinal studies and clinical trials. The DLB research community has begun to focus efforts on supporting the development and harmonization of consortia, while also continuing to forge networks within which data and findings can be shared. This article describes the current state of DLB research collaborations on each continent. We discuss several established DLB cohorts, many of whom have adopted a common framework, and identify emerging collaborative initiatives that hold the potential to expand DLB networks and diversify research cohorts. Our findings identify geographical areas into which the global DLB networks should seek to expand, and we propose strategies, such as the creation of data‐sharing platforms and the harmonization of protocols, which may further potentiate international collaboration.
Cognitive profile of LRRK2‐related Parkinson's disease
BackgroundThe cerebrospinal fluid (CSF) biomarkers amyloid β (Aβ)‐42, total‐tau (T‐tau), and phosphorylated‐tau (P‐tau) demonstrate good diagnostic accuracy for Alzheimer's disease (AD). However, there are large variations in biomarker measurements between studies, and between and within laboratories. The Alzheimer's Association has initiated a global quality control program to estimate and monitor variability of measurements, quantify batch‐to‐batch assay variations, and identify sources of variability. In this article, we present the results from the first two rounds of the program.MethodsThe program is open for laboratories using commercially available kits for Aβ, T‐tau, or P‐tau. CSF samples (aliquots of pooled CSF) are sent for analysis several times a year from the Clinical Neurochemistry Laboratory at the Mölndal campus of the University of Gothenburg, Sweden. Each round consists of three quality control samples.ResultsForty laboratories participated. Twenty‐six used INNOTEST enzyme‐linked immunosorbent assay kits, 14 used Luminex xMAP with the INNO‐BIA AlzBio3 kit (both measure Aβ‐(1‐42), P‐tau(181P), and T‐tau), and 5 used Meso Scale Discovery with the Aβ triplex (AβN‐42, AβN‐40, and AβN‐38) or T‐tau kits. The total coefficients of variation between the laboratories were 13% to 36%. Five laboratories analyzed the samples six times on different occasions. Within‐laboratory precisions differed considerably between biomarkers within individual laboratories.ConclusionsMeasurements of CSF AD biomarkers show large between‐laboratory variability, likely caused by factors related to analytical procedures and the analytical kits. Standardization of laboratory procedures and efforts by kit vendors to increase kit performance might lower variability, and will likely increase the usefulness of CSF AD biomarkers.