Spatial Differences in Cellular and Molecular Responses as a Function of the Material Used in Conduit‐Mediated Repair and Autograft Treatment of Peripheral Nerve Injuries
AbstractThe treatment of peripheral nerve injuries remains a major problem worldwide despite the availability of a number of Food and Drug Administration (FDA) approved devices which fail to match the efficacy of autografts. Different strategies are used to improve regeneration and functional recovery using biomaterial nerve conduits. However, there is little investigation of the transcriptomic and proteomic changes which occur as a result of these interventions, particularly regarding transection injuries. This study explores differences between autograft‐mediated repair and conduit‐material‐mediated repair of peripheral nerve injuries to understand fundamental differences in their repair mechanisms at the proteomics level at the proximal, middle, and distal components in the early stages of repair. Pathway analysis demonstrates that each material selectively activates different regenerative pathways and alters different biological functions spatially throughout the biomaterial conduits. The analysis highlights some of the deficiencies in conduit‐mediated repair in comparison to autograft (e.g., recycling of myelin and cholesterol, reduction in reactive oxygen species, and higher expression of regenerative proteins). These findings thus suggest that by supplementing the expression of these proteins on the biomaterial of choice, this study can potentially attain regeneration equivalent to autograft. This approach paves the way for incorporating future biomaterial‐specific functionalities in nerve guidance conduits.
Quantitative evaluation of movement and strength of the upper limb after transection of the C-7 nerve: is it possible in an animal model?
Object Contralateral C-7 nerve transfer has been used clinically for more than 20 years. The increased interest in studies of transfer effectiveness at different target muscles, posttransfer cocontraction, and brain plasticity has prompted the need for an animal model. In addition to the conventional electrophysiological, histomorphometric, and biomechanical evaluation modalities, quantitative functional and behavioral evaluation will be crucial in applying this kind of model. The aim of this study was to establish a C-7 transection animal model and quantify the changes in upper-limb joint movement and muscle power. Methods A C-7 nerve transection model was created in Sprague-Dawley rats, the brachial plexus of which resembles the human brachial plexus. The impact of C-7 transection on donor limb function—namely, strength, movement, and coordination—was evaluated in 6 rats. Muscle strength (power reported in g) was measured as a grasping task. The active range of motion (ROM; angle reported in °) of the elbow, wrist, and metacarpophalangeal joints was quantified by computerized video motion analysis. Antiresistance coordinated movement (speed reported in seconds) was assessed by the vertical rope-climbing test. These tests were carried out before surgery and at 2, 4, 6, 8, 10, 14, 21, and 28 days after C-7 transection. Repeated-measures 1-way analysis of variance was applied for statistical analysis. When the overall probability value was < 0.05, the Dunnett multiple-comparison posttest was used to compare postoperative values with preoperative baseline values. Results Immediately after C-7 transection, the mean ± SD grip strength declined from 378.50 ± 20.55 g to 297.77 ± 15.04 g. Active elbow extension was impaired, as shown by a significant decrease of the elbow extension angle. The speed of vertical rope climbing was also reduced. Elbow flexion, wrist flexion and extension, and metacarpophalangeal joint flexion and extension were not impaired. Fast recovery of motor function was observed thereafter. Grip strength, range of active elbow extension, and speed of rope climbing returned to baseline values at postoperative Days 4, 8, and 8, respectively. Conclusions The ROM and muscle strength of the upper limb in rats can be measured quantitatively in studies that simulate clinical situations. Application of these functional evaluation modalities in a C-7 nerve transection rat model confirmed that transection of C-7 causes only temporary functional dysfunction to the donor limb. The results obtained in this animal model mimic those seen in humans who undergo contralateral C-7 nerve harvesting.