Back to Authors

Arenas-Martinez, Josealberto

Mayo Clinic

Mayo Clinic in Arizona

Citations 1

P1.026. Diagnostic Yield of Esophagram Compared to Gold Standard Ambulatory Reflux Monitoring for Detection of Gastroesophageal Reflux Disease
Vela, Anika, Arenas-Martinez, Josealberto, Crowell, Michael, Ramirez, Francisco, Vela, Marcelo, Wang, Fangfang, Arenas-Martinez, Josealberto Sebastiano , Crowell, Michael D. , Vela, Marcelo F.

Diseases of the Esophagus | August 22, 2026 | Volume: 39 | Issue: Supplement_1 | Pages: No page available

10.1093/dote/doag077.174 Get It

Abstract Topic Benign Disease: Gastro-Esophageal Reflux and Hiatal Hernia Background Ambulatory reflux monitoring (wireless pH or catheter-based pH-impedance) performed off acid suppression is the gold standard for diagnosing gastroesophageal reflux disease (GERD). Barium esophagram (BE), commonly used to evaluate esophageal symptoms, routinely assesses reflux, yet its diagnostic accuracy relative to ambulatory monitoring remains unclear. Existing studies are limited, relied on outdated reflux criteria, and demonstrated poor concordance with BE-based GERD diagnoses. We aimed to determine whether BE reliably identifies GERD compared with ambulatory reflux monitoring interpreted using updated Lyon 2.0 consensus criteria. Methods Retrospective analysis of adult patients that underwent BE and ambulatory reflux monitoring (wireless pH or pH-impedance) off PPI within an 8-month interval. Patients with a history of fundoplication were excluded. Esophagram was performed with standard technique and reported by radiology, considered positive for GERD if there was reflux above the thoracic inlet with or without provocative maneuvers. Reflux monitoring studies were considered positive or negative for GERD based on Lyon consensus 2.0 recommendations. Inter-rater reliability, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and received operating characteristic (ROC) curve analysis were calculated for esophagram, with reflux monitoring diagnosis as the gold standard. Results 64 patients were included, 31 % male, mean age = 60 years, mean Body Mass Index = 26. GERD was diagnosed by esophagram in 20 patients (31%), and by reflux monitoring in 19 (30%). Compared to reflux monitoring, BE had sensitivity: 47%, specificity: 76%, PPV: 45%, NPV: 77%, and area under the ROC curve: 0.61 (Figure 1). Inter-rater reliability between BE and ambulatory reflux monitoring was poor (Cohen's Kappa = 0.226). Conclusion There was poor concordance between BE and ambulatory reflux monitoring for diagnosing GERD. BE overall had suboptimal diagnostic performance, with low sensitivity, and moderate specificity. Furthermore, the area under the ROC curve indicates limited ability to distinguish correctly between patients with and without GERD. These findings indicate that barium esophagram should not be relied upon as a diagnostic tool for GERD.