Back to Authors

Tint, Hlaing

https://orcid.org/0000-0002-3091-4175

Mayo Clinic

Department of Pathology and Laboratory Medicine McGovern Medical School Houston Texas USA

Citations 2

Inter‐institutional perspectives on usage of fibrinogen replacement therapies in North America
Tay, Cindy , Stephens, Laura D. , Lu, Wen , O'Brien, Kerry , Tint, Hlaing , Eichbaum, Quentin , Stephens, Laura , Lu, Wen

Vox Sanguinis | September 15, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/vox.70374 Get It

Abstract Background and Objectives Cryoprecipitated antihemophilic factor (cryoprecipitate), fibrinogen concentrate (FC), and pathogen‐reduced cryoprecipitated fibrinogen complex (PR cryoprecipitate) are sources of fibrinogen replacement, and each has advantages and disadvantages in terms of cost, efficacy, safety, and logistics of administration. This study examines the respective utilization frequencies of these different products at institutions in North America and the factors influencing the decision on which one(s) to adopt. Materials and Methods A survey was distributed via email to contacts for Advancement of Blood and Biotherapies (AABB)‐accredited blood banks/transfusion services. Survey questions covered topics including the availability and usage of FC, cryoprecipitate, and PR cryoprecipitate, as well as the perceived advantages of each product. Results A total of 53 responses were received from surveyed institutions (estimated 25% response rate). Over half (31/53, 58.5%) of respondents exclusively used cryoprecipitate, 30.2% (16/53) used two sources of fibrinogen replacement, and 7.5% (4/53) used all three (cryoprecipitate, FC, and PR cryoprecipitate). More than half of the institutions restricted FC to specific indications, primarily for cost containment. The most commonly cited advantages of FC over cryoprecipitate were storage convenience and rapid reconstitution. Conclusion Surveyed institutions in the United States and Canada primarily use cryoprecipitate for fibrinogen replacement, with variable usage of FC and limited usage of PR cryoprecipitate. The perception of FC being more expensive than cryoprecipitate predominated. Further studies comparing available fibrinogen replacement options would be valuable, particularly with consideration of product acquisition cost, wastage, impacts on utilization of other blood products, and patient outcomes.
Cold and Room-Temperature Platelets in Cardiac Surgery
Spinella, Philip C., Zantek, Nicole D., Nicolson, Susan C., Khanna, Ashish K., Boisen, Michael L., Williams, Tiffany M. , Monteleone, Matthew, Pavey, Warren, Smith, Bradford B., Ahmed, M. Iqbal, Jeng, Eric, Flynn, B S, Joshi, Ravi V. , Preuss, James , Goswami, Dheeraj, Lewis, Choy, Tint, Hlaing , Kwak, Jenny , Sodha, Neel, Simon, Eric R. , Van, Philbert Y., Greilich, Philip E. , Booth, Frank V. McL., Carter, Camille, Keegan, Anastazia , Cap, Andrew P., Matuk, James, McGlothlin, Anna, Berry, Nicholas , Lewis, Roger , Steiner, Marie E., Group, CHIPS Investigator, Hu, Paula, Hawkins, Jaleah, Jobes, David R. , Fadeyi, Emmanuel A. , Reynolds, Abigail M.A., Bell, Carter G., Gandhi, Manish J., Montonye, Beth, Serna-Gallegos, Derek, Sultan, Ibrahim, Kinney, Stephanie , Molony, Kathleen, Hensch, Lisa, Resheidat, Ashraf, Malivers, Martine, Hahn, Rebbecca, Viellez, Annette Le, Pepperell, Dominic , Lu, Qun, Downey, Frank, Haeger, Kayla N., Baltagi, Sirine , Jaquiss, Robert D.B., Noland, Daniel K., Cole, Regina, Duffin, Aspen, Scott, John P., Zeng, Long, Ballew, Angie, Webb, Christopher, Jessen, Michael, Hopson, Erryn, Mickle, Peri, Kavanagh, Simon, Matzelle, Shannon, Mennie, Colleen, Davenport, Robertson, Chlebeck, Therese, Zenk, Emmy, Lotz, Daniel T., Choi, Warren , Hobbs, Rhonda, Baptise, Amanda, DeChristopher, Phillip, Schoenecker, Nancy, Rodheim, Dianna, Connor, Joseph, Griese, Daniel J., McGuire, Erin, VanSandt, Mandy, Sera, Valerie, O’Donovan, Justine , Marks, Denese, Johnson, Lacey, Viele, Kert , Cholette, Jill M., Selke, Frank, Silverman, Toby, Shea, Susan, Yazer, Mark, Young, P. J., Ness, Paul Van, Dean, J. Michael, Shaz, Beth, Stubbs, James, Klompas, Allan M. , Spinella, Philip C. , Zantek, Nicole D. , VanBuren, John M. , Nicolson, Susan Craig , Khanna, Ashish K. , Boisen, Michael L , Monteleone, Matthew P., Bashir, Dalia A. , Pavey, Warren , Niebler, Robert A. , Jeng, Eric I-Hun , Goswami, Dheeraj , Yamada, Chisa , Lewis, Choy R., Cohn, Claudia S. , Sodha, Neel R. , Cap, Andrew , Matuk, James , Smith, Mark M. , Montonye, Beth L., Kaplan, Alesia , Kinney, Stephanie , Resheidat, Ashraf M., Downey, Francis X. , Ballew, Angie , Matzelle, Shannon A, Crowe, Liz , DeChristopher, Phillip J., Griese, Daniel, Sera, Valerie, Marks, Denese C. , Johnson, Lacey , Cholette, Jill M., Levy, Jerrold H. , Silverman, Toby , Yazer, Mark H. , Strandenes, Geir , Shaz, Beth H. , Stubbs, James R.

JAMA | August 17, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1001/jama.2026.13328 Get It

Importance Patients undergoing cardiac surgery with cardiopulmonary bypass often require platelet transfusions for bleeding. Platelets are routinely stored at room temperature (20-24 °C) for up to 5 to 7 days; however, cold storage (1-6 °C) may allow for increased storage duration without loss of hemostatic function. Objective To determine the maximum cold-storage duration, up to 21 days, for which cold-stored platelets (CSPs) are noninferior or superior in hemostatic efficacy to room-temperature platelets (RTPs) when transfused in actively bleeding patients undergoing cardiac surgery with cardiopulmonary bypass. Design, Setting, and Participants A phase 3, multicenter, randomized, partially blinded, adaptive, noninferiority, storage duration–ranging trial conducted in pediatric and adult patients undergoing cardiac surgery with planned cardiopulmonary bypass at 27 sites in the US and Australia from December 2021 to March 2025. Statistical analysis was conducted from September 9 to October 3, 2025. Intervention Patients were randomized 2:1 to receive CSPs with a maximum of 21 days of storage vs RTPs with a maximum of 7 days of storage. Main Outcomes and Measures The primary outcome was a hemostatic efficacy score with values ranging from 1 to 5 and higher values indicating greater bleeding. The noninferiority margin was 1 point. The success criterion was met if at least 1 cold-storage duration of 7 days or more had a posterior probability of noninferiority of at least 97.5%. The secondary outcome was 24-hour chest tube output. Results Of the 1000 patients who underwent platelet transfusion, 989 were included in the primary analysis (650 CSPs and 339 RTPs). The cohort had a mean (SD) age of 42.1 (30.1) years and 67.8% were male. CSPs were noninferior to RTPs for the primary outcome, with a probability of greater than 99.9% for all cold-storage durations. Pooled across storage durations, CSPs had a mean difference from RTPs of 0.09 (95% credible interval, −0.06 to 0.23). Median (IQR) chest tube output at 24 hours (8.9 mL/kg [5.2-15.4] for CSPs vs 8.4 mL/kg [5.5-15.9] for RTPs; difference in medians, 0.4 [95% CI, −1.0 to 1.5]) was not statistically different between study groups. In a post hoc analysis, as all storage durations were noninferior, considering the CSPs as a single group, the hemostatic efficacy score was similar between both groups: mean (SD) of 3.08 (1.15) CSPs vs 2.99 (1.10) RTPs. There were no differences in venous or arterial thrombotic events, transfusion-associated adverse events, acute respiratory distress syndrome, kidney failure, septic shock, and mortality between the study groups, except for increased reexploration rates in the CSP group. Conclusions and Relevance For patients undergoing cardiac surgery, CSPs stored up to 21 days are noninferior to RTPs for the control of active surgical bleeding. Use of CSPs may allow for increased availability of platelets by reducing wastage and shortages and may allow for incorporation of platelets into inventory at locations where platelets cannot be maintained due to the 5- to 7-day shelf life of RTPs. Trial Registration ClinicalTrials.gov Identifier: NCT04834414