Back to Authors

McLaren, Jay W.

https://orcid.org/0000-0002-2573-425X

Mayo Clinic

Mayo Clinic

Citations 13

Effect of Topical Phenylephrine 2.5% on Episcleral Venous Pressure in Normal Human Eyes
Kazemi, Arash , McLaren, Jay W. , Sit, Arthur J. , Sit, Arthur J

Investigative Opthalmology & Visual Science | October 10, 2021 | Volume: 62 | Issue: 13 | Pages: 4

10.1167/iovs.62.13.4 Get It

Confocal Microscopy Changes in Epithelial and Stromal Thickness up to 7 Years After LASIK and Photorefractive Keratectomy for Myopia
Erie, Jay C., McLaren, Jay W. , Bourne, William M., Patel, Sanjay V.

Journal of Refractive Surgery | December 28, 2018 | Volume: 23 | Issue: 4 | Pages: 385-392

10.3928/1081-597x-20070401-11 Get It

Purpose: To determine the long-term changes in epithelial, stromal, and corneal thickness after LASIK and photorefractive keratectomy (PRK). Methods: In two prospective observational case series, 11 patients (16 eyes) received LASIK and 12 patients (18 eyes) received PRK to correct myopia or myopic astigmatism. None of the corneas had retreatment procedures. Corneas were examined using confocal microscopy before and at 1 month, and at 1, 2, 3, 5, and 7 years after surgery. Central thicknesses were measured from reflected light intensity profiles recorded by confocal microscopy. Postoperative epithelial thickness was compared to preoperative, and postoperative stromal and corneal thicknesses were compared to thickness at 1 month after surgery. Results: In LASIK, epithelial thickness at 1 month (51±4 µ m, n=11) was greater than before surgery (41±4 µ m, n=16; P <.001) and remained thicker through 7 years (52±6 µ m, n=13; P <.001). Stromal and corneal thickness did not change between 1 month and 7 years after LASIK. After PRK, corneal thickness at 1 year (464±44 µ m, n=17) was greater than at 1 month (442±39 µ m, n=15; P =.001) and remained thicker at 7 years after PRK (471±45 µ m, n=17; P <.001). Conclusions: The early increase in central epithelial thickness after myopic LASIK persists for at least 7 years and is probably the result of epithelial hyperplasia. Central corneal thickness increases during the first year after PRK and remains stable thereafter up to 7 years. [ J Refract Surg . 2007;23:385–392.]
The Effects of Netarsudil Ophthalmic Solution on Aqueous Humor Dynamics in a Randomized Study in Humans
Kazemi, Arash , McLaren, Jay W. , Kopczynski, Casey , Heah, Theresa, Novack, Gary D. , Sit, Arthur J. , Sit, Arthur J

Journal of Ocular Pharmacology and Therapeutics | February 22, 2018 | Volume: 34 | Issue: 5 | Pages: 380-386

10.1089/jop.2017.0138 Get It

Corneal Optical Changes Associated with Induced Edema in Fuchs Endothelial Corneal Dystrophy
Wacker, Katrin , McLaren, Jay W. , Kane, Katrina M., Patel, Sanjay V.

Cornea | December 4, 2017 | Volume: 37 | Issue: 3 | Pages: 313-317

10.1097/ico.0000000000001465 Get It

Purpose: Patients with Fuchs endothelial corneal dystrophy (FECD) often notice poor vision in the morning that improves as the day progresses. In this study, we determined changes in corneal optical properties associated with induced corneal edema. Methods: Twenty-three phakic eyes (23 participants) with FECD (grades 1–6, modified Krachmer scale) and 8 normal eyes (8 participants) were examined by Scheimpflug photography. Central corneal thickness, high-order aberrations from anterior and posterior corneal surfaces, and backscatter from the anterior, mid-, and posterior cornea were determined from the Scheimpflug images. A low-oxygen permeable contact lens was placed on the eye, and eyes were closed for 2 hours, after which the lens was removed and Scheimpflug photography was repeated for up to 5 hours to determine changes in backscatter and high-order aberrations. Results: Corneas swelled by 10% [95% confidence interval (CI), 9–10]. Backscatter from the anterior cornea increased by 416 scatter units (SU, 95% CI, 344–488; P < 0.001), independent of the presence and severity of FECD. Recovery of anterior backscatter was slower in advanced FECD (81 SU/h, 95% CI, 60–120) compared with normal (123 SU/h, 95% CI, 95–150; P = 0.019). Anterior and posterior corneal high-order aberrations, and mid and posterior backscatter, did not increase with induced swelling. Conclusions: Inducing corneal edema increases anterior corneal backscatter but not high-order aberrations. Subjective poor vision in the morning in FECD is probably caused by scattered light rather than by high-order aberrations, suggesting that these patients experience more disability glare than decreased visual acuity.
Effect of Body Position on Epsicleral Venous Pressure in Healthy Subjects
Arora, Nitika, McLaren, Jay W. , Hodge, David O. , Sit, Arthur J. , Sit, Arthur J

Investigative Opthalmology & Visual Science | October 6, 2017 | Volume: 58 | Issue: 12 | Pages: 5151

10.1167/iovs.17-22154 Get It

In Vivo Noninvasive Measurement of Young’s Modulus of Elasticity in Human Eyes: A Feasibility Study
Sit, Arthur J. , Lin, Shuai-Chun, Kazemi, Arash, McLaren, Jay W. , Pruet, Christopher M. , Zhang, Xiaoming , Zhang, Xiaoming , Kazemi, Arash, Sit, Arthur J

Journal of Glaucoma | August 29, 2017 | Volume: 26 | Issue: 11 | Pages: 967-973

10.1097/ijg.0000000000000774 Get It

Purpose: Abnormal ocular biomechanical properties may be important for understanding the risk of glaucoma. However, there are no clinical methods for measuring standard material properties in patients. In this feasibility study we demonstrated proof-of-principle for a novel method, ultrasound surface wave elastography (USWE), to determine the in vivo Young’s modulus of elasticity of corneas in normal human eyes. Methods: In total, 20 eyes of 10 healthy subjects (mean age, 51.4±7.2; ±SD; range, 43 to 64 y) were studied. A spherical-tipped probe (3-mm diameter) was placed on closed eyelids and generated a gentle harmonic vibration at 100 Hz for 0.1 second. Wave speed propagation in the cornea was measured by USWE, and Young’s modulus was calculated from the wave speed. Associations between Young’s modulus and intraocular pressure (IOP), age, central corneal thickness, and axial length were explored by the Pearson correlation. Statistical significance was determined by using generalized estimating equation models to account for possible correlation between fellow eyes. Results: Mean IOP was 12.8±2.7 mm Hg. Mean wave speed in the cornea was 1.82±0.10 m/s. Young’s modulus of elasticity was 696±113 kPa and was correlated with IOP (r=0.57; P=0.004), but none of the other variables (P>0.1). Conclusions: USWE is a novel noninvasive technique for measuring ocular biomechanical properties. Corneal Young’s modulus in normal eyes is associated with IOP, consistent with measurements in cadaver eyes. Further work is needed to determine elasticity in other ocular tissues, particularly the sclera, and if elasticity is altered in glaucoma patients.
Comparison of Aqueous Outflow Facility Measurement by Pneumatonography and Digital Schiøtz Tonography
Kazemi, Arash , McLaren, Jay W. , Lin, Shuai-Chun, Gulati, Vikas , Moroi, Sayoko E. , Sit, Arthur J. , Toris, Carol B. , Moroi, Sayoko E , Sit, Arthur J

Investigative Opthalmology & Visual Science | January 23, 2017 | Volume: 58 | Issue: 1 | Pages: 204

10.1167/iovs.16-20754 Get It

Corneal Hydration Control in Fuchs' Endothelial Corneal Dystrophy
Wacker, Katrin , McLaren, Jay W. , Kane, Katrina M., Baratz, Keith H. , Patel, Sanjay V. , Patel, Sanjay V

Investigative Opthalmology & Visual Science | September 23, 2016 | Volume: 57 | Issue: 11 | Pages: 5060

10.1167/iovs.16-20205 Get It

Circadian Variation of Aqueous Humor Dynamics in Older Healthy Adults
Nau, Cherie B. , Malihi, Mehrdad, McLaren, Jay W. , Hodge, David O. , Sit, Arthur J. , Sit, Arthur J

Investigative Opthalmology & Visual Science | September 27, 2013 | Volume: 54 | Issue: 12 | Pages: 7623

10.1167/iovs.13-12690 Get It

Silica Hybrid for Corneal Replacement: Optical, Biomechanical, and Ex Vivo Biocompatibility Studies
DiVito, Michael D., Rudisill, Stephen G., Stein, Andreas , Patel, Sanjay V. , McLaren, Jay W. , Hubel, Allison , Patel, Sanjay V

Investigative Opthalmology & Visual Science | November 14, 2012 | Volume: 53 | Issue: 13 | Pages: 8192

10.1167/iovs.12-10561 Get It