Multi-Laboratory Evaluation of an Automated Microbial Detection/Identification System
Smith, P. B., Gavan, T L, Isenberg, Henry D., Sonnenwirth, Alex C., Taylor, Welton I., Washington, John A., Balows, Albert

Journal of Clinical Microbiology | June 2, 2021 | Volume: 8 | Issue: 6 | Pages: 657-666

10.1128/jcm.8.6.657-666.1978 Get It

An automated and computerized system (Automicrobic System [AMS]) for the detection of frequently encountered bacteria in clinical urine specimens was tested in a collaborative study among six laboratories. The sensitivity, specificity, reliability, and reproducibility of the AMS were determined, and the system was compared with conventional detection and identification systems. In this study, pure cultures and mixtures of pure cultures were used to simulate clinical urine specimens. With pure cultures, the sensitivity of the AMS in identifying the nine groups of organisms most commonly found in urine averaged 92.8%. The specificity averaged 99.4%, and the reliability of a positive result averaged 92.1%. The latter value was strongly influenced by a relatively high occurrence of false positive Escherichia coli results. The AMS was capable of detecting growth of most organisms, including those which it was not designed to identify. However, it identified some of these incorrectly as common urinary tract flora. Reproducibility of results, both within laboratories and among different laboratories, was high. Fast-growing organisms, such as E. coli and Klebsiella/Enterobacter species, were detected often at cell populations well below the AMS enumeration threshold of 70,000/ml. In mixed culture studies, high levels of sensitivity and specificity were maintained but when Serratia species were present in mixtures with other organisms, there was often a false positive report of E. coli. The overall performance of the AMS was considered satisfactory under the test conditions used.
Interpretation of the Disk Diffusion Susceptibility Test for Amikacin: Report of a Collaborative Study
Washington, John A., Yu, Pauline K. W., Gavan, T L, Schoenknecht, Fritz D., Thornsberry, Clyde

Antimicrobial Agents and Chemotherapy | June 27, 2012 | Volume: 15 | Issue: 3 | Pages: 400-407

10.1128/aac.15.3.400 Get It

Because excessively high rates of false resistance have been encountered with the 10-μg amikacin disk in diffusion susceptibility tests, a study was performed to examine existing zone diameter interpretative criteria and to compare the accuracy of 10- and 30-μg amikacin disks by the error rate-bounded classification scheme. Although current zone diameter interpretative criteria eliminate false susceptibles, there is an unacceptably high rate of false resistants. This problem can be resolved in most instances by revising the zone diameter interpretative criteria for the 10-μg disk (resistant, ≤9 mm; indeterminate, 10 to 11 mm; susceptible, ≥12 mm) or, preferably, by replacing the 10-μg disk with a 30-μg disk and adopting new interpretative criteria (resistant, ≤14 mm; indeterminate, 15 to 16 mm; susceptible, ≥17 mm). Because of significant differences in performance among media, it is necessary to include Pseudomonas aeruginosa ATCC 27853 among controls routinely tested and to exclude from use lots of Mueller-Hinton agar yielding results outside the 75% tolerance (90% confidence) limits for amikacin.