Back to Authors

Cohoon, Kevin P.

https://orcid.org/0000-0001-8933-7109

Mayo Clinic

Medical College of Wisconsin

Citations 18

Discrepancies in Prevalence of Peripheral Arterial Disease between Lower Extremities at Rest and Postexercise
Cohoon, Kevin P. , Liedl, David , Rooke, Thom W. , Wennberg, Paul W. , Mahe, Guillaume, Liedl, David A, Mahé, Guillaume

International Journal of Angiology | February 16, 2017 | Volume: 26 | Issue: 03 | Pages: 179-185

10.1055/s-0037-1598177 Get It

Background Lower extremity peripheral arterial disease (PAD) is a common medical condition causing substantial morbidity. Limited data exist on whether discrepancies in PAD prevalence exist between the lower extremities using resting ankle-brachial indices (ABIs) and postexercise pressures. Objective We predicted the prevalence of PAD between the lower extremities. Methods and Results Consecutive patients who had undergone a noninvasive arterial lower extremity study at Mayo Clinic, Rochester, MN, between January 1996 and December 2012 with suspected PAD were retrospectively reviewed. We identified 12,312 consecutive patients who underwent an arterial lower extremity and an exercise treadmill study. Prevalence of PAD was assessed at rest and after exercise using two criteria: a resting ABI ≤ 0.90 and a postexercise pressure decrease of > 30 mm Hg. Mean age was 67 ± 12 years and there were 4,780 (39%) women studied. At rest, we found a higher prevalence of PAD on the left extremity (27.4%) compared with the right (24.6%) (p < 0.0001). After exercise, we found a higher prevalence of PAD on the right extremity (25.1%) compared with the left (19.0%) (p < 0.0001). These discrepancies between the prevalence of PAD at rest and after exercise were present in women and men. Conclusion Using validated criteria of a resting ABI of ≤ 0.90 and postexercise ankle pressure decrease > 30 mm Hg, our results suggest that there is a significantly higher prevalence of PAD in the left lower extremity at rest, in contrast to a greater prevalence of abnormal postexercise testing in the right lower extremity. The reason(s) of these discrepancies remain to be studied.
Public reporting: A new threat to high‐risk patients and medical innovation
Cohoon, Kevin P. , Mack, Michael J. , Holmes, David R.

Catheterization and Cardiovascular Interventions | November 16, 2016 | Volume: 89 | Issue: 2 | Pages: 335-337

10.1002/ccd.26841 Get It

Mapping the global geographic potential of Zika virus spread
Samy, Abdallah M , Thomas, Stephanie Margarete , Cohoon, Kevin P. , Peterson, A. Townsend , Wahed, Ahmed Abd El

Memórias do Instituto Oswaldo Cruz | September 17, 2016 | Volume: 111 | Issue: 9 | Pages: 559-560

10.1590/0074-02760160149 Get It

Retrievable inferior vena cava filters can be placed and removed with a high degree of success: Initial experience
Cohoon, Kevin P. , McBride, Joseph J., Friese, J., McPhail, Ian R., Friese, Jeremy L

Catheterization and Cardiovascular Interventions | November 4, 2014 | Volume: 86 | Issue: 4 | Pages: 719-725

10.1002/ccd.25716 Get It

ObjectivesEvaluate the success rate of retrievable inferior vena cava filter (IVC) removal in a tertiary care practice.BackgroundRetrievable IVC filters became readily available in the United States following Food and Drug Administration approval in 2003, and their use has increased dramatically. They represent an attractive option for patients with contraindications to anticoagulation who may only need short‐term protection against pulmonary embolism.MethodsAll patients who had undergone placement of a retrievable IVC filter at Mayo Clinic between 2003 and 2005 were retrospectively reviewed to evaluate our initial experience with retrievable inferior vena cava filters at a large tertiary care center. Results: During a three‐year‐period of time, Mayo Clinic, Rochester, MN placed 892 IVC filters of which 460 were retrievable. Of the 460 retrievable filters placed (249 Günther Tulip®, 207 Recovery®, and 4 OptEase®), retrieval was attempted in 223 (48.5%). Of 223 initial attempts, 196 (87.9%) were initially successful and 27 (12.1%) were unsuccessful. Of the 27 unsuccessful initial retrieval attempts, 23 (85.2%) were because of the presence of significant thrombus within the filter and 4 (14.8%) were because of tilting and strut perforation. Of the 23 filters containing significant thrombus, 9 (39.1%) were later retrieved after a period of anticoagulation and resolution of the thrombus.ConclusionsRetrievable IVC filters can be removed with a high degree of success. Approximately one in ten retrievable IVC filter removal attempts may fail initially, usually because of significant thrombus within the filter. This does not preclude possible removal at a later date. © 2015 Wiley Periodicals, Inc.
Abdominal Aortic Calcium, Coronary Artery Calcium, and Cardiovascular Morbidity and Mortality in the Multi-Ethnic Study of Atherosclerosis
Criqui, Michael H. , Denenberg, Julie O., McClelland, Robyn L. , Allison, Matthew , Guerci, Alan D., Cohoon, Kevin P. , Srikanthan, Preethi , Wong, Nathan D. , Allison, Matthew A, Guerci, Alan, Watson, Karol E., Ix, Joachim H. , Watson, Karol E. , Wong, Nathan , Allison, Matthew A

Arteriosclerosis, Thrombosis, and Vascular Biology | May 9, 2014 | Volume: 34 | Issue: 7 | Pages: 1574-1579

10.1161/atvbaha.114.303268 Get It

Objective— To evaluate the predictive value of abdominal aortic calcium (AAC) for incident cardiovascular disease (CVD) independent of coronary artery calcium (CAC). Approach and Results— We evaluated the association of AAC with CVD in 1974 men and women aged 45 to 84 years randomly selected from the Multi-Ethnic Study of Atherosclerosis participants who had complete AAC and CAC data from computed tomographic scans. AAC and CAC were each divided into following 3 percentile categories: 0 to 50th, 51st to 75th, and 76th to 100th. During a mean of 5.5 years of follow-up, there were 50 hard coronary heart disease events, 83 hard CVD events, 30 fatal CVD events, and 105 total deaths. In multivariable-adjusted Cox models including both AAC and CAC, comparing the fourth quartile with the ≤50th percentile, AAC and CAC were each significantly and independently predictive of hard coronary heart disease and hard CVD, with hazard ratios ranging from 2.4 to 4.4. For CVD mortality, the hazard ratio was highly significant for the fourth quartile of AAC, 5.9 ( P =0.01), whereas the association for the fourth quartile of CAC (hazard ratio, 2.1) was not significant. For total mortality, the fourth quartile hazard ratio for AAC was 2.7 ( P =0.001), and for CAC, it was 1.9, P =0.04. Area under the receiver operating characteristic curve analyses showed improvement for both AAC and CAC separately, although improvement was greater with CAC for hard coronary heart disease and hard CVD, and greater with AAC for CVD mortality and total mortality. Sensitivity analyses defining AAC and CAC as continuous variables mirrored these results. Conclusions— AAC and CAC predicted hard coronary heart disease and hard CVD events independent of one another. Only AAC was independently related to CVD mortality, and AAC showed a stronger association than CAC with total mortality.
Inherited and Secondary Thrombophilia
Cohoon, Kevin P. , Heit, John A.

Circulation | January 13, 2014 | Volume: 129 | Issue: 2 | Pages: 254-257

10.1161/circulationaha.113.001943 Get It

Should Platelet Function Testing Guide Antiplatelet Therapy for Patients with Coronary Artery Stenting or Acute Coronary Syndromes?
Cohoon, Kevin P. , Heit, John A.

Clinical Chemistry | May 25, 2013 | Volume: 59 | Issue: 9 | Pages: 1299-1300

10.1373/clinchem.2012.200881 Get It

The Development of Ascending Aortic Aneurysms After Elective Aortic Valve Replacement With St Jude Mechanical Valve Prosthesis in the Bicuspid Patient
Cohoon, Kevin P. , Foley, Jillian, Dieter, Robert S., Bakhos, Mamdouh, Schwartz, Jeffrey

Angiology | June 21, 2012 | Volume: 64 | Issue: 5 | Pages: 379-384

10.1177/0003319712450504 Get It

The association between bicuspid aortic valve (BAV) and ascending aorta aneurysm is well described. Replacement of the ascending aorta is now being considered at 4.5 cm. We identified patients confirmed with BAV who underwent elective aortic valve replacement (AVR) with a mechanical St Jude Bioprosthesis from 1994 to 2000 who were ≤65 years of age at the time of surgery. Follow-up imaging was obtained by computed tomography (CT) angiography or echocardiography. A total of 225 patients who underwent AVR were identified; 60 patients had a BAV. Of all, 36 (60%) patients with BAV returned for follow-up imaging of their ascending aorta. Eight patients (22%) had diameters classifiable as aneurysmal (>4.5 cm) that developed within 9.6 ± 4.1 years from implant and requiring surgery. Of all, 7 patients (12%) died within 5.9 ± 2.5 years from their implant date. Lifelong serial monitoring of the ascending aorta for patients with BAV should be the standard of care.