Abstract EEG source imaging is becoming widely used for the evaluation of medically refractory focal epilepsy. The validity of EEG source imaging has been established in several studies comparing source imaging to the surgical resection cavity and subsequent seizure freedom. We present a cohort of 87 patients and compare EEG source imaging of both ictal and interictal scalp EEG to the seizure onset zone on intracranial EEG. Concordance of EEG source imaging with intracranial EEG was determined on a sublobar level and was quantified by measuring the distance between the source imaging result and the centroid of the active seizure onset zone electrodes. The EEG source imaging results of a subgroup of 26 patients with high density 76-channel EEG were compared with the localization of three experienced epileptologists. Of 87 patients, 95% had at least one analysis concordant with intracranial EEG and 74% had complete concordance. There was a higher rate of complete concordance in temporal lobe epilepsy compared to extratemporal (89.3 and 62.8%, respectively, P = 0.015). Of the total 282 analyses performed on this cohort, higher concordance was also seen in temporal discharges (95%) compared to extratemporal (77%) (P = 0.0012), but no difference was seen comparing high-density EEG with standard (32-channel) EEG. Subgroup analysis of ictal waveforms showed greater concordance for ictal spiking, compared with rhythmic activity, paroxysmal fast activity, or obscured onset. Median distances from the dipole and maximum distributed source to a centroid of seizure onset zone electrodes were 30.0 and 32.5 mm, respectively, and the median distances from dipole and maximum distributed source to nearest seizure onset zone electrode were 22.8 and 21.7, respectively. There were significantly shorter distances in ictal spiking. There were shorter distances in patients with Engel Class 1 outcome from surgical resection compared to patients with worse outcomes. For the subgroup of 26 high-density EEG patients, EEG source localization had a significantly higher concordance (92% versus 65%), sensitivity (57% versus 35%) and positive predictive value (60% versus 36%) compared with epileptologist localization. Our study demonstrates good concordance between ictal and interictal source imaging and intracranial EEG. Temporal lobe discharges have higher concordance rates than extratemporal discharges. Importantly, this study shows that source imaging has greater agreement with intracranial EEG than visual review alone, supporting its role in surgical planning.
Teaching NeuroImages: Medically intractable epilepsy and ictal asystole treated with cardiac pacing
Our simulation of the release, diffusion, and consumption of oxygen in the capillaries and surrounding tissue of peripheral nerve now includes axial diffusion in blood and in surrounding tissue, in addition to bulk flow of blood and radial diffusion of oxygen out of the capillary. Our simulation assumes that the oxygen consumption of nerve tissue obeys Michaelis-Menten kinetics rather than zero-order kinetics as had been assumed in the Krogh model. We can calculate the oxygen tension at all points in the capillary and surrounding tissue as a function of distance from the center of the nearest capillary and distance along the capillary from the arterial to the venous end. Using average measured values for microcirculatory parameters in rat nerve, we calculated a distribution of oxygen tension values that agrees with experimentally measured distributions. The effects of axial diffusion and of Michaelis-Menten kinetics on the oxygen distributions were noticeable under normal conditions, but these effects were much more important in situations in which oxygen delivery was adversely affected.
Frequent sleep‐related bitemporal focal seizures in transient epileptic amnesia syndrome: Evidence from ictal video‐EEG
SummaryTwo patients who shared similar presenting clinical features of anterograde and retrograde autobiographical amnesia typical of transient epileptic amnesia (TEA) underwent prolonged video electroencephalogram (VEEG) monitoring and were found to have sleep‐activated epileptiform activity and frequent subclinical bitemporal seizures predominantly during sleep. Case 1 is a 59‐year‐old woman whose presenting complaint was memory impairment. Over 18 months, she had three distinct 8‐h‐long episodes of confusion and disorientation with persistent anterograde and retrograde autobiographical amnesia. VEEG recorded frequent interictal bitemporal sharp waves confined to sleep, and 14 subclinical seizures, also mostly during sleep. Case 2 is a 50‐year‐old woman with known focal epilepsy also presented with memory complaints. Over the course of 1 year, she had two discrete 2‐h‐long episodes of amnesia, with ongoing anterograde and retrograde autobiographical amnesia. VEEG recorded independent bitemporal sharp waves, and 14 subclinical seizures during sleep and drowsiness. Memory impairment improved in both patients with successful treatment of their seizures. Although the etiology of accelerated long‐term forgetting (ALF) and remote memory impairment (RMI) in transient epileptic amnesia (TEA) is unknown, these cases suggest frequent sleep‐related seizures may contribute, and they highlight the importance of video‐EEG monitoring.
Routine vs extended outpatient EEG for the detection of interictal epileptiform discharges