Back to Authors

Vahdat, Vahab

Mayo Clinic

Exact Sciences (United States)

Citations 3

Adenoma detection following screening colonoscopy and stool-based colorectal cancer screening tests with follow-up colonoscopy: A systematic and network meta-analysis.
Estes, Chris, Vahdat, Vahab, Johnson, Heather, Thompson, Gina, Brown, J D , Ebner, Derek W., Alagoz, Oguzhan, Anderson, Joseph C., Butterly, Lynn F. , Estes, Chris , Vahdat, Vahab , Johnson, Heather , Thompson, Gina , Kisiel, John B. , Ebner, Derek W. , Alagöz, Oğuzhan , Anderson, Joseph C. , Limburg, Paul J.

Journal of Clinical Oncology | May 28, 2026 | Volume: 44 | Issue: 16_suppl | Pages: No page available

10.1200/jco.2026.44.16_suppl.e15647 Get It

e15647 Background: Colorectal cancer (CRC) screening offers an opportunity to prevent invasive disease by detecting and removing precancerous lesions. Colonoscopy-based detection of adenomas and serrated polyps is strongly associated with reduced risk of interval CRC. While the performance of noninvasive CRC screening tests is well described, comparative evidence on adenoma detection across screening colonoscopy and stool-based strategies with follow-up colonoscopy remains limited. We conducted a systematic review to compare adenoma detection across CRC screening modalities. Methods: MEDLINE (PubMed) and Embase were searched from January 1, 2000, through July 10, 2025, for peer-reviewed, U.S.-based studies reporting colonoscopy among average-risk adults aged ≥45 years, who underwent screening colonoscopy or follow-up colonoscopy after a positive stool-based screening test [fecal immunochemical test (FIT) or multi-target stool DNA (mt-sDNA) test]. The primary outcome was the detection of one or more adenomas at colonoscopy. High-risk or surveillance cohorts, AI-assisted colonoscopy, diagnostic accuracy trials, and non-U.S. studies were excluded. Results: Among 7,710 de-duplicated records, 147 studies underwent full-text review, and 47 studies were included in quantitative synthesis, with reported adenoma detection for screening colonoscopy alone (n = 31), follow-up colonoscopy after a positive FIT alone (n = 4), follow-up colonoscopy after a positive mt-sDNA test alone (n = 4), and for more than one of the screening strategies of interest (n = 8). Across included studies, overall adenoma detection differed by screening pathway. Follow-up colonoscopy after a positive mt-sDNA test demonstrated the highest adenoma detection (66.3%; 95% CI, 61.2-71.1), with lower adenoma detection observed for colonoscopy after a positive FIT (50.6%; 95% CI, 43.4-57.8) and screening colonoscopy alone (33.8%; 95% CI, 30.9-36.8) (Table 1). Conclusions: Detection of adenomas was highest following colonoscopy performed after a positive mt-sDNA test compared with FIT-positive follow-up or screening colonoscopy alone. These findings highlight differences in downstream detection across CRC screening tests and suggest that, in settings where colonoscopy resources are constrained, initial mt-sDNA screening with timely follow-up colonoscopy may help prioritize patients most likely to benefit. CRC screening modality No. of Studies Adenoma detected Study population Proportion, % (95% CI) Heterogeneity, I² (%) Between-study variance (τ 2 ) P-value* mt-sDNA 8 17,436 29,098 66.3 (61.2-71.1) 94.6 0.0924 <0.0001 FIT 11 17,588 32,630 50.6 (43.4-57.8) 94.0 0.2187 <0.0001 Screening colonoscopy 38 2,351,801 6,378,891 33.8 (30.9-36.8) 99.8 0.1710 NA *P-value represents adenoma detection vs. screening colonoscopy adenoma detection.
Model-based evaluation of colorectal cancer screening effectiveness: three rounds of multitarget stool DNA testing versus one colonoscopy
Dore, Michael , Ebner, Derek W., Vahdat, Vahab, Estes, Chris, Ozbay, A. Burak, Foster, Victoria, Limburg, Paul J. , Ebner, Derek W. , Ozbay, A. Burak , Vahdat, Vahab , Doré, Michaël , Ebner, Derek , Vahdat, Vahab , Estes, Chris , Ozbay, A Burak , Limburg, Paul J , Estes, Chris

Journal of Medical Economics | March 25, 2026 | Volume: 29 | Issue: 1 | Pages: 986-993

10.1080/13696998.2026.2645491 Get It

Model-Based Evaluation of Colorectal Cancer Screening Effectiveness: Three Rounds of Multitarget Stool DNA Testing Versus One Colonoscopy
Dore, Michael, Ebner, Derek W., Vahdat, Vahab, Estes, Chris, Ozbay, A. Burak, Foster, Victoria, Limburg, Paul J. , Ebner, Derek W. , Ozbay, A. Burak , Vahdat, Vahab , Doré, Michaël , Dore, Michael , Ozbay, A Burak , Limburg, Paul J , Vahdat, Vahab , Ebner, Derek , Estes, Chris

No container title available | February 2, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.64898/2026.01.30.26344467 Get It

ABSTRACT Background Several colorectal cancer (CRC) screening modalities are guideline-recommended in the United States, yet they vary considerably in screening interval and real-world adherence. As a result, single-round test performance may not reflect cumulative effectiveness over time. This study compared the 10-year longitudinal outcomes of two CRC screening strategies— triennial next-generation multitarget stool DNA testing (ng mt-sDNA) and decennial screening colonoscopy. Methods This study used the validated, microsimulation-based Colorectal Cancer and Adenoma Incidence and Mortality (CRC-AIM) model to estimate 10-year cumulative outcomes for two guideline-recommended screening strategies: triennial ng mt-sDNA and decennial colonoscopy. Model inputs included test-specific performance and real-world adherence. Outcomes included CRC and precancerous lesions detected, CRC mortality reductions, and life-years gained (LYG). Sensitivity analyses examined the effects of varying both screening adherence and follow-up colonoscopy adherence. Results Over 10 years per 1,000 individuals offered screening, the ng mt-sDNA screening test detected 13% more precancerous lesions and 11% more CRC cases than colonoscopy, with a greater proportion of CRCs identified through screening rather than symptomatic detection. ng mt-sDNA resulted in greater CRC mortality reduction (33% vs 20%) and 62% more life-years gained, with consistent findings across sensitivity analyses. Conclusions With real-world adherence, screening with triennial ng mt-sDNA demonstrates superior cumulative effectiveness compared with decennial colonoscopy, driven by higher adherence and favorable longitudinal performance. These findings support the expanded use of noninvasive stool-based screening to reduce CRC mortality and alleviate capacity constraints associated with colonoscopy-based screening. Broader adoption of ng mt-sDNA may enhance population-level CRC prevention by increasing participation and improving early detection across the screening eligible population. Plain language summary Colorectal cancer screening tests are recommended at different time intervals and completed at different adherence rates in clinical practice. The analysis used a validated simulation model to compare 10-year outcomes of triennial next-generation multi-target stool DNA test (ng mt-sDNA) with a single colonoscopy, accounting for real-world screening and follow-up colonoscopy adherence. Our findings indicate that repeated ng mt-sDNA provides greater cumulative screening effectiveness than colonoscopy over a 10-year period.