Abstract Despite the high incidence of COVID-19 worldwide, clinical experience with severe acute respiratory syndrome coronavirus 2 (SARS-COV-2) in inborn errors of immunity remains limited. Recent studies have shown that patients with defects in type 1 interferon (IFN)-related pathways or those with autoantibodies against type 1 IFNs develop severe COVID-19. We reported the clinical course of 22 patients with CTLA-4 insufficiency and COVID-19 and retrospectively examined autoantibodies against type 1 IFNs at baseline. Data were obtained from the patient interviews and chart reviews. Screening for anti-IFN autoantibodies was performed using a multiplex particle-based assay. Student t test, Mann Whitney, analysis of variance, or χ2 tests were used where appropriate. Twenty-two patients aged from 8 months to 54 years, with genetically confirmed CLTA-4 insufficiency, developed COVID-19 from 2020 to 2022. The most common symptoms were fever, cough, and nasal congestion, and the median duration of illness was 7.5 days. Twenty patients (91%) developed mild COVID-19 and were treated as outpatients. Two patients were hospitalized because of COVID-19 pneumonia but did not require mechanical ventilation. Ten (45%) patients were vaccinated at the time of their first COVID-19 infection. Eleven patients received outpatient treatment with monoclonal antibodies against the SARS-CoV-2 spike protein. During the study period, 17 patients were vaccinated against SARS-CoV-2, with no severe vaccine-related adverse effects. Although median anti-S titers following vaccination or infection were lower in patients receiving immunoglobulin replacement therapy (IGRT) (349 IU/dL) than in those not receiving IGRT (2594 IU/dL; P = .15); 3 of 9 patients on IGRT developed titers >2000 IU/dL. All patients tested negative for autoantibodies against IFN-α, IFN-β, and IFN-ω at baseline. Most patients with CTLA-4 insufficiency and COVID-19 had nonsevere disease, lacked autoantibodies against type 1 IFNs, and tolerated messenger RNA vaccines with few adverse effects. Whether our findings can be extrapolated to patients receiving CTLA-4-targeting checkpoint inhibitors requires further studies.
Evaluation of correlation between dose and clinical outcomes in subcutaneous immunoglobulin replacement therapy
Summary The importance of serum immunoglobulin (Ig)G concentration in IgG replacement therapy for primary immunodeficiency diseases is established in certain settings. Generally, IgG is infused via the intravenous (IVIG) or subcutaneous (SCIG) route. For IVIG infusion, published data demonstrate that higher IgG doses and trough levels provide patients with improved protection from infection. The same conclusions are not yet accepted for SCIG; data from two recent Phase III studies and a recent post-hoc analysis, however, suggest the same correlation between higher SCIG dose and serum IgG concentration and decreased incidence of infection seen with IVIG. Other measures of clinical efficacy have not been considered similarly. Thus, combined analyses of these and other published SCIG studies were performed; a full comparison of the 13 studies was, however, limited by non-standardized definitions and reporting. Despite these limitations, our analyses indicate that certain clinical outcomes improve at higher SCIG doses and associated higher serum IgG concentrations, and suggest that there might be opportunity to improve patient outcomes via SCIG dose adjustment.