Back to Authors

Eisenga, John

https://orcid.org/0000-0003-0950-8620

Mayo Clinic

Baylor University Medical Center

Citations 1

Performing Under Pressure: Maintenance of Donor Lung Pressure During Cabin Depressurization
Eisenga, John , Ringenberg, Sigrid, Ahmed, Magdy M. El‐Sayed , Ringenberg, Sigrid, Schwartz, Gary

Interdisciplinary CardioVascular and Thoracic Surgery | January 7, 2026 | Volume: 41 | Issue: 2 | Pages: No page available

10.1093/icvts/ivaf315 Get It

Abstract Introduction: Maintenance of donor lung pressure is recommended to maintain inflation pressures of 12-15 mm Hg. This is particularly important given graft transportation in aircraft, due to the inevitable pressure changes. Case: We describe a case of a donor lung preservation system which maintained proper airway pressure during sudden cabin pressure loss requiring emergent landing. Discussion: The donor lungs were implanted without complication. Post-transplant course was notable for primary graft dysfunction (PGD) grade 1 at 24 hours, grade 2 at 48 hours, and grade 1 at 72 hours. At 3 months post-transplant, the patient has had no respiratory complications and has been noted to be doing well.