Back to Authors

Kramer, Daniel B.

https://orcid.org/0000-0003-4241-3586

Mayo Clinic

Beth Israel Deaconess Medical Center

Citations 19

Potential Unintended Consequences Of Recent Shared Decision Making Policy Initiatives
Opel, Douglas J. , Kramer, Daniel B. , Edmonds, Brownsyne Tucker , Ladin, Keren , Peek, Monica E. , Peppercorn, Jeff, Tilburt, Jon C. , Blumenthal‐Barby, Jennifer , Dickert, Neal W.

Health Affairs | November 4, 2019 | Volume: 38 | Issue: 11 | Pages: 1876-1881

10.1377/hlthaff.2019.00243 Get It

Decision Making Laws for "Unrepresented" Patients
Doyle, Cavan K. , Kramer, Daniel B. , Siegler, Mark, Sulmasy, Daniel P., Mueller, P.S., DeMartino, Erin S. , Sperry, Beau P. , Dudzinski, David M.

B106. CRITICAL CARE: A HUNDRED YEARS OF SOLITUDE - CARING FOR THE VULNERABLE: PATIENT, FAMILY, AND HCP-CENTERED CARE | August 26, 2019 | Volume: No volume available | Issue: No issue available | Pages: A4157-A4157

10.1164/ajrccm-conference.2019.199.1_meetingabstracts.a4157 Get It

Association between the Charlson comorbidity index and outcomes after implantable cardioverter defibrillator generator replacement
Amin, Mustapha M., Witt, Chance M. , Waks, Jonathan W. , Mehta, Ramila A. , Friedman, Paul A. , Kramer, Daniel B. , Buxton, Alfred E. , Mulpuru, Siva K. , Hodge, David O. , Frey, Rebecca J., Frederick, Nicolette K., Cha, Yong‐Mei , Brenes-Salazar, Jorge A., Madhavan, Malini , Brenes-Salazar, Jorge

Pacing and Clinical Electrophysiology | July 29, 2019 | Volume: 42 | Issue: 9 | Pages: 1236-1242

10.1111/pace.13762 Get It

AbstractBackgroundRecipients of implantable cardioverter defibrillator (ICD) generator replacement with multiple medical comorbidities may be at higher risk of adverse outcomes that attenuate the benefit of ICD replacement. The aim of this investigation was to study the association between the Charlson comorbidity index (CCI) and outcomes after ICD generator replacement.MethodsAll patients undergoing first ICD generator replacement at Mayo Clinic, Rochester and Beth Israel Deaconess Medical Center, Boston between 2001 and 2011 were identified. Outcomes included: (a) all‐cause mortality, (b) appropriate ICD therapy, and (c) death prior to appropriate therapy. Multivariable Cox regression analysis was performed to assess association between CCI and outcomes.ResultsWe identified 1421 patients with mean age of 69.6 ± 12.1 years, 81% male and median (range) CCI of 3 (0‐18). During a mean follow‐up of 3.9 ± 3 years, 52% of patients died, 30.6% experienced an appropriate therapy, and 23.6% died without experiencing an appropriate therapy. In multivariable analysis, higher CCI score was associated with increased all‐cause mortality (Hazard ratio, HR 1.10 [1.06‐1.13] per 1 point increase in CCI, P < .001), death without prior appropriate therapy (HR 1.11 [1.07‐1.15], P < .0001), but not associated with appropriate therapy (HR 1.01 [0.97‐1.05], P = .53). Patients with CCI ≥5 had an annual risk of death of 12.2% compared to 8.7% annual rate of appropriate therapy.ConclusionsCCI is predictive of mortality following ICD generator replacement. The benefit of ICD replacement in patients with CCI score ≥5 should be investigated in prospective studies.
US State Regulation of Decisions for Pregnant Women Without Decisional Capacity
DeMartino, Erin S. , Sperry, Beau P. , Doyle, Cavan K. , Chor, Julie , Kramer, Daniel B. , Mueller, Paul S. , Dudzinski, David M.

JAMA | April 23, 2019 | Volume: 321 | Issue: 16 | Pages: 1629

10.1001/jama.2019.2587 Get It

Outcomes After Implantable Cardioverter-Defibrillator Generator Replacement for Primary Prevention of Sudden Cardiac Death
Madhavan, Malini , Waks, Jonathan W. , Friedman, Paul A. , Kramer, Daniel B. , Buxton, Alfred E. , Mehta, Ramila A. , Hodge, David O. , Higgins, Angela , Webster, Tracy L., Witt, Chance M. , Cha, Yong‐Mei , Higgins, Angela Y. , Noseworthy, Peter A. , Gersh, Bernard J.

Circulation: Arrhythmia and Electrophysiology | September 17, 2018 | Volume: 9 | Issue: 3 | Pages: No page available

10.1161/circep.115.003283 Get It

Background— The effectiveness of implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden death in patients with an ejection fraction (EF) ≤35% and clinical heart failure is well established. However, outcomes after replacement of the ICD generator in patients with recovery of EF to >35% and no previous therapies are not well characterized. Methods and Results— Between 2001 and 2011, generator replacement was performed at 2 tertiary medical centers in 253 patients (mean age, 68.3±12.7 years; 82% men) who had previously undergone ICD placement for primary prevention but subsequently never received appropriate ICD therapy. EF had recovered to >35% in 72 of 253 (28%) patients at generator replacement. During median (quartiles) follow-up of 3.3 (1.8–5.3) years after generator replacement, 68 of 253 (27%) experienced appropriate ICD therapy. Patients with EF ≤35% were more likely to experience ICD therapy compared with those with EF >35% (12% versus 5% per year; hazard ratio, 3.57; P =0.001). On multivariable analysis, low EF predicted appropriate ICD therapy after generator replacement (hazard ratio, 1.96 [1.35–2.87] per 10% decrement; P =0.001). Death occurred in 25% of patients 5 years after generator replacement. Mortality was similar in patients with EF ≤35% and >35% (7% versus 5% per year; hazard ratio, 1.10; P =0.68). Atrial fibrillation (3.24 [1.63–6.43]; P <0.001) and higher blood urea nitrogen (1.28 [1.14–1.45] per increase of 10 mg/dL; P <0.001) were associated with mortality. Conclusions— Although approximately one fourth of patients with a primary prevention ICD and no previous therapy have EF >35% at the time of generator replacement, these patients continue to be at significant risk for appropriate ICD therapy (5% per year). These data may inform decisions on ICD replacement.
Risk of Appropriate Therapy and Death Before Therapy After Implantable Cardioverter-Defibrillator Generator Replacement
Witt, Chance M. , Waks, Jonathan W. , Mehta, Ramila A. , Friedman, Paul A. , Kramer, Daniel B. , Buxton, Alfred E. , Mulpuru, Siva K. , Hodge, David O. , Lushinsky, Emilie C., Mulholland, Megan B., Cha, Yong‐Mei , Madhavan, Malini , Noseworthy, Peter A. , Gersh, Bernard J.

Circulation: Arrhythmia and Electrophysiology | September 14, 2018 | Volume: 11 | Issue: 8 | Pages: No page available

10.1161/circep.117.006155 Get It

Background The decision to initially implant an implantable cardioverter-defibrillator (ICD) is informed by robust randomized controlled trials, but no such data exist to guide the decision to replace an ICD generator. In this study, we aimed to determine outcomes after ICD generator replacement. Methods All patients with ischemic or nonischemic cardiomyopathy who underwent ICD generator replacement from 2001 to 2011 at Mayo Clinic, MN, or Beth Israel Deaconess Medical Center, MA, were included. Outcomes included (1) appropriate therapy after generator replacement and (2) death before appropriate therapy after generator replacement. Cox proportional hazards modeling was used to determine the associations between patient characteristics and outcomes. Results In 1421 patients undergoing ICD generator replacement (mean±SD age 69.6±12.1 years, 81% male), appropriate therapy occurred after replacement in 435 patients (30.6%) over a mean follow-up of 2.7±2.6 years. Associated factors included lower left ventricular ejection fraction and history of appropriate therapy before generator replacement. Death before appropriate ICD therapy occurred in 336 (23.7%) patients. Older age, lower left ventricular ejection fraction, and noncardiac comorbidities, including diabetes mellitus, chronic lung disease, peripheral vascular disease, lower hemoglobin, and lower glomerular filtration rate, were associated with greater risk of death before appropriate therapy. A progressive increase in mortality was observed with aggregation of these noncardiac comorbidities. Conclusions The decision to replace the ICD should take into consideration not only left ventricular ejection fraction and history of ventricular arrhythmias, but also comorbid illnesses that may impact the duration and the quality of life.
Cybersecurity and medical devices: A practical guide for cardiac electrophysiologists
Ransford, Benjamin, Kramer, Daniel B. , Kune, Denis Foo, Medeiros, Julio Auto de, Crawford, Thomas , Fu, Kevin , Auto de Medeiros, Julio, Chen, Yan , Xu, Wenyuan

Pacing and Clinical Electrophysiology | May 17, 2017 | Volume: 40 | Issue: 8 | Pages: 913-917

10.1111/pace.13102 Get It

AbstractMedical devices increasingly depend on software. While this expands the ability of devices to perform key therapeutic and diagnostic functions, reliance on software inevitably causes exposure to hazards of security vulnerabilities. This article uses a recent high‐profile case example to outline a proactive approach to security awareness that incorporates a scientific, risk‐based analysis of security concerns that supports ongoing discussions with patients about their medical devices.
Patient Activity and Survival Following Implantable Cardioverter‐Defibrillator Implantation: The ALTITUDE Activity Study
Kramer, Daniel B. , Mitchell, Susan L., Jones, Paul W. , Normand, Sharon‐Lise T. , Hayes, David L. , Reynolds, Matthew R. , Monteiro, João P.

Journal of the American Heart Association | May 16, 2015 | Volume: 4 | Issue: 5 | Pages: No page available

10.1161/jaha.115.001775 Get It

Background Physical activity data are collected automatically by implantable cardioverter‐defibrillators ( ICD s). Though these data potentially provide a quantifiable and easily accessible measure of functional status, its relationship with survival has not been well studied. Methods and Results Patients enrolled in the Boston Scientific LATITUDE remote monitoring system from 2008 to 2012 with ICD s were eligible. Remote monitoring data were used to calculate mean daily activity at baseline (30 to 60 days after implantation), and longitudinally. Cox regression was used to examine the association between survival and increments of 30 minutes/day in both (1) mean baseline activity and (2) time‐varying activity, with both adjusted for demographic and device characteristics. A total of 98 437 patients were followed for a median of 2.2 years (mean age of 67.7±13.1 years; 71.7% male). Mean baseline daily activity was 107.5±66.2 minutes/day. The proportion of patients surviving after 4 years was significantly higher among those in the most versus least active quintile of mean baseline activity (90.5% vs. 50.0%; log‐rank P value, <0.001). Lower mean baseline activity (i.e., incremental difference of 30‐minutes/day) was independently associated with a higher risk of death (adjusted hazard ratio [ AHR ], 1.44; 95% confidence interval [ CI ], 1.427 to 1.462). Time‐varying activity was similarly associated with a higher risk of death ( AHR , 1.48; 95% CI , 1.451 to 1.508), indicating that a patient having 30 minutes per day less activity in a given month has a 48% increased hazard for death when compared to a similar patient in the same month. Conclusions Patient activity measured by ICD s strongly correlates with survival following ICD implantation.
Early Detection of an Underperforming Implantable Cardiovascular Device Using an Automated Safety Surveillance Tool
Mugglin, Andrew S. , Friedman, Paul A. , Kramer, Daniel B. , Kallinen, Linda M., McGriff, Deepa, Hayes, David L. , Hauser, Robert G.

Circulation: Cardiovascular Quality and Outcomes | March 7, 2012 | Volume: 5 | Issue: 2 | Pages: 189-196

10.1161/circoutcomes.111.962621 Get It

Background— Postmarket medical device surveillance in the United States depends largely on voluntary reporting of adverse events. Consequently, early safety signals may be missed, exposing patients to potentially hazardous products. The aim of this study was to assess the feasibility of using an automated safety surveillance tool to detect early signals that a marketed implantable cardiac device was underperforming. Methods and Results— For this purpose, we performed simulated prospective monthly full-cohort and propensity-matched comparative survival analyses on our 3-center database of Sprint Fidelis and Quattro Secure implantable cardioverter-defibrillator leads, using a commercially available automated surveillance tool that was preset to trigger an alert if the log rank probability value was <0.05. During the study, 84 of 1035 Fidelis (8.1%) and 23 of 1675 Quattro (1.4%) leads failed. The simulated full-cohort analysis triggered a sustained alert for Fidelis leads beginning 13 months after the first implant and 2 years before Fidelis leads were removed from the market. Of the 1035 patients who had Fidelis leads, up to 969 (93.6%) were successfully matched to Quattro patients. In the propensity-matched analysis, the alert triggered 22 months after the first Fidelis implant and more than 1 year before the lead was recalled. Conclusions— An active automated safety surveillance system could have identified this implantable cardiovascular device problem substantially sooner than was achieved through existing postmarket surveillance methods. Such a tool, when applied to clinical registries and remote monitoring databases, may limit the exposure of large populations to underperforming and potentially hazardous cardiovascular devices.