Back to Authors

Kowal, Rachel A.

Mayo Clinic

Northern Illinois University

Citations 2

Accuracy of the Garmin Vivoactive 4 for Estimating Heart Rate, Energy Expenditure, and Step Count During Treadmill Exercise
Leon, Matteo F. de, Camic, Clayton L., Kowal, Rachel A., Aldape, Brittney, Lochbaum, Brendan, Stefan, Riley, Chomentowski, Peter J., Jagim, Andrew R. , Male, Brandon M., Jagim, Andrew R , Leon, Matteo F. de , Kowal, Rachel A., Aldape, Brittney, Lochbaum, Brendan, Stefan, Riley R., Male, Brandon

Applied Sciences | January 27, 2026 | Volume: 16 | Issue: 3 | Pages: 1286

10.3390/app16031286 Get It

The purpose of this study was to examine the validity of a Garmin device for estimating heart rate, energy expenditure, and step count during incremental treadmill exercise. Eighteen physically active males (n = 12; mean ± SD age = 22.8 ± 4.7 years; body mass = 83.8 ± 13.4 kg) and females (n = 6; 24.2 ± 5.6 years; 65.2 ± 9.6 kg) completed an incremental treadmill test with the Garmin Vivoactive 4 and criterion methods measuring heart rate, energy expenditure, and step count. Mean absolute percent error (MAPE) and Bland–Altman plots were used to assess accuracy. Acceptable accuracy was defined as MAPE < 5% for heart rate and <10% for energy expenditure and step count. MAPE (±SD) values were 13.0 (±10.1), 19.1 (±15.0), and 4.6 (±5.3)% for heart rate, energy expenditure, and step count, respectively. The Bland–Altman regression analyses illustrated proportional bias was present for heart rate (r = 0.591, p < 0.001) and step count (r = 0.516, p = 0.028), but not energy expenditure (r = 0.351, p = 0.153). These findings indicated that the Garmin Vivoactive 4 provided acceptable accuracy for step count but unacceptable accuracy for heart rate and energy expenditure during incremental treadmill exercise.
Acute Effects of a Multi-Ingredient Preworkout Supplement on Peak Torque and Muscle Excitation During an Isokinetic Fatigue Protocol
Connors, Benjamin R., Camic, Clayton L., Jagim, Andrew R. , Hill, Christopher M. , Chomentowski, Peter J., Kowal, Rachel A., Leon, Matteo F. de , Jagim, Andrew R , Sebastião, Émerson

Sports | November 11, 2025 | Volume: 13 | Issue: 11 | Pages: 404

10.3390/sports13110404 Get It

The primary purpose of this study was to examine the acute effects of a multi-ingredient preworkout supplement (MIPS) on isometric, concentric, and eccentric peak torque and electromyographic (EMG) responses of the leg extensors during a fatiguing isokinetic protocol. Thirteen male subjects (mean age ± SD = 22.9 ± 2.2 years) were assigned in crossover fashion to ingest an MIPS or placebo before an isokinetic protocol that consisted of 30 maximal, concentric and eccentric muscle actions with EMG signals recorded from the vastus lateralis, rectus femoris, and vastus medialis muscles. Immediately before (PRE) and after (POST) the isokinetic fatigue protocol, subjects were assessed for isometric peak torque. The MIPS condition resulted in greater isometric (205 ± 48 vs. 185 ± 44 N·m, p = 0.04) and concentric (121 ± 34 vs. 103 ± 27 N·m, p = 0.015) torque values versus placebo (collapsed across time). For eccentric peak torque as well as EMG amplitude and frequency values, there were no significant (p > 0.05) interactions or main effects for each condition. These findings indicated that acute ingestion of the MIPS enhanced isometric and concentric peak torque of the leg extensors, which was not explained by changes in the EMG signal.