Abstract 4370972: Impact of Aortic Annular Area on Outcomes Following Balloon-Expandable vs. Self-Expandable Valve-in-Valve Transcatheter Aortic Valve Replacement
Background: Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is an increasingly preferred strategy for managing failed surgical bioprosthetic valves, especially in high-risk patients. However, limited data exist comparing outcomes between balloon-expandable (BE) and self-expandable (SE) transcatheter heart valves (THVs) in this setting. The influence of aortic annular area on outcomes by valve type remains poorly understood. This study evaluated the impact of annular area on clinical outcomes following ViV-TAVR with BE vs. SE valves. Methods: We conducted a retrospective, single-center analysis of 353 patients who underwent ViV-TAVR between 2012 and 2024. All had prior surgical bioprosthetic AVR and received either BE (n=267) or SE (n=86) valves. Preprocedural multidetector CT was used to quantify aortic annular area. Transthoracic echocardiography was performed before and after the procedure to assess transvalvular gradients and hemodynamics. The primary endpoint was all-cause mortality. Penalized spline regression was used to model the nonlinear relationship between annular area and mortality and assess interaction by valve type. Results: Median age was 79 (IQR: 72–83) in the BE group and 80 (IQR: 76–85) in the SE group (p=0.07). Female sex was more common in the SE group (32% vs. 22%, p=0.047). Median annular area was 374 mm2 (IQR: 316–440) for BE and 365 mm2 (IQR: 308–432) for SE (p=0.081). Preprocedural gradient and effective orifice area index were 36 mm Hg (IQR: 28–46) and 0.6 cm2/m2 (IQR: 0.5–0.9), respectively, with no significant differences. Median hospital stay was 2 vs. 3 days (p=0.68). Thirty-day mortality was low (1 per group, p=0.36). Median follow-up was 4.0 years (IQR: 1.6–6.4). One- and 5-year survival rates were 94.75% and 61.7%, respectively (p=0.20). Penalized spline analysis showed a nonlinear association between annular area and mortality. The hazard ratio for BE valves declined with increasing annular area and fell below SE valves beyond ~400 mm2. Conclusion: ViV-TAVR is a safe and effective treatment for failed surgical bioprostheses. Smaller annular areas were associated with higher mortality. Outcomes with BE valves improved in larger annuli, suggesting annular area could guide valve selection. Further studies are warranted to validate these observations.
Abstract 4363343: Papillary Muscle Anatomy in Hypertrophic Cardiomyopathy: Comparison to Normal and Impact on Outcomes of Septal Myectomy
Background: Several studies have described anteroapical displacement of the anterolateral papillary muscle (PM) in patients with hypertrophic cardiomyopathy (HCM), implying a role in left ventricular outflow tract obstruction. Some surgeons address PM position during myectomy, but no quantitative imaging measures of abnormal versus normal PM anatomy exist. Objective: To quantify PM anatomy in HCM using cardiac magnetic resonance imaging (CMR) and determine if differences in PM anatomy alter myectomy outcomes. Methods: 143 patients with HCM (median age 58 (IQR 48-65) years, 64% male) who had undergone CMR were compared to 50 healthy controls (median age 32 (IQR 28-50) years, 40% male). The HCM cohort included 50 patients with non-obstructive HCM, 50 with obstructive HCM requiring transaortic myectomy, and 43 with obstructive HCM requiring transapical myectomy. Six independent measurements of PM anatomy were performed (Figure), comprising both established and novel measurements. Intergroup comparisons were made, and correlative analysis of PM measurements was performed using echocardiographic data and surgical outcomes. Results: There was significant variability in PM anatomy in all patients. The SXAd measurement was smaller (26.76 +/- 6.10 mm vs 32.10 +/- 4.85 mm, p < 0.001) in HCM patients versus controls. The 4Cd measurement was smaller in patients with apical HCM than in all other groups (p < 0.001). D_PM, d_apex, and the ratio between these measurements were consistent among all groups. No PM quantification in HCM patients correlated to pre-, intra-, or postoperative LVOT obstruction, NYHA class, or postoperative length of stay. Conclusions: Although there were some statistically significant differences between healthy patients and those with HCM, analysis of six different PM measurements yielded no associations with LVOT obstruction or outcomes of septal myectomy.