Back to Authors

Hopmann, Peter

https://orcid.org/0000-0002-4311-9138

Mayo Clinic

Mayo Clinic

Citations 2

C 11 Choline-PET/CT as a Localization Standard for Reoperative Primary Hyperparathyroidism
Hopmann, Peter , Foster, Trenton R. , Dy, Benzon M. , McKenzie, Travis, Wermers, Robert A. , Lyden, Melanie L. , Lund, Sarah , Foster, Trenton R , Lyden, Melanie, McKenzie, Travis J. , Johnson, Geoffrey B.

The American Surgeon™ | January 6, 2026 | Volume: 92 | Issue: 6 | Pages: 1806-1812

10.1177/00031348251413528 Get It

Introduction Previous studies have demonstrated that C 11 choline positron emission tomography/computed tomography (Choline-PET/CT) can localize abnormal parathyroid glands in the reoperative setting. This study assesses a large volume of patients with primary hyperparathyroidism (1HPT) who underwent Choline-PET/CT to confirm its utility in the setting of negative or equivocal conventional imaging. Methods All patients who underwent Choline-PET/CT for evaluation of 1HPT from July 2017 to July 2024 at a single institution were reviewed. Inclusion criteria were patients who underwent parathyroidectomy and had lab testing to assess for cure (defined as >50% drop from baseline PTH and into normal range, or resolution of hypercalcemia at follow-up). Sensitivity, positive predictive value (PPV), false negative rate (FNR), and accuracy were compared to conventional imaging (neck ultrasound, parathyroid scan, and parathyroid four-dimensional CT (4D-CT)). Subgroup analysis was conducted comparing sensitivity of modalities among index operations and separately in reoperations. Results 84 patients were included for analysis. 61 failed to localize on at least one conventional modality, and 15 failed to localize on all conventional studies. 67 patients (80%) achieved cure, of which 53 were reoperations. Choline-PET/CT outperformed conventional modalities across sensitivity, PPV, FNR, and accuracy. Choline-PET/CT also outperformed conventional modalities when comparing sensitivity in both subgroups. Conclusion C 11 choline-PET/CT is a valuable imaging modality in the reoperative setting and demonstrates utility for index operations. It provides localization when other modalities fail and allows for a high surgical cure rate. Further investigation into its utility as a primary imaging modality is warranted.
MON-755 C11 Choline-PET/CT Is A Localization Standard For Re-operative Parathyroidectomy In Primary Hyperparathyroidism
Hopmann, Peter , Foster, Trenton R. , Dy, Benzon M. , McKenzie, Travis J. , Wermers, Robert A. , Lyden, Melanie L. , Lund, Sarah , Johnson, Geoffrey B.

Journal of the Endocrine Society | October 23, 2025 | Volume: 9 | Issue: Supplement_1 | Pages: No page available

10.1210/jendso/bvaf149.497 Get It

Abstract Disclosure: P. Hopmann: None. S. Lund: None. T. Foster: None. B. Dy: None. T. McKenzie: None. G. Johnson: None. R.A. Wermers: None. M. Lyden: None. Background: Previous studies have demonstrated that C11 choline positron emission tomography/computed tomography (Choline-PET/CT) can localize abnormal parathyroid glands in the re-operative setting. This study assesses a large volume of patients with primary hyperparathyroidism (1HPT) who underwent Choline-PET/CT to confirm its utility in the setting of negative or equivocal conventional imaging. Methods: All patients who underwent Choline-PET/CT for evaluation of 1HPT from July 2017 to July 2024 at a single institution were reviewed. Inclusion criteria were patients who underwent parathyroidectomy and had lab testing to assess for cure (defined as >50% drop from baseline PTH and into normal range, or resolution of hypercalcemia at follow-up). Sensitivity, positive predictive value (PPV), false negative rate (FNR), and accuracy were compared to conventional imaging (neck ultrasound, parathyroid scan, and parathyroid four-dimensional CT (4D-CT)). Subgroup analysis was conducted comparing sensitivity of modalities among index operations, and separately in re-operations. Results: 176 patients were identified. 85 underwent parathyroidectomy, 1 patient was excluded due to lacking data to evaluate for cure. Of 91 patients who did not undergo parathyroidectomy, 45 were non-localizing on all imaging, and 46 had positive Choline-PET/CT findings but opted against surgery due to mild disease or prohibitive re-operative risk. Of the included 84 parathyroidectomy patients, 61 failed to localize on at least one conventional modality, and 15 failed to localize on all conventional studies. 67 patients (80%) achieved cure, of whom 53 were re-operations (range of 1-4 prior operations, average 1.5). Choline-PET/CT outperformed conventional modalities across sensitivity, PPV, FNR, and accuracy. Among index operations, Choline-PET/CT had significantly higher sensitivity than conventional modalities (100% vs 27% for ultrasound, 30% for parathyroid scan, 29% for 4D-CT; p values ≤0.01). This was also true in re-operations (95% for Choline-PET/CT vs 13% for ultrasound, 30% for parathyroid scan, 32% for 4D-CT; p values <0.01). Conclusion: C11 choline-PET/CT is a valuable imaging modality in the re-operative setting and demonstrates utility for index operations. It provides localization when other modalities fail and allows for a high surgical cure rate. Further investigation into its utility as a primary imaging modality is warranted. Presentation: Monday, July 14, 2025