Back to Authors

Greenwood‐Quaintance, Kerryl E.

https://orcid.org/0000-0003-3760-4310

Mayo Clinic

Mayo Clinic

Citations 107

Direct Electrical Current Reduces Bacterial and Yeast Biofilm Formation
Ruiz‐Ruigómez, María , Badiola, Jon , Schmidt-Malan, Suzannah M., Greenwood‐Quaintance, Kerryl E. , Karau, Melissa J. , Brinkman, Cassandra L., Mandrekar, Jayawant N. , Greenwood-Quaintance, Kerryl, Patel, Robin

International Journal of Bacteriology | March 17, 2016 | Volume: 2016 | Issue: No issue available | Pages: 1-6

10.1155/2016/9727810 Get It

New strategies are needed for prevention of biofilm formation. We have previously shown that 24 hr of 2,000 µA of direct current (DC) reducesStaphylococcus epidermidisbiofilm formationin vitro. Herein, we examined the effect of a lower amount of DC exposure onS. epidermidis,Staphylococcus aureus,Escherichia coli,Pseudomonas aeruginosa,Propionibacterium acnes, andCandida albicansbiofilm formation. 12 hr of 500 µA DC decreasedS. epidermidis,S. aureus,E. coli, andP. aeruginosabiofilm formation on Teflon discs by 2, 1, 1, and 2 log10cfu/cm2, respectively (p<0.05). Reductions inS. epidermidis,S. aureus, andE. colibiofilm formation were observed with as few as 12 hr of 200 µA DC (2, 2 and 0.4 log10 cfu/cm2, resp.); a 1 log10 cfu/cm2reduction inP. aeruginosabiofilm formation was observed at 36 hr. 24 hr of 500 µA DC decreasedC. albicansbiofilm formation on Teflon discs by 2 log10 cfu/cm2. No reduction inP. acnesbiofilm formation was observed. 1 and 2 log10 cfu/cm2reductions inE. coliandS. epidermidisbiofilm formation on titanium discs, respectively, were observed with 12 hr of exposure to 500 µA. Electrical current is a potential strategy to reduce biofilm formation on medical biomaterials.
Improved Diagnosis of Prosthetic Joint Infection by Culturing Periprosthetic Tissue Specimens in Blood Culture Bottles
Peel, Trisha , Dylla, Brenda L., Lynch, David T. , Greenwood‐Quaintance, Kerryl E. , Cheng, Allen , Mandrekar, Jayawant N. , Patel, Robin , Peel, Trisha N, Hughes, John G, Hughes, John , Patel, Robin

mBio | January 29, 2016 | Volume: 7 | Issue: 1 | Pages: No page available

10.1128/mbio.01776-15 Get It

ABSTRACT Despite known low sensitivity, culture of periprosthetic tissue specimens on agars and in broths is routine. Culture of periprosthetic tissue samples in blood culture bottles (BCBs) is potentially more convenient, but it has been evaluated in a limited way and has not been widely adopted. The aim of this study was to compare the sensitivity and specificity of inoculation of periprosthetic tissue specimens into blood culture bottles with standard agar and thioglycolate broth culture, applying Bayesian latent class modeling (LCM) in addition to applying the Infectious Diseases Society of America (IDSA) criteria for prosthetic joint infection. This prospective cohort study was conducted over a 9-month period (August 2013 to April 2014) at the Mayo Clinic, Rochester, MN, and included all consecutive patients undergoing revision arthroplasty. Overall, 369 subjects were studied; 117 (32%) met IDSA criteria for prosthetic joint infection, and 82% had late chronic infection. Applying LCM, inoculation of tissues into BCBs was associated with a 47% improvement in sensitivity compared to the sensitivity of conventional agar and broth cultures (92.1 versus 62.6%, respectively); this magnitude of change was similar when IDSA criteria were applied (60.7 versus 44.4%, respectively; P = 0.003). The time to microorganism detection was shorter with BCBs than with standard media ( P < 0.0001), with aerobic and anaerobic BCBs yielding positive results within a median of 21 and 23 h, respectively. Results of our study demonstrate that the semiautomated method of periprosthetic tissue culture in blood culture bottles is more sensitive than and as specific as agar and thioglycolate broth cultures and yields results faster. IMPORTANCE Prosthetic joint infections are a devastating complication of arthroplasty surgery. Despite this, current microbiological techniques to detect and diagnose infections are imperfect. This study examined a new approach to diagnosing infections, through the inoculation of tissue samples from around the prosthetic joint into blood culture bottles. This study demonstrated that, compared to current laboratory practices, this new technique increased the detection of infection. These findings are important for patient care to allow timely and accurate diagnosis of infection.
Antibiofilm Activity of Electrical Current in a Catheter Model
Voegele, Paul, Badiola, Jon , Schmidt-Malan, Suzannah M., Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

Antimicrobial Agents and Chemotherapy | December 29, 2015 | Volume: 60 | Issue: 3 | Pages: 1476-1480

10.1128/aac.01628-15 Get It

ABSTRACT Catheter-associated infections are difficult to treat with available antimicrobial agents because of their biofilm etiology. We examined the effect of low-amperage direct electrical current (DC) exposure on established bacterial and fungal biofilms in a novel experimental in vitro catheter model. Staphylococcus epidermidis , Staphylococcus aureus , Escherichia coli , Pseudomonas aeruginosa , and Candida parapsilosis biofilms were grown on the inside surfaces of polyvinyl chloride (PVC) catheters, after which 0, 100, 200, or 500 μA of DC was delivered via intraluminally placed platinum electrodes. Catheter biofilms and intraluminal fluid were quantitatively cultured after 24 h and 4 days of DC exposure. Time- and dose-dependent biofilm killing was observed with all amperages and durations of DC administration. Twenty-four hours of 500 μA of DC sterilized the intraluminal fluid for all bacterial species studied; no viable bacteria were detected after treatment of S. epidermidis and S. aureus biofilms with 500 μA of DC for 4 days.
Superantigen-Producing Staphylococcus aureus Elicits Systemic Immune Activation in a Murine Wound Colonization Model
Kim, Choon Kwan , Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Tilahun, Ashenafi Y. , Krogman, Ashton , David, Chella S., Pritt, Bobbi S. , Patel, Robin , Rajagopalan, Govindarajan , Kim, Choon K, Patel, Robin , Pritt, Bobbi S

Toxins | December 9, 2015 | Volume: 7 | Issue: 12 | Pages: 5308-5319

10.3390/toxins7124886 Get It

Staphylococcus aureus, the most common cause of wound infection, produces several exotoxins, including superantigens (SAgs). SAgs are the potent activators of the immune system. Given this unique property, we hypothesized that SAgs produced by S. aureus in wounds would have local, as well as systemic immunologic effects. We tested our hypothesis using a novel staphylococcal skin wound infection model in transgenic mice expressing HLA-DR3. Skin wounds were left uninfected or colonized with S. aureus strains producing SAgs or an isogenic strain not producing any SAg. Animals with wounds challenged with SAg-producing S. aureus had increased morbidity and lower serum IL-17 levels compared to those challenged with the SAg non-producing S. aureus (p = 0.027 and p = 0.032, respectively). At Day 8 following microbial challenge, compared to mice with uninfected wounds, the proportion of Vβ8+CD4+ T cells was increased, while the proportion of Vβ8+CD8+ T cells was decreased only in the spleens of mice challenged with SAg-producing S. aureus (p < 0.001). No such changes were measured in mice challenged with SAg non-producing S. aureus. Lungs, livers and kidneys from mice challenged with SAg-producing, but not SAg non-producing, S. aureus showed inflammatory changes. Overall, SAg-mediated systemic immune activation in wounds harboring S. aureus may have clinical implications.
Evaluation of a Genus- and Group-Specific Rapid PCR Assay Panel on Synovial Fluid for Diagnosis of Prosthetic Knee Infection
Melendez, Dante P. , Greenwood‐Quaintance, Kerryl E. , Berbari, Elie F. , Osmon, Douglas R. , Mandrekar, Jayawant N. , Hanssen, Arlen D. , Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | November 5, 2015 | Volume: 54 | Issue: 1 | Pages: 120-126

10.1128/jcm.02302-15 Get It

ABSTRACT We evaluated a genus- and group-specific PCR assay panel using 284 prosthetic knee synovial fluid samples collected from patients presenting to our institution with implant failure. Using the Musculoskeletal Infection Society diagnostic criteria, 88 and 196 samples were classified as showing prosthetic joint infection (PJI) and aseptic failure (AF), respectively. Sensitivities of the synovial fluid PCR panel and culture were 55.6% and 76.1% ( P ≤ 0.001), respectively, and specificities were 91.8% and 97.4% ( P = 0.016), respectively. Among the 70 subjects who had received antibiotics within the month preceding synovial fluid aspiration (48 of whom had PJI), PCR panel and synovial fluid culture sensitivities were 64.5% and 85.4%, respectively ( P < 0.0001). In this group, the PCR panel detected Staphylococcus aureus in two culture-negative PJI cases. Overall, the evaluated molecular diagnostic tool had low sensitivity when applied to synovial fluid.
Evaluation of the FilmArray Blood Culture ID Panel on Biofilms Dislodged from Explanted Arthroplasties for Prosthetic Joint Infection Diagnosis
Vasoo, Shawn , Cunningham, Scott A. , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Hanssen, Arlen D. , Osmon, Douglas R. , Berbari, Elie F. , Patel, Robin , Abdel, Matthew P. , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | May 28, 2015 | Volume: 53 | Issue: 8 | Pages: 2790-2792

10.1128/jcm.01333-15 Get It

Antibiofilm Activity of Low-Amperage Continuous and Intermittent Direct Electrical Current
Schmidt-Malan, Suzannah M., Karau, Melissa J. , Cede, Julia , Greenwood‐Quaintance, Kerryl E. , Brinkman, Cassandra L., Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

Antimicrobial Agents and Chemotherapy | May 27, 2015 | Volume: 59 | Issue: 8 | Pages: 4610-4615

10.1128/aac.00483-15 Get It

ABSTRACT Bacterial biofilms are difficult to treat using available antimicrobial agents, so new antibiofilm strategies are needed. We previously showed that 20, 200, and 2,000 μA of electrical current reduced bacterial biofilms of Staphylococcus aureus , Staphylococcus epidermidis , and Pseudomonas aeruginosa . Here, we tested continuous direct current at lower amperages, intermittent direct current, and combinations of surface materials (Teflon or titanium) and electrode compositions (stainless steel, graphite, titanium, or platinum) against S. aureus , S. epidermidis , and P. aeruginosa biofilms. In addition, we tested 200 or 2,000 μA for 1 and 4 days against biofilms of 33 strains representing 13 species of microorganisms. The logarithmic reduction factor was used to measure treatment effects. Using continuous current delivery, the lowest active amperage was 2 μA for 1, 4, or 7 days against P. aeruginosa and 5 μA for 7 days against S. epidermidis and S. aureus biofilms. Delivery of 200 μA for 4 h a day over 4 days reduced P. aeruginosa , S. aureus , and S. epidermidis biofilms on Teflon or titanium discs. A reduction of P. aeruginosa , S. aureus , and S. epidermidis biofilms was measured for 23 of 24 combinations of surface materials and electrode compositions tested. Four days of direct current delivery reduced biofilms of 25 of 33 strains studied. In conclusion, low-amperage current or 4 h a day of intermittent current delivered using a variety of electrode compositions reduced P. aeruginosa , S. aureus , and S. epidermidis biofilms on a variety of surface materials. The electricidal effect was observed against a majority of bacterial species studied.
Superantigens produced by catheter-associated Staphylococcus aureus elicit systemic inflammatory disease in the absence of bacteremia
Greenwood‐Quaintance, Kerryl E. , Karau, Melissa J. , Tilahun, Ashenafi Y. , Khaleghi, Shahryar, Chowdhary, Vaidehi , David, Chella S., Patel, Robin , Rajagopalan, Govindarajan , Chung, Jin-Won, Tilahun, Ashenafi, Khaleghi, Shahryar Rostamkolaei, Chowdhary, Vaidehi R, Chung, Jin-Won , Patel, Robin

Journal of Leukocyte Biology | May 16, 2015 | Volume: 98 | Issue: 2 | Pages: 271-281

10.1189/jlb.4a1214-577rr Get It

Abstract SAgs, produced by Staphylococcus aureus, play a major role in the pathogenesis of invasive staphylococcal diseases by inducing potent activation of the immune system. However, the role of SAgs, produced by S. aureus, associated with indwelling devices or tissues, are not known. Given the prevalence of device-associated infection with toxigenic S. aureus in clinical settings and the potency of SAgs, we hypothesized that continuous exposure to SAgs produced by catheter-associated S. aureus could have systemic consequences. To investigate these effects, we established a murine in vivo catheter colonization model. One centimeter long intravenous catheters were colonized with a clinical S. aureus isolate producing SAgs or isogenic S. aureus strains, capable or incapable of producing SAg. Catheters were subcutaneously implanted in age-matched HLA-DR3, B6, and AEo mice lacking MHC class II molecules and euthanized 7 d later. There was no evidence of systemic infection. However, in HLA-DR3 transgenic mice, which respond robustly to SSAgs, the SSAg-producing, but not the nonproducing strains, caused a transient increase in serum cytokine levels and a protracted expansion of splenic CD4+ T cells expressing SSAg-reactive TCR Vβ8. Lungs, livers, and kidneys from these mice showed infiltration with CD4+ and CD11b+ cells. These findings were absent in B6 and AEo mice, which are known to respond poorly to SSAgs. Overall, our novel findings suggest that systemic immune activation elicited by SAgs, produced by S. aureus colonizing foreign bodies, could have clinical consequences in humans.
Clinical Characteristics and Outcomes of Prosthetic Joint Infection Caused by Small Colony Variant Staphylococci
Tande, Aaron J. , Osmon, Douglas R. , Greenwood‐Quaintance, Kerryl E. , Mabry, Tad M. , Hanssen, Arlen D. , Patel, Robin , Tande, Aaron , Patel, Robin

mBio | October 1, 2014 | Volume: 5 | Issue: 5 | Pages: No page available

10.1128/mbio.01910-14 Get It

ABSTRACT Small colony variants (SCVs) are naturally occurring subpopulations of bacteria. The clinical characteristics and treatment outcomes of patients with prosthetic joint infection (PJI) caused by staphylococcal SCVs are unknown. This study was a retrospective series of 113 patients with staphylococcal PJI, with prospective testing of archived sonicate fluid samples. SCVs were defined using two-investigator review. Treatment failure was defined as (i) subsequent revision surgery for any reason, (ii) PJI after the index surgery, (iii) prosthesis nonreimplantation due to ongoing infection, or (iv) amputation of the affected limb. There were 38 subjects (34%) with SCVs and 75 (66%) with only normal-phenotype (NP) bacteria. Subjects with SCVs were more likely to have been on chronic antimicrobials prior to surgery ( P = 0.048), have had prior surgery for PJI ( P = 0.03), have had a longer duration of symptoms ( P = 0.0003), and have had a longer time since joint implantation ( P = 0.007), compared to those with only NP bacteria. Over a median follow-up of 30.6 months, 9 subjects (24%) with SCVs and 23 (32%) with only NP bacteria experienced treatment failure ( P = 0.51). Subjects infected with Staphylococcus aureus were more likely to fail than were those infected with Staphylococcus epidermidis (hazard ratio [HR], 4.03; 95% confidence interval [CI], 1.80 to 9.04). While frequently identified in subjects with PJI and associated with several potential predisposing factors, SCVs were not associated with excess treatment failure compared to NP infections in this study, where they were primarily managed with two-stage arthroplasty exchange. IMPORTANCE Bacteria with the small colony variant (SCV) phenotype are described in small case series as causing persistent or relapsing infection, but there are insufficient data to suggest that they should be managed differently than infection with normal-phenotype bacteria. In an effort to investigate the clinical importance of this phenotype, we determined whether SCVs were present in biofilms dislodged from the surfaces of arthroplasties of patients with staphylococcal prosthetic joint infection and assessed the clinical outcomes associated with detection of SCVs. We found that prosthetic joint infection caused by SCV staphylococci was associated with a longer duration of symptoms and more prior treatment for infection but not with an increased rate of treatment failure, compared to infection caused by normal-phenotype staphylococci.
Prevention of Staphylococcus Epidermidis Biofilm Formation Using Electrical Current
Pozo, José Luís del , Rouse, Mark S., Euba, Gorane , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Steckelberg, James M., Patel, Robin , Del Pozo, Jose L, Patel, Robin

Journal of Applied Biomaterials & Functional Materials | September 5, 2014 | Volume: 12 | Issue: 2 | Pages: 81-83

10.5301/jabfm.5000208 Get It

A technique for the prevention of staphylococcal adhesion by electrical current exposure was investigated. Teflon coupons were exposed to a continuous flow of 10 3 cfu/ml Staphylococcus epidermidis with or without 2000 microA DC electrical current delivered by electrodes on opposite sides of a coupon, touching neither each other nor the coupon. A mean 3.46 (SD, 0.20) and 5.70 (SD, 1.03) log 10 cfu/cm 2 were adhered to the non-electrical current exposed coupons after 4 h and 24 h, respectively. A mean 2.46 (SD, 0.31) and 1.47 (SD, 0.73) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by graphite electrodes. A mean 2.21 (SD, 0.14) and 0.55 (SD, 0.00) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by stainless steel electrodes. Electrical current may be useful in the prevention of staphylococcal adhesion to biomaterials.