ABSTRACT Pulmonary vein thrombosis (PVT) is an uncommon but potentially fatal condition that is often underdiagnosed due to nonspecific clinical presentation. We report a case of a 47‐year‐old woman with a thrombus in the right inferior pulmonary vein incidentally found during a robotic‐assisted bronchoscopy biopsy (RAB) and endobronchial ultrasound (EBUS) performed for mediastinal evaluation and lymph node sampling. PVT was confirmed with computed tomography pulmonary angiography, and the patient was successfully treated with anticoagulation therapy. A review of the literature revealed that reports of PVT detected via EBUS are exceedingly rare and usually malignant in nature. To our knowledge, this is the first peer‐reviewed case report describing PVT identified incidentally during EBUS, underscoring the potential of this technique to reveal clinically significant vascular abnormalities.
C79-06 Robotic Assisted Bronchoscopy With Endobronchial Pulsed Electric Field Ablation Behind an Obstructed Airway
Abstract Introduction Pulsed Electric Field (PEF) Ablation has been used as an adjunct therapy for cancer. Robotic-Assisted Bronchoscopy (RAB) enables precise access to pulmonary lesions for biopsy and ablative therapy. However, anatomic obstructions within the airway may prohibit access to peripheral targets. We report a case in which robotic bronchoscopy navigation for the delivery of PEF was not initially possible due to a new anatomic airway obstruction secondary to radiation fibrosis. We were able to utilize therapeutic bronchoscopy to re-cannulate the airway and deliver the PEF via the robotic bronchoscope. Case Report A 68-year-old man with a history of left lung adenocarcinoma was treated with surgery, chemoradiation and durvalumab consolidation therapy. Surveillance imaging 4 years later revealed consolidation in the right upper mediastinum. A bronchoscopy brush biopsy confirmed adenocarcinoma and received systemic chemotherapy. Later a PET-CT showed a non FDG avid enlarged right paratracheal lesion. Follow-up CT revealed complete obstruction of the right middle lobar bronchus with associated middle lobe collapse likely secondary to radiation. Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) of the right paratracheal lesion confirmed malignancy on onsite cytopathology. Subsequently, we performed two PEF ablations targeting the involved lesion. Repeat PET-CT demonstrated two hypermetabolic foci in the right hilum and right supraclavicular region. However, the previously PEF treated paratracheal lesion was not PET avid. We used a RAB to navigate into the right upper lobe and identified the anterior segment to be obstructed in addition to the previously noted right middle lobe. Due to this, the robotic bronchoscope couldn’t be advanced to the right hilar PET avid lesion. Utilizing guidewires, balloon dilatation and fluoroscopy we re-cannulated the obstructed right upper lobe segment and subsequently advance the robotic bronchoscope to the target in the right upper lobe. Under cone-beam guidance, multiple biopsies were obtained and confirmed as malignant. Following this, the INUMI PEF needle was deployed. We delivered two PEF activations to the right hilar PET-avid lesion. Subsequent systemic staging using linear EBUS identified station 4R lymph node involvement, positive for malignancy on rapid onsite cytopathologic evaluation. The 4R lymph node was superior to the previously treated paratracheal lesion. We then deployed the INUMI PEF needle, and PEF ablation was performed successfully. Discussion To our knowledge, this is the first reported instance of combining robotic and therapeutic bronchoscopy to overcome airway obstruction to facilitate the distal treatment of peripheral target with PEF. This abstract is funded by: None
C44-26 Robotic-assisted Bronchoscopy for Fungal Lung Infections: Overcoming the Diagnostic Limitations of Bronchoalveolar Lavage (BAL) Antigen Testing
Abstract Introduction The diagnosis of fungal lung infections remains challenging as standard tests, such as bronchoalveolar lavage (BAL) antigen testing, often yield variable or inconclusive results. These limitations can delay appropriate therapy and may require additional tissue sampling for definitive diagnosis. Robotic-assisted bronchoscopy (RAB) biopsy has been primarily used as a minimally invasive technique for assessing suspicious peripheral pulmonary lesions (PPL). This case series highlights the diagnostic utility of RAB for identifying fungal infections within PPL when conventional BAL antigen analysis is non-diagnostic. Case Description Four patients with suspected infectious or malignant PPL underwent RAB-guided biopsy for diagnostic clarification, all yielding histopathologic confirmation of fungal disease. The first, a 73-year-old bilateral lung-transplant recipient with hemoptysis, had a negative BAL Aspergillus antigen despite RAB biopsy confirming Aspergillus infection. Similarly, a second 73-year-old man with chronic obstructive pulmonary disease (COPD) and esophageal adenocarcinoma had a negative BAL antigen, while RAB biopsy of bilateral cavitary lesions confirmed Aspergillus. Additionally, a 39-year-old woman with a nodule being evaluated for malignancy, had negative BAL Histoplasma antigen and PCR, whereas RAB biopsy confirmed Histoplasma capsulatum. In contrast, a 56-year-old woman with a right-lower-lobe nodule had a positive BAL Aspergillus antigen that aligned with the histopathologic biopsy findings. Discussion BAL-based antigen testing demonstrates variable diagnostic accuracy in fungal lung disease. Reported sensitivities for Aspergillus detection are typically high in meta-analysis, approximately 80%-90%, but clinical performance in the immunocompromised or high-risk patients is often substantially lower. Similarly, while BAL antigen testing for Histoplasma performs well in disseminated infections, it often fails to detect localized pulmonary disease. In this series, three out of four patients had negative BAL results in the presence of histopathologic confirmation of fungal infection. While current guidelines consider BAL positivity supportive of a “probable” diagnosis, tissue histopathology remains the gold standard for a “proven” infection. These findings emphasize the value and capability of RAB in obtaining direct tissue confirmation when conventional testing, such as BAL antigen analysis, is non-diagnostic. Conclusion RAB-guided biopsy of PPLs offers the opportunity for histopathologic confirmation of fungal infection when BAL testing is non-diagnostic. This approach can enhance upfront diagnostic yield in patients with suspected fungal pulmonary infections, avoiding delays in diagnosis and treatment initiation. This abstract is funded by: None
AIM (Anticipate/Adjust, Image, Manage) to Prevent Bleeding During Robotically‐Assisted Bronchoscopic Ablation
ABSTRACTTherapeutic treatment of lung nodules by ablation is a new field. Even though not considered standard of care, lung nodule ablation can be appropriate for select cases. Even though ablation is a safe and well‐tolerated procedure, bleeding is a potential complication. We introduce our stepwise approach through two cases on how we AIM (Anticipate/Adjust, Image, Manage) to prevent uncontrolled bleeding during Robotically Assisted Bronchoscopic Ablation: 1. Anticipate structures with high risk for bleeding and adjust accordingly, accounting for the needle ablation field; 2. Image: utilise cone beam CT before the first and after each ablation session to screen for bleeding; 3. Manage bleeding by pre‐emptively utilising Fogarty balloon occlusion.