Back to Authors

Pajaro, Octavio E.

Mayo Clinic

Mayo Clinic in Arizona

Citations 4

SynCardia Portable Freedom Driver: A Single-Center Experience with 11 Patients
Jaroszewski, Dawn E. , Schroedl, L., Staley, Linda L., Pajaro, Octavio E., Kasirajan, Vigneshwar , Arabía, Francisco A. , Shah, Nilay R., Ashfaq, Awais

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | January 3, 2019 | Volume: 10 | Issue: 3 | Pages: 188-194

10.1177/155698451501000308 Get It

SynCardia Portable Freedom Driver: A Single-Center Experience with 11 Patients
Jaroszewski, Dawn E. , Schroedl, L., Staley, Linda L., Pajaro, Octavio E., Kasirajan, Vigneshwar , Arabía, Francisco A. , Shah, Nilay R, Shah, Nilay R. , Ashfaq, Awais

Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery | July 16, 2015 | Volume: 10 | Issue: 3 | Pages: 188-194

10.1097/imi.0000000000000161 Get It

Objective The portable Freedom Drive (SynCardia Inc, Tucson, AZ USA) for total artificial heart (TAH-t) support was approved for an investigational device exemption study in March 2010. We review our center's experience with the portable driver. Methods A retrospective review was conducted of patients who underwent TAH-t implantation and transfer to portable driver from September 2008 to June 2012, with follow-up through December 2012. Results A total of 30 patients underwent TAH-t implantation during this time period, with 11 patients successfully transferred to the Freedom Driver. Transfer to Freedom Driver after TAH-t implant was a median of 46 days (range, 225–86 days). Ninety-one percent (10) of 11 patients transferred to Freedom Driver were bridged to transplantation. One patient died on support. Five (45.5%) of 11 patients were discharged home and 5 (45.5%) remained in-patient on the portable driver before transplantation. Four patients (80%) successfully discharged home required at least 1 hospital readmission (range, 1–5 admissions per patient). Six patients (55%) transferred to the portable driver required a return to a main driver console. Two patients were temporarily maintained on the main driver then returned to the Freedom Driver for bridge to transplantation. Conclusions Patients with TAH-t can be considered for transfer to the portable Freedom Driver while awaiting transplantation. Issues that complicated this patient population included inadequate social support, hemodynamic instability, and concurrent morbidities. The potential benefits of the portable driver are currently undergoing assessment. These may include increased mobility and improved quality of life, opportunity for discharge home, and decreased overall medical costs.
Role of total artificial heart in the management of heart transplant rejection and retransplantation: case report and review
Kalya, Anantharam , Jaroszewski, Dawn E. , Pajaro, Octavio E., Scott, Robert L. , Gopalan, Radha , Kasper, Diane, Arabía, Francisco A.

Clinical Transplantation | May 31, 2013 | Volume: 27 | Issue: 4 | Pages: No page available

10.1111/ctr.12146 Get It

AbstractCardiac allograft rejection and failure may require mechanical circulatory support as bridge‐to‐retransplantation. Prognosis in this patient group is poor and implantable ventricular assist devices have had limited success due to organ failure associated with the high dose immunosuppression required to treat ongoing rejection. We present a case from our institution and the world‐wide experience utilizing the SynCardia CardioWest Total Artificial Heart (TAH‐t; SynCardia Systems, Inc., Tucson, AZ, USA) for replacement of the failing graft, recovery of patient and end‐organ failure with ultimate bridge to retransplantation. We present our experience and review of world‐wide experience for use of TAH‐t in this type patient.
Antibody-Mediated Rejection in Heart Transplantation: Case Presentation with a Review of Current International Guidelines
Pajaro, Octavio E., Jaroszewski, Dawn E. , Scott, Robert L. , Kalya, Anantharam , Tazelaar, Henry D. , Arabía, Francisco A. , Tazelaar, Henry D.

Journal of Transplantation | December 7, 2011 | Volume: 2011 | Issue: No issue available | Pages: 1-7

10.1155/2011/351950 Get It

Antibody-mediated rejection (AMR) (humoral rejection) of cardiac allografts remains difficult to diagnose and treat. Interest in AMR of cardiac allografts has increased over the last decade as it has become apparent that untreated humoral rejection threatens graft and patient survival. An international and multidisciplinary consensus group has formulated guidelines for the diagnosis and treatment of AMR and established that identification of circulating or donor-specific antibodies is not required and that asymptomatic AMR, that is, biopsy-proven AMR without cardiac dysfunction is a real entity with worsened prognosis. Strict criteria for the diagnosis of cardiac AMR have not been firmly established, although the diagnosis relies heavily on tissue pathological findings. Therapy remains largely empirical. We review an unfortunate experience with one of our patients and summarize recommended criteria for the diagnosis of AMR and potential treatment schemes with a focus on current limitations and the need for future research and innovation.