Radiographs were studied of 91 feet in 62 patients with the diagnosis of bunionette and no prior bunionette or hallux valgus operations. Various radiologic measurements were compared to a matched control group with no bunionette symptoms or previous forefoot operations. The bunionette group had a significantly increased metatarsophalangeal 5 angle, intermetatarsal 4–5 angle, and intermetatarsal 1–2 angle compared to the control group. Bunionettes were not commonly associated with lateral bowing of the fifth metatarsal or with an increased fifth metatarsal head width. Symmetry was noted between symptomatic and opposite asymptomatic feet, with the exception of an increased intermetatarsal 4–5 angle in the symptomatic feet.
Ankle Stability in Simulated Lateral Ankle Ligament Injuries
Background: We performed a laboratory-based study of the ankle-hindfoot complex in normal cadaveric ankles with simulated lateral ankle ligament injuries, utilizing an ankle stability testing device. The ankle stability testing device distinguished between intact, injury to anterior talofibular ligament (ATFL) and combined injury to ATFL and calcaneofibular ligament (CFL). Materials and Methods: Ankles were tested in an ankle stability testing device, with a specified inversion torque applied through the range of sagittal plane motion, then internal rotation torque applied through the entire range of sagittal plane motion. Three-dimensional motion of the calcaneus and talus in relation to the tibia were determined with a magnetic tracking system. The specimens were tested in the intact condition, then after sectioning the ATFL, then the CFL. Results: Upon sectioning the ATFL, there was a significant increase in the internal rotation motion at the tibiotalar joint. Subsequent sectioning of the CFL did not significantly increase ankle-hindfoot internal rotation, but it did significantly increase the motion in inversion testing. This increase occurred primarily at the tibiotalar level. Conclusion: The isolated ATFL injury was clearly distinguished from the intact condition by increased talar-tibial internal rotation, but not inversion. The more severe combined ATFL/CFL injury was distinguished from the ATFL injury condition with inversion torque. Clinical Relevance: Inversion torque may disclose combined ATFL/CFL injury, and internal rotation torque may be the key to distinguish isolated ATFL and combined ATFL/CFL injuries.
Advances in biomechanics of posterior tibial tendon dysfunction and flatfoot deformity
We defined foot and ankle motion with respect to the neutral position. Thirteen normal fresh-frozen speci mens of the human foot were used. The foot was placed in the extreme positions of pronation, supina tion, dorsiflexion, and plantar flexion, and positions of multiple bones were monitored simultaneously with a magnetic tracking device to determine rotation of the talocrural, subtalar, metatarsal-navicular, and talo navicular joints under the various conditions. In prona tion, the most rotation occurred at the metatarsal-na vicular level, followed by the navicular-talar, talar-tibial, and calcaneal-talar levels. In supination, most rotation occurred at the navicular-talar level, followed by the calcaneal-talar, talar-tibial, and metatarsal-navicular levels. In dorsiflexion, most rotation occurred at the talar-tibial level, followed by the navicular-talar, calca neal-talar, and metatarsal-navicular levels. In plantar flexion, most rotation occurred at the talar-tibial level, but there was considerable motion at the navicular- talar, metatarsal-navicular, and calcaneal-talar levels. Understanding the specific joint motions that occur with various positions of the foot and ankle is important because measurements of joint mobility may assist in establishing diagnoses, monitoring clinical conditions, determining indications for operative treatment, as sessing results of treatment, and following the progress of rehabilitation.
IN VITRO SIMULATION OF THE STANCE PHASE IN HUMAN GAIT
The purpose of this study is to develop an electromechanical system for dynamic simulation of the stance phase of a human gait using cadaveric foot specimens. The system can be used for quantification of foot and ankle pathomechanics and design of foot and ankle reconstructive surgeries. Servo-pneumatic systems were used for application of the tibial weight loading and muscle loadings. A four-bar mechanism was constructed to provide the progressive motion of a tibia during the simulation while the external loadings were simultaneously applied. Muscle loadings were estimated based on the physiological cross-sectional area and normal electromyography (EMG) data with the assumption of the linear EMG–force relationship. Ad hoc tuning of the unknown muscle gains was conducted until a reasonable match with the normal vertical ground reaction force profile, center of pressure advancement, and characteristic foot motion events (heel strike, foot flat, heel rise and toe-off) could be made. Three cadaver feet and an artificial foot were tested with five repeated trials. The simulator reproduced the stance phase of a human gait in the sagittal plane with reasonable accuracy and consistency without compromising either kinematics or kinetics of the foot and ankle complex.