Back to Authors

Pereda, Daniel

https://orcid.org/0000-0002-0526-8722

Mayo Clinic

Universitat de Barcelona

Citations 1

Longitudinal outcomes following international multicentre experience with robotic aortic valve replacement
Wei, Lawrence M. , Pereda, Daniel , Khaliel, Feras , Murtaza, Ghulam , Mehaffey, J Hunter, Poffo, Robinson , Černý, Štěpán , Melnitchouk, Serguei , Smith, Robert L. , Raikar, Goya V., Darehzereshki, Ali , Geirsson, Arnar , Navia, José , Bonatti, Johannes , Badhwar, Vinay , Arghami, Arman , Badhwar, Vinay , Ramzy, Danny , Mehaffey, James Hunter , Chi, Nai‐Hsin , Vojáček, Jan , Weber, Alberto C. , Arghami, Arman

European Journal of Cardio-Thoracic Surgery | March 29, 2025 | Volume: 67 | Issue: 4 | Pages: No page available

10.1093/ejcts/ezaf103 Get It

Abstract Objectives In an effort to maintain the technical aspects of traditional prosthetic surgical aortic valve replacement (AVR) while reducing invasiveness and facilitate options for concomitant operations, transaxillary lateral mini-thoracotomy endoscopic robotic-assisted aortic valve replacement (RAVR) has been introduced. The present data highlight the contemporary international collaborative experience. METHODS All consecutive patients undergoing standardized RAVR across 10 international sites (1/2020–7/2024) were evaluated using a central database with 1 year follow-up. RESULTS A total of 300 patients were analysed with a median predicted risk of 1.6% with aortic stenosis in 85.7%, nearly half with bicuspid valves. Biological prostheses were implanted in 220 (73.3%) with a median valve size 23 mm, 10% receiving aortic root enlargement, with 17% of all patients undergoing concomitant procedures. Median cross-clamp 120 min with no conversions to sternotomy. Median length of stay was 5 days, 4.3% with prolonged ventilation, 1.7% renal failure, 1.0% stroke and 8.3% required re-thoracotomy for evacuation of haemothorax. There were two 30-day operative mortalities (0.7%). The new permanent pacemaker rate for the full cohort was 2.6%. Of 163 patients with complete 1-year clinical and echocardiographic follow-up, mean aortic valve gradient was 10 mmHg and all but 2 patients (1.2%) had trace to no prosthetic or paravalvular insufficiency. CONCLUSIONS RAVR is safe and effective, providing the reproducible benefits of surgical AVR while affording a less invasive approach that permits the opportunity for concomitant procedures. For low and intermediate risk patients with aortic valve disease, RAVR is a potential reproducible alternative for patients and heart teams.