Abstract Introduction Periacetabular osteotomy (PAO) is performed in the setting of hip dysplasia to increase acetabular coverage of the femoral head and improve joint biomechanics and longevity. PAO fixation is generally achieved with two or three 4.5 mm screws, as compared to the generally more substantial plate and screw constructs used in the setting of acetabular fractures or pelvic ring injuries. The purpose of this study was to evaluate postoperative changes in hip joint center medialization and lateral acetabular coverage following PAO, understanding that these radiographic measures are generally used to guide intra-operative assessment of correction. Methods A retrospective chart review of 100 consecutive PAOs during 2021-2023 at a single academic institution by four surgeons was performed. Perioperative radiographs and fluoroscopy images were evaluated to measure lateral center edge angle (LCEA), Tönnis angle, and medialization of the hip joint center. The hip joint center was measured at one-third of the diameter of the femoral head from inferior to superior, to the ilioischial line, as previously validated by Fowler and colleagues. Results One hundred PAOs in 87 patients (87% female, mean age: 23.0 years) were included. Average preoperative radiographic parameters were 19.9° for LCEA, 12.5° for Tönnis angle, and 12.6 mm for distance from the femoral head to ilioischial line. Ninety-four cases (94%) used three screws, and 6 cases (6%) used two screws for unstable fragment fixation. On immediate postoperative films, average correction was to 28.3° for LCEA, 4.9° for Tönnis angle, and 1.9 mm of pre- to postoperative femoral head medialization (p≤0.001). Patients were radiographically followed for an average of 13.3 months, with an average time to radiographic union of 7.1 months. During the course of follow-up, LCEA increased to 29.3°, Tönnis angle remained to 5.0° (p=0.47), and medialization increased to 2.7 mm (p≤0.02), suggesting further significant but clinically modest increases in lateral coverage and femoral head medialization. Conclusion While the majority of lateral acetabular coverage and femoral head medialization occurs intra-operatively at the time of PAO, patients undergo modest but statistically significant postoperative increases in lateral coverage and medialization prior to radiographic union.
Dry Arthroscopic Hip Labral Repair to Minimize Use of Irrigation Fluid
Abstract Hip arthroscopy is a technically demanding procedure that can require a substantial volume of irrigation fluid. Techniques should be explored to optimize fluid use while ensuring satisfactory surgical instrumentation and labral repair. In this technical note, we present a method for performing a dry arthroscopic labral repair. This technique can be used in the treatment of a variety of labral pathologies, including primary labral repair with knotless or hand‐tied anchors, revision labral repair, and labral reconstruction, without the need for irrigation fluid. Additionally, we discuss supplemental techniques that can be used during other portions of the arthroscopic hip procedure to limit irrigation fluid use. Technique Video video See video under supplementary data.