Heart failure with reduced ejection fraction is a major cause of morbidity and mortality. Cardiac resynchronization therapy (CRT) improves outcomes but faces challenges such as unsuccessful lead placement and suboptimal responses. The Wireless Stimulation Endocardially for CRT (WiSE-CRT) system, a novel leadless left ventricular (LV) pacing technology, uses ultrasonic energy to deliver electrical stimulation directly to the LV endocardium, potentially improving the response rates. A comprehensive literature search was performed across multiple databases from inception until August 2024. The outcomes of interest included the New York Heart Association (NYHA) functional score, LV ejection fraction (LVEF), LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), and QRS duration. Statistical analysis involved pooling the mean differences (MDs) and their corresponding 95% confidence intervals (CIs) from each study using the inverse-variance random-effects model in RevMan version 5.4.1 software. Seven studies, including 468 patients with heart failure treated with the WiSE-CRT system, were included. The pooled analysis showed significant improvements in NYHA functional score (MD: −0.44; 95% CI: −0.67 to −0.21; P = 0.0002; I 2 = 77%), LVEF (MD: 5.71; 95% CI: 4.54 to 6.87; P < 0.001), LVEDV (MD: −24.49; 95% CI: −33.24 to −15.73; P < 0.001), and LVESV (MD: −24.47; 95% CI: −32.80 to −16.14; P < 0.001). The QRS duration also decreased significantly (MD: −38.62; 95% CI: −46.76 to −30.49; P < 0.001; I 2 = 60%). The WiSE-CRT system significantly improved NYHA functional score, LVEF, QRS duration, LVEDV, and LVESV in patients with heart failure. This leadless pacing technology offers a promising alternative for ineligible candidates or for those who do not respond to conventional CRT.
Detection of Myocardial Deformation Patterns and Prognostic Value of Routine Echocardiographic Parameters in Patients with Cardiac Sarcoidosis Versus Extracardiac Sarcoidosis: Systematic Review and Meta-Analysis
Background: Sarcoidosis is a multisystem disorder characterized by non-caseating granulomas in various organs. While cardiac sarcoidosis (CS) is clinically rare, it has significant implications, including heart failure, ventricular arrhythmias, and sudden cardiac death. Speckle-tracking echocardiography has emerged as a promising tool for detecting subclinical myocardial dysfunction, which is cost-efficient and readily available. This meta-analysis aims to evaluate differences in functional echocardiographic parameters between patients with CS and extracardiac sarcoidosis (ECS) to improve early recognition and management. Methods: A comprehensive search of major bibliographic databases was conducted to identify studies up to December 2024. Mean differences (MDs) with 95% CIs were pooled using the inverse-variance random-effect model. Results: Seven studies with 478 patients with sarcoidosis (CS: 159 and ECS: 319) were included. Patients with CS had a significant reduction in left ventricular global longitudinal strain (MD: −2.73; 95% CI: −4.09, −1.38; p < 0.0001) and tricuspid annular plane systolic excursion (MD: −0.59; 95% CI: −1.12, −0.05; p = 0.03) compared to patients with ECS. No significant differences in the LV global circumferential strain, interventricular septum thickness, left ventricular ejection fraction, E/A ratio, E/E’ ratio, LV end-diastolic diameter, and LV end-systolic diameter were noted. Conclusions: LV GLS and TAPSE are promising parameters for the early detection of cardiac involvement in sarcoidosis, with significant prognostic implications. Although STE provides a cost-effective and accessible alternative to CMR and FDG-PET, further research is needed to standardize its use and validate diagnostic cut-offs.