Back to Authors

Segond, Nicolas

https://orcid.org/0000-0002-1049-9816

Mayo Clinic

Centre Hospitalier Universitaire de Grenoble

Citations 2

Abstract Sun106: Effects of different positive pressure ventilation delivery methods on intraventricular, central and peripheral hemodynamics during automated head-up CPR
Poorzand, Pouria, Salverda, Bayert, Moore, Johanna , Metzger, Anja, Suresh, Mithun , Segond, Nicolas , Bachista, Kerry, Lurie, Keith G. , Poorzand, Pouria

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.sun106 Get It

Background: The efficacy of different conventional ventilation during automated head-up (AHUP) CPR using active decompression and impedance threshold device with head and torso elevation is unknown. We sought to determine the central and peripheral hemodynamics while using the 10:1 versus the 30:2 positive pressure ventilation (PPV). Research Question: Does the PPV delivery method affect the hemodynamics during AHUP-CPR? Methods: Ventricular fibrillation was induced in anesthetized pigs (n=5), followed by AHUP-CPR initiation with positive pressure ventilations applied using an automated bag compressor to deliver 10ml/kg of tidal volume over 1 sec at a rate of 10 breaths/min. After 15 minutes of CPR using a 10:1 ratio, ventilation was changed to a 30:2 ratio for 2 minutes with 2 PPV delivered consecutively. Thereafter 10:1 ratio was resumed followed by another 2-minute round of 30:2 PPV mode. Intraventricular pressures and volumes using conductance catheters placed in the right ventricle (RV), along with other hemodynamic parameters were recorded continuously, during the 2-minute intervals between PPV delivery. A mixed-effects model was used to evaluate the effects of PPV mode on pressure-volume (PV) loop parameters while using a Spearman correlation to explore the relationship between PV loop indices. Results: There was no statistically significant difference between RV stroke volume (SV) with 10:1 versus 30:2 PPV mode (Table 1). Throughout 2 minutes, 30:2 ventilation mode resulted in a significantly higher end-tidal CO2 (ETCO2), and higher pressures with a higher pulmonary elastance (Ea) imposed on RV (p<0.05). Higher Ea was strongly correlated with lower SV and ETCO2 (Spearman's rho correlation confidence of -0.97 and -0.83, respectively). No significant differences were observed between the two ventilation modes in any other hemodynamic parameters, including intrathoracic, aortic and right atrial pressures, as well as coronary and cerebral perfusion pressures. Conclusion: No significant difference was found for right ventricular stroke volume when comparing one breath after 10 chest compressions to two breaths after 30 compressions during automated head-up CPR. Delivering two consecutive breaths after 30 continuous compressions led to an overall higher ETCO2, but it also imposed greater ventricular pressure and afterload, which were significantly correlated with reduced SV and ETCO2.
Abstract Or108: Optimizing Post-resuscitation Care after Resuscitative Endovascular Balloon Occlusion of the Aorta and Automated Head-up Position Cardiopulmonary Resuscitation.
Segond, Nicolas , Pourzand, Pouria , Moore, Johanna , Metzger, Anja, Salverda, Bayert, Suresh, Mithun , Bachista, Kerry, Lurie, Keith G. , Debaty, Guillaume P.

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.or108 Get It

Background: Addition of resuscitative endovascular balloon occlusion of the aorta (REBOA) to automated head-up position (AHUP) cardiopulmonary resuscitation (CPR), the combination of active compression decompression CPR, an impedance threshold device, and controlled gradual elevation of the head and thorax, increases cerebral perfusion pressure. Optimal management of REBOA deflation after prolonged AHUP-CPR and ROSC is unknown. Hypothesis: We hypothesized that partial deflation of REBOA, rather than full deflation after ROSC, would result in better hemodynamic parameters. Aims: To compare hemodynamic parameters 1 minute before and 1 minute after complete (100%) versus partial (50%) REBOA deflation after prolonged AHUP-CPR and ROSC. Methods: Yorkshire pigs weighing ∼40 kg were anesthetized and ventilated. After 10 minutes of untreated ventricular fibrillation, AHUP-CPR was started and continued for a median time of 44 minutes. After ROSC, REBOA deflation was initiated in two ways: complete (100%) or partial (50%) deflation over 5 seconds. The following hemodynamic parameters were measured 1 minute before and 1 minute after deflation: mean aortic pressure (MAP), cerebral perfusion pressure (CerPP), and coronary perfusion pressure (CorPP). Data, in mmHg, are presented as mean ± SD, and compared using a paired t-test. Results: 13 pigs were included, with 8 pigs in the 100% deflation group and 5 in the 50% deflation group. After ROSC in the 100% deflation group, MAP was 81.5±36.0 before deflation vs. 43.0±14.4 after (p=0.01), whereas in the 50% deflation group, MAP was 90.5±33.0 vs. 83.4±33.3 (p=0.02). CerPP was 72.3±34.4 before deflation vs. 35.9±14.6 (p=0.01) in the 100% deflation group, and 84.6±31.2 vs. 77.6±31.8 (p=0.02) with 50% deflation. Similarly, CorPP was 74.1±37.3 before deflation vs. 36.1±15.8 (p=0.01) after in the 100% deflation group, and 83.0±32.7 vs. 76.1±33.0 (p=0.02) in the 50% deflation group. The differences from before to after deflation were markedly less in the 50% deflation group versus the 100% deflation group: MAP (7.0±4.3 vs. 38.5±25.7, p=0.02), CerPP (7.1±4.4 vs. 36.3±24.4, p=0.02), and CorPP (6.0±4.2 vs. 39.8±25.2, p=0.02), respectively. Conclusion: In this porcine model of prolonged cardiac arrest, partial deflation of the REBOA balloon post ROSC resulted in strikingly higher hemodynamics compared with complete deflation. These findings highlight the need to develop a post-ROSC REBOA deflation strategy when used during AHUP-CPR.