Background: Pulsed field ablation (PFA) is an innovative modality for treating arrhythmias that is mostly non-thermal and renders myocardial tissue non-viable by creating pores in cardiac cell membranes. The impact of contact force (CF) on PFA efficacy is not well characterized. Hypothesis: We hypothesize that, while contact is necessary for PFA, increasing CF will not have a significant effect on in vivo ablation lesion size. Aim: We seek to investigate the effects of CF on acute PFA lesions in a beating porcine heart model. Methods: The ventricles of 7 porcine animals were ablated in vivo with PFA (500V, at 20μs for 50 pulses separated by 200ms) using a focal bipolar irrigated ablation catheter and BTX 830 electroporation generator (Harvard Apparatus). CF was measured before and after each PFA application using CARTO 3. Lesions were divided into standard CF (5-15g), high CF (16-30g), and very high CF (>31g). Results: A total of 46 lesions were analyzed. Gross pathology showed no significant difference in maximum width, lesion depth, and lesion volume between the three groups ( Figure 1A-B ). Linear regression showed a decrease of 0.003 mm in depth (depth = -0.003 × CF + 1.8, R = 0.05), an increase of 0.01 mm in width (width = 0.01 × CF + 5.7, R = 0.09), and a decrease of 0.05 mm 3 in volume (volume = -0.05 × CF + 26.8, R = 0.03) for each additional gram of CF ( Figure 1C ). Conclusion: While contact is necessary, increasing CF did not have a significant effect on in-vivo PFA lesion dimensions in a beating porcine heart model.
Abstract 4135869: Local Ethanol Infusion after Pulsed Field Ablation Enhances Acute Efficacy of In Vivo Ventricular Electroporation
Background: Pulsed field ablation (PFA) has emerged as an innovative technology for treating cardiac arrhythmias. PFA increases cell permeability, which can lead to apoptosis. Greater PFA energy may be necessary to ablate ventricular myocardium for ventricular tachycardia circuits, but this carries risks of side effects such as gaseous formation (microbubbles) and hemolysis. Ethanol (EtOH) infusion has been used to ablate pathologic myocardial tissues in hypertrophic cardiomyopathy and for refractory arrhythmias. Hypothesis: We hypothesize that PFA in the ventricle can increase EtOH uptake through PFA-generated pores, thereby enhancing ablation efficacy, even at low powers, by utilizing the cell permeability effects of PFA. Aim: The aim of this study is to investigate the effect of local EtOH infusion after PFA on lesion size in porcine ventricles. Methods: The ventricles of five porcine subjects were ablated in vivo with a PFA low power setting (750 V, at 20 μs for 50 pulses separated by 200 ms) using a focal bipolar irrigated ablation catheter and BTX 830 electroporation generator (Harvard Apparatus). After PFA was performed, 2 ml of 90 % EtOH vs. saline (control) was infused through the catheter tip to the site of ablation. We compared the electrograms voltage amplitude reduction before and after PFA, and the ablation lesion characteristics. Results: A total of 10 lesions in the control group and 9 lesions in the EtOH group were analyzed. For the controls, the voltage after PFA was not reduced. In contrast, for the EtOH group, the voltage after PFA was significantly reduced ( Figure 1A ). On gross pathology, there were significant differences in ablation lesion depths and volumes between the 2 lesion sets ( Figure 1A-B ). Conclusion: Local EtOH infusion after ventricular PFA enhanced acute efficacy of electroporation. Concurrent PFA with local EtOH infusion has the potential to improve efficacy without requiring higher energy parameters, thereby reducing PFA risks. Future studies on chronic efficacy are warranted.
Abstract 4114716: Concurrent Ethanol Infusion with Pulsed Field Ablation Augments Electroporation of Porcine Atria
Background: Pulsed field ablation (PFA) is a promising modality for treatment of cardiac arrhythmias. PFA increases cell permeability, thereby promoting cell apoptosis. Although greater PFA energy may produce larger lesions, it also carries risks of side effects such as arcing, hemolysis, and microbubbles. Chemical ablation using ethanol (EtOH), such as with injection of the Vein of Marshall, has been used to treat atrial myocardium for refractory atrial arrhythmias. Hypothesis: We hypothesize that PFA in the atria can increase EtOH uptake through PFA-generated pores, thereby augmenting ablation efficacy by utilizing the cell permeability effects of PFA. Aim: The aim of this study is to investigate the effects of local EtOH infusion after PFA on lesion size in porcine atria. Methods: The atria of five porcine subjects were ablated in vivo with low PFA power settings (250V, at 20μs for 50 pulses separated by 200 ms) using a focal bipolar irrigated ablation catheter and BTX 830 electroporation generator (Harvard Apparatus). After PFA, 2 ml of 90 % EtOH vs. saline (control) was infused through the catheter tip to the site of ablation. We compared electrogram voltage amplitude reduction and ablation lesion parameters before and after PFA. Results: A total of 14 control lesions and 14 EtOH lesions were analyzed. There was significant difference in voltage reduction between two groups ( Figure 1A-B ). On gross pathology, there were significant differences in ablation lesion maximum surface diameter, lesion depth, and volume between the 2 lesion sets ( Figure 1C ). Conclusion: Concurrent EtOH infusion after PFA enhanced acute efficacy of electroporation in porcine atria. Adjuvant therapy has the potential to improve efficacy without requiring higher energy parameters, thereby reducing PFA risks. Further studies to assess chronic efficacy are warranted.