Comparison of ocular biomechanical properties in normal and glaucomatous eyes using ultrasound surface wave elastography
Kazemi, Arash , Sit, Arthur J. , Zhou, Boran , Zhang, Xiaoming

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1675-1675

10.1121/1.5101144 Get It

Biomechanical properties of the eye are important in understanding glaucoma. However, specific tissues that may be affected are unclear. In this study, we compared glaucomatous and normal eyes for differences in corneal tissue elasticity (as indicated by wave speed) and global ocular rigidity. Both eyes of 10 glaucoma patients and 10 normal controls, matched for age and intraocular pressure (IOP), were included. The ocular rigidity coefficient was calculated from supine IOP measured with and without a 10 g weight added to the tonometer. The wave speed in the cornea was measured by ultrasound surface wave elastography. With this technique, a spherical-tipped probe (4 mm diameter) was placed on the closed eyelid and vibrated at 100 Hz for 0.1 s. The wave speed was calculated using the phase gradient method. Measurements for normal and glaucoma eyes were compared using generalized estimating equation models. The corneal wave speed was similar between normal and glaucomatous eyes (P = 0.4). However, ocular rigidity was significantly lower in glaucomatous eyes (P < 0.001) compared with normal eyes. There was no difference in age or IOP (P > 0.3). Lower ocular rigidity in glaucomatous eyes suggests that a more compliant ocular shell may predispose to glaucoma. However, the lack of difference in the corneal wave speed suggests that corneal tissue is not significantly affected, and changes likely involve the sclera.
An ultrasound surface wave elastography technique for non-invasive measurement of scar tissue
Wyles, Saranya P. , Meves, Alexander , Moran, Steven L. , Zhou, Boran , Zhang, Xiaoming

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1676-1676

10.1121/1.5101147 Get It

Hypertrophic scars and keloids are characterized by excessive fibrosis and can be functionally problematic. Indeed, hypertrophic scarring is characterized by wide, raised scars that remain within the original borders of injury and have a rapid growth phase. There is a need for quantitative scar measurement modalities to effectively evaluate and monitor treatments. We aim to assess the role of the non-invasive scar-measuring device, ultrasound surface wave elastography (USWE), in accurately evaluating scar metrics. Two sites of breast tissue were tested control and scar portions. In USWE, a small, local, and 0.1-s harmonic vibration at three excitation frequencies (100, 150, and 200 Hz) was generated on these sites, and the resulting surface wave speed was measured via an ultrasound probe with a central frequency of 6.4 MHz. There was a statistically significant difference in the wave speed at three frequencies of the scar portion between prior and after treatment, suggesting that the scar portion was softener after treatment. USWE provides an objective assessment of the reaction of the scar to injury and treatment response.
Lung US Surface Wave Elastography in Interstitial Lung Disease Staging
Zhou, Boran , Bartholmai, Brian J. , Kalra, Sanjay , Osborn, Thomas G. , Zhang, Xiaoming , Zhang, Xiaoming , Bartholmai, Brian J

Radiology | March 5, 2019 | Volume: 291 | Issue: 2 | Pages: 479-484

10.1148/radiol.2019181729 Get It

Lung ultrasound surface wave elastography
Zhang, Xiaoming

The Journal of the Acoustical Society of America | October 19, 2018 | Volume: 144 | Issue: 3_Supplement | Pages: 1669-1669

10.1121/1.5067438 Get It

Lung ultrasound surface wave elastography (LUSWE) was developed for noninvasively measuring superficial lung tissue stiffness. In LUSWE, a 0.1 second harmonic vibration is generated on the chest wall of a subject using a handheld vibrator. An ultrasound probe is aligned with the vibration excitation in the same intercostal space to measure the generated surface wave propagation on the lung. A human subject is examined in a sitting position. The lung is tested at the total lung volume and through three intercostal spaces on each lung. In a prospective clinical study, we measure the lung surface wave speeds at 100 Hz, 150 Hz, and 200 Hz on 91 patients with interstitial lung disease (ILD) and 30 healthy control subjects. Significant differences of wave speed between patients and controls were found in all 6 lung regions and for 3 frequencies. We also found positive correlation between LUSWE and clinical assessments including CT and pulmonary function tests. LUSWE is used to track the changes of surface wave speed for patients. LUSWE is a safe and noninvasive technique for generating and measuring surface wave propagation on the lung. LUSWE may complement the clinical standard high-resolution computed tomography for assessing ILD.
Effect of a Thin Fluid Layer on Surface Wave Speed Measurements: A Lung Phantom Study
Zhou, Jinling , Zhang, Xiaoming , Zhang, Xiaoming , Zhou, Jinling

Journal of Ultrasound in Medicine | September 12, 2018 | Volume: 38 | Issue: 5 | Pages: 1361-1365

10.1002/jum.14802 Get It

Lung ultrasound (US) surface wave elastography (SWE) is a novel technique that measures superficial lung tissue elastic properties. A thin pleural fluid layer covers a lung, but its effect on lung measurements in SWE is unknown. We modeled a lung and pleural fluid with sponges and a thin layer of US transmission gel. Sponge surface wave speeds measured from SWE were compared for sponges without and with the thin US gel layer at 3 wave excitation frequencies. The comparison showed that the sponge surface wave speed measurements were not affected by the thin gel layer.
Assessment of Interstitial Lung Disease Using Lung Ultrasound Surface Wave Elastography
Clay, Ryan , Bartholmai, Brian J. , Zhou, Boran , Karwoski, Ronald A., Peikert, Tobias, Osborn, Thomas G. , Rajagopalan, Srinivasan, Kalra, Sanjay , Zhang, Xiaoming , Karwoski, Ronald, Zhang, Xiaoming , Bartholmai, Brian J

Journal of Thoracic Imaging | June 5, 2018 | Volume: 34 | Issue: 5 | Pages: 313-319

10.1097/rti.0000000000000334 Get It

Purpose: Optimal strategies to detect early interstitial lung disease (ILD) are unknown. ILD is frequently subpleural in distribution and affects lung elasticity. Lung ultrasound surface wave elastography (LUSWE) is a noninvasive method of quantifying superficial lung tissue elastic properties. In LUWSE a handheld device applied at the intercostal space vibrates the chest at a set frequency, and the lung surface wave velocity is measured by an ultrasound probe 5 mm away in the same intercostal space. We explored LUWSE’s ability to detect ILD and correlated LUSWE velocity with physiological, quantitative, and visual radiologic features of subjects with known ILD and of healthy controls. Materials and Methods: Seventy-seven subjects with ILD, mostly caused by connective tissue disease, and 19 healthy controls were recruited. LUSWE was performed on all subjects in 3 intercostal lung regions bilaterally. Comparison of LUSWE velocities pulmonary function testing, visual assessment, and quantitative analysis of recent computed tomographic imaging with Computer-Aided Lung Informatics for Pathology Evaluation and Rating (CALIPER) software. Results: Sonographic velocities were higher in all lung regions for cases, with the greatest difference in the lateral lower lung. Median velocity in m/s was 5.84 versus 4.11 and 5.96 versus 4.27 (P<0.00001) for cases versus controls, left and right lateral lower lung zones, respectively. LUSWE velocity correlated negatively with vital capacity and positively with radiologist and CALIPER-detected interstitial abnormalities. Conclusions: LUSWE is a safe and noninvasive technique that shows high sensitivity to detect ILD and correlated with clinical, physiological, radiologic, and quantitative assessments of ILD. Prospective study in detecting ILD is indicated.
Finite element analysis of lung ultrasound surface wave elastography
Zhou, Boran , Zhang, Xiaoming

The Journal of the Acoustical Society of America | April 18, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1803-1803

10.1121/1.5035901 Get It

Interstitial lung disease manifested as fibrotic and stiffened lung tissue, resulting in symptoms such as dyspnea and may lead to respiratory failure. We recently developed a lung ultrasound surface wave elastography for evaluating the elastic properties of superficial lung tissue. In this abstract, we present a finite element analysis to investigate the effects of pleural effusion on the shear wave propagation of superficial lung tissue. The muscle, pleural effusion, and lung tissue were simulated by a 2D planar model of an infinite elastic medium with densities for different materials. A nearly incompressible, linear elastic model was used to model muscle, pleural effusion and lung. The model was excited using a line source on the muscle surface. Harmonic excitations were performed at 100, 150 and 200 Hz with duration of 0.1 s. The boundaries of lung and muscle were attached to an infinite. The mesh of muscle, pleural effusion, and lung were constructed using linear quadrilateral elements. The infinite region was meshed by infinite elements (type CINPE4). The dynamic responses of the tissue model to the excitations were solved by the ABAQUS explicit dynamic solver with automatic step size control. Insignificant difference in shear wave speeds of lung tissue at different excitation frequencies was found in both simulations with and without taking into account the pleural effusion, indicating that pleural effusion does not affect the measurements of shear wave speeds in ultrasound elastography.
Pleural fluid may pose no measurable effect on lung stiffness in lung ultrasound surface wave elastography
Zhou, Jinling , Zhang, Xiaoming

The Journal of the Acoustical Society of America | April 18, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1803-1803

10.1121/1.5035902 Get It

Lung ultrasound surface wave elastography (LUSWE) was developed as a non-invasive tool for assessing pulmonary fibrosis. In this research, the effect of the fleural fluid on surface wave speed measurement of the lung is studied. Low-cost sponges [J. Ultrasound Med. 2017; 36, 2133], as good lung phantoms, were used in this study. The ultrasound transmission gel was used to simulate the pleural fluid. A harmonic vibration was generated at sponge surfaces using a shaker at 100, 150, and 200 Hz. The sponge surface wave speeds were measured with a 6 MHz ultrasound probe for both with and without a thin layer gel. The ultrasound features of A and B-lines were clearly observed in every sponge model in our experiment. The surface wave speeds for the sponges with the gel were indistinguishable from those without the gel for each frequency. The surface wave speeds were faster at higher excitation frequencies which is consistent with our patient study results. It was conclude that the pleural fluid may not affect the lung surface wave speed measurement based upon our lung phantom sponge models.
Phantom study of flow speed measurement using ultrafast ultrasound plane wave imaging
Zhou, Boran , Zhang, Xiaoming

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1901-1901

10.1121/1.5036189 Get It

Color flow imaging is an ultrasound imaging technique widely used to image the blood movement through arteries and veins. Quantification of velocity is urgently demanding. The objective of this study is to use ultrafast plane wave imaging to measure the flow in speed in vitro. For the flow phantom, the diagonal vessel (2-mm inner diameter at 40° angle) was studied with injection of blood mimic fluid via syringe pump at various volume rates (15, 20, 25, and 30 ml/min). Verasonics Vantage system (Verasonics Inc., Kirkland, WA, USA) and a linear array transducer L11-4v (Verasonics Inc., Kirkland, WA, USA) were used for ultrasound acquisition, a 8-angle (−7° to 7°) plane wave compounding with effective pulse-repetition frequency (PRF) of 1000 Hz was used (central frequency = 6.42 MHz, number of transmit cycles = 4). A total of 600 ensembles were acquired. The frame rate was 1000/s.[XZ1] [BZ2] The ultrasound in-phase quadrature data size was 195 × 156 × 600 (axial x lateral x temporal) with data type of complex double. Singular value decomposition (SVD)-based ultrasound blood flow clutter filters was used for ultrafast plane wave imaging.[XZ3] [BZ4] Randomized SVD was utilized to filter noise and tissue motion. Power Doppler image was generated. The color flow images were generated by using the 2-D autocorrelation method. Results showed that color flow measurement can quantitatively evaluate the flow speed in the tube of the flow phantom.
Lung ultrasound surface wave elastography for assessing interstitial lung disease
Clay, Ryan , Zhou, Jinling , Osborn, Thomas G. , Greenleaf, James F. , Kalra, Sanjay , Zhang, Xiaoming , Zhou, Boran , Bartholmai, Brian J.

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1776-1776

10.1121/1.5035812 Get It

A lung ultrasound surface wave elastography (LUSWE) technique is developed for assessing interstitial lung disease (ILD). In LUSWE, a 0.1 second harmonic vibration is generated on the chest wall of a subject using a handheld vibrator. An ultrasound probe is aligned with the vibration indenter in the same intercostal region to measure the generated surface wave speed of the lung. A human subject is examined in a sitting position. The lung is tested at the total lung volume. The upper anterior lungs are tested through the second intercostal space in the mid-clavicular line. The lower lateral lungs are tested in the mid-axillary line and the lower posterior lungs are tested in the mid-scapular line. In a prospective clinical study, we measure both lungs through the six intercostal regions for patients and healthy controls. The surface wave speed is measured at 100 Hz, 150 Hz, and 200 Hz. Significant differences of wave speed between patients and controls were found in all lung regions at all frequencies. We also found positive correlation between LUSWE and CT analyses. LUSWE is a safe and noninvasive technique for generating and measuring surface wave propagation on the lung. LUSWE may be useful for assessing ILD.