Automated measurement of intraperitoneal pressure versus patient fill-volume
Keller, Brad M., Wilmington, Alyssa, Uribarri, Jaime , Sharma, Shuchita , Billah, Marzuq , Mao, Michael, Aslam, Nabeel , Keller, Brad , Uribarri, Jaime , Billah, Marzuq , Rutherford, Peter A.

Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis | April 7, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/08968608261435113 Get It

Measuring intraperitoneal pressure (IPP) has been proposed as a means to help maintain optimal ultrafiltration and prevent complications such as hernias, peritoneal leaks, and gastroesophageal reflux, which are linked with high IPP levels. The Durand method is a commonly accepted method for measuring IPP; however, it is cumbersome and not routinely used in clinics due to its complexity. Here we report the outcome of a pilot study that evaluated the agreement between IPP measured using an in-line pressure transducer and IPP measured using the Durand method during in-clinic automated peritoneal dialysis (APD) therapy. This was an exploratory, descriptive, early feasibility study conducted among patients with a diagnosis of kidney failure who were on APD therapy. IPP was continuously measured using an investigational device (x-MIP transducer) and at fixed timepoints using the Durand method. The study included 10 patients with a median age of 47.0 years and a median body mass index of 28.1 kg/m 2 . The study population was predominantly female, comprising 70% of the participants. The transducer IPP showed a moderate agreement with manual IPP, as most differences in measurements were within ±3 cmH 2 O. Overall, IPP did not correlate with fill-volume. However, when examined on a per-patient level, six patients showed stronger correlations ( ρ > 0.7) between IPP and fill-volume, while the remaining four patients had weaker correlations ( ρ < 0.5). No safety concerns were identified in the study. In summary, this study indicates that a transducer-based IPP measurement device could serve as an alternative to the Durand method.
Successful Measurement of Intraperitoneal Pressure (IPP) in Peritoneal Dialysis Patients With a Pressure Transducer Demonstrates Significant Interindividual Variation and a Complex Relationship With IP Volume
Aslam, Nabeel , Sharma, Shuchita , Billah, Marzuq , Wilmington, Alyssa, Keller, Brad M., Muller, Matthew R., Uribarri, Jaime , Keller, Brad, Rutherford, Peter A.

Journal of the American Society of Nephrology | May 17, 2024 | Volume: 33 | Issue: 11S | Pages: 457-458

10.1681/asn.20223311s1457d Get It

On-Demand Automated Peritoneal Dialysis Solution Generation
Aslam, Nabeel , Edwards, Clinton , Yamagata, Lara Marie, Wellings, Anders J., Wilmington, Alyssa, Uribarri, Jaime , Tran, Ha

Journal of the American Society of Nephrology | May 17, 2024 | Volume: 32 | Issue: 10S | Pages: 325-325

10.1681/asn.20213210s1325b Get It