ABSTRACT Background Clinical T 2 ‐weighted (T2W) MRI of prostate cancer (PCa) usually implements a 2D fast‐spin‐echo (FSE) sequence, but understanding the echo‐time‐dependent contrast behavior is not straightforward due to the complicated FSE signal evolution. Consequently, consensus‐based recommendations on the optimal effective echo time (TE eff ) to maximize contrast are lacking. Purpose To investigate the effect of TE eff on PCa lesion contrast in prostate T2W MRI. Study Type Phantom and in vivo prospective study. Subjects A standard MRI phantom and 53 prostate cancer patients (29 for image evaluation and 24 for quantitative lesion analysis). Field Strength and Sequence Multi‐slice T2W FSE sequence at 3 T acquired at multiple TE eff values. Assessment Three readers (13, 25, and 27 years' experience) evaluated TE eff = 100 ms versus 150 ms on diagnostic quality and reader preference. The effective T 2 relaxation rates ( T 2,eff ) were measured using FSE sequences in the phantom and used to predict the optimal TE eff maximizing T2W contrasts. From multi‐TE eff scans of subjects with suspected PCa, T 2,eff values of PCa lesions and healthy tissue were measured and used to calculate the optimal TE eff maximizing the lesion contrast. In vivo contrast metrics were measured as a function of TE eff . Statistical Tests Wilcoxon test of reader scores, with p < 0.05 defining statistical significance. Results No statistically significant difference was found in diagnostic quality between TE eff = 150 ms and 100 ms images, but all three readers significantly favored TE eff = 150 ms. Phantom experiments demonstrated that TE eff ‐dependent FSE signal progression can be characterized by T 2,eff values typically 40% longer than actual T 2 values, allowing accurate prediction of optimal TE eff within 2%–5%. Applied to PCa imaging, in vivo measurements indicated that effective T 2 relaxation times of the prostate are on average 1.5× longer than published T 2 values. Data Conclusion The benefits of TE eff = 150 ms versus 100 ms in prostate T2W FSE were supported by reader preference, phantom experiments, in vivo measurements, and analytic optimizations. Evidence Level 2. Technical Efficacy 2.
Fertility Preservation in Female Cancer Patients: Comprehensive Clinical, Surgical, and Radiologic Guide for Radiologists
A comprehensive approach that combines imaging, histopathologic analysis, and patient counseling can be used to develop personalized fertility-sparing and fertility-preserving protocols that are safe and effective and respect patient autonomy in making decisions related to their future fertility.
Prostate T2-Weighted Spin-Echo MRI With and Without Glucagon: A Paired Scan Quality Assessment
Abstract Purpose To evaluate the effectiveness of subcutaneous glucagon in reducing motion artifact during prostate MRI through intraindividual comparison. Methods At our institution patients undergoing a clinical prostate MRI exam receive 1 mg of subcutaneous glucagon before scanning. From February 15, 2024 to February 11, 2025 33 such patients were recruited to undergo an additional, research exam without glucagon. All exams were acquired at 3T. An axial T2-weighted spin-echo series (T2-WI) was acquired within both exams. Evaluation of the T2-WI series was done by three experienced radiologists using the criteria of diagnostic quality (0–3 scale), PI-QUALv2 (0–3 sum), motion artifact (significant, visible, none), and reviewer preference (five-point relative scale). Due to differences in prescribed coverage, the scan times for the two T2-WI sequences were in general different for each subject. Results were stratified using the acquisition time ratio (Trel) between the glucagon vs. non-glucagon scans. Wilcoxon tests assessed score differences. Results Across all 33 subjects, no significant differences were found between glucagon and non-glucagon scans. However, the observed negative correlation between glucagon preference and Trel (p = 0.026) led to stratification into low-Trel (n = 16) and high-Trel (n = 17) groups. In the low-Trel group the glucagon scans provided significantly improved diagnostic quality (p = 0.048), PI-QUALv2 sum (p = 0.049), motion scores (p = 0.047), and reader preference (p = 0.042). Conclusion Subcutaneous glucagon provides improved image quality in prostate T2-WI MRI when scan duration remains within 1.25× of that of a non-glucagon T2-WI series. The benefit appears to decrease with longer scan times.
Ultrasound and magnetic resonance imaging features of fetal urogenital anomalies: A pictorial essay
AbstractThis pictorial essay focuses on ultrasound (US) and magnetic resonance imaging (MRI) features of fetal urogenital anomalies. Fetal urogenital malformations account for 30%–50% of all anomalies discovered during pregnancy or at birth. They are usually detected by fetal ultrasound exams. However, when ultrasound data on their characteristics is insufficient, MRI is the best option for detecting other associated anomalies. The prognosis highly depends on their type and whether they are associated with other fetal abnormalities.