Back to Authors

Es, HW. Van

Mayo Clinic

St. Antonius Ziekenhuis

Citations 2

Coronary CTA and CT-FFR in trans-catheter aortic valve implantation candidates: a systematic review and meta-analysis
Becker, Leonie M , Ginkel, Dirk Jan van, Overduin, Daniel, Es, H W Van, Rensing, Benno J. M. W., Timmers, Leo , Hoesein, Firdaus A. A. Mohamed , Peper, Joyce , Es, HW. Van, Ten Berg, Jurrien , Leiner, Tim , Swaans, Martin John

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.1820 Get It

Abstract Objectives To perform a systematic review and meta-analysis on diagnostic accuracy and other outcomes of coronary computed tomography angiography (CCTA) and CT-derived fractional flow reserve (CT-FFR) in candidates for trans-catheter aortic valve implantation (TAVI). Background Screening for obstructive coronary artery disease (CAD) with CCTA during TAVI work-up could prevent unnecessary invasive coronary angiography (ICA). This becomes increasingly relevant as the TAVI-population grows. CT-FFR improves CCTA accuracy in chest pain patients, but its reliability is unknown in the TAVI-population. Methods Pubmed, Embase and Web of Science were searched for studies regarding CCTA and/or CT-FFR in TAVI-candidates. Primary endpoint was correct identification and rule-out of obstructive CAD. Results were pooled in a meta-analysis. Results Twenty-four of the 29 included articles were part of the meta-analysis, reporting results for CCTA and CT-FFR in 3.494 and 797 patients respectively. Reference standard was anatomical severity of CAD in most studies. At patient-level, pooled CCTA sensitivity was 94.3% and specificity 74.8%. CT-FFR sensitivity was 91.5% and specificity 60.3% with strong variation between studies. CCTA correctly ruled out CAD in 52% of all patients, but 42% of positive CCTAs were false positives. CT-FFR correctly ruled out CAD in 47% of all patients included in this meta-analysis, but showed better accuracy than CCTA in studies that compared both. In these studies, sensitivity of CCTA versus CT-FFR was 70.7% versus 79.0% and specificity was 64.4% versus 92.9%. Conclusions Negative CCTA effectively rules-out CAD in the TAVI-population. Adding CCTA to TAVI work-up could lead to significant reduction in pre-TAVI ICA procedures, but the proportion of false-positives remains high. In studies performing a direct comparison, CT-FFR performed better than CCTA. This is not reflected in the CT-FFR meta-analysis. Therefore, diagnostic accuracy of CT-FFR and added value over CCTA in the TAVI-population remains unclear. Further research regarding validation and reliability is warranted.Meta-analysis of CCTA and CT-FFR
Evaluation of automated airway morphological quantification for assessing fibrosing lung disease
Pakzad, Ashkan , Cheung, WK., Moorsel, CHM. Van, Quan, Ke, Bartholmai, Brian J. , Es, HW. Van, Ezircan, A., Beek, F. Van, Veltkamp, Marcel , Karwoski, R., Peikert, Tobias, Clay, RD., Foley, Finbar, Braun, Christian, Sudre, Carole H. , Alexander, Daniel C. , Wijeratne, P. A. , Hawkes, David J. , Hurst, John R. , Jacob, Joseph , Bartholmai, Brian J , Cheung, Wing Keung , Quan, K., Moğulkoç, Nesrin , Clay, Ryan , Savaş, Recep , Doel, Tom , Hu, Y.

Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization | March 31, 2024 | Volume: 12 | Issue: 1 | Pages: No page available

10.1080/21681163.2024.2325361 Get It