AbstractBackgroundPhase four of the Alzheimer’s Disease Neuroimaging Initiative (ADNI4) began in 2023. This time‐period corresponded to MRI vendors introducing product sequences with compressed sensing (CS), cross‐vendor adoption of arterial spin‐labelling (ASL) and multi‐band slice excitation, and hardware improvements (head‐coils, increased gradient amplitudes). These advances enabled the acquisition of new imaging measures and reduced scan times. The ADNI4 MRI protocol aims to maintain longitudinal consistency across two decades of data acquisition, while adopting new technologies. Here we describe the design and justification behind the ADNI4 protocol and list the target imaging biomarkers.MethodsThe ADNI4 MRI protocol includes 9 MRI sequences; i) T1‐weighted (T1w) MP‐RAGE, ii) a compressed sensing T1w MP‐RAGE, iii) 3D T2w FLAIR, iv) structural isotropic 3D T2w v) T2*‐weighted susceptibility imaging vi) multi‐post labelling delay (PLD) 3D ASL, vii) 2D multi‐band‐multiple‐shell diffusion (dMRI), viii) 2D multi‐band EPI BOLD ix) high resolution, limited field of view, imaging centered on the hippocampus. Table 1 gives a detailed summary of the key protocol parameters and lists some of the imaging biomarkers that can be obtained from each series.ResultsStructural imaging was kept consistent across imaging sites. Variations in vendor specific sequences, software upgrades, and hardware performance capabilities, resulted in variations in advanced imaging strategies. Table 2 highlights the advanced sequences introduced in ADNI4, which will gradually be implemented as the required upgrades and licenses are obtained at each site. The main advanced sequences that are new in ADNI4 from ADNI 3 are i) CS for T1w images, ii) pseudo‐continuous‐ASL (pCASL) being implemented on all 3 vendors (GE, Siemens, Philips), iii) multi‐PLD ASL, which allows for the generation of quantitative maps of cerebral blood‐flow (CBF) and arterial transit times (ATTs), iv) and isotropic 1mm3 resolution for 3D FLAIR. When ADNI4 began, product sequences that utilized artificial intelligence were not widely available and could not be adequately tested before the rollout of ADNI4.ConclusionsThe ADNI4 database will continue to help the neuroimaging community, not only extract valuable imaging biomarkers, but provide the data necessary to test the impact of advanced imaging strategies on diagnostic accuracy and disease sensitivity.
Implementation and Validation of Face De‐Identification (de‐facing) in ADNI‐4
AbstractBackgroundRecent advances in automatic face recognition have increased the risk that de‐identified research imaging data could be re‐identified from face imagery in brain scans.MethodAn ADNI committee of independent imaging experts evaluated 11 published techniques for face‐deidentification (“de‐facing”) and selected four algorithms (FSL‐UK Biobank, HCP/XNAT, mri_reface, and BIC) for formal testing using 183 longitudinal scans of 61 racially and ethnically diverse ADNI participants, evaluated by their facial feature removal on 3D rendered surfaces (confirming sufficient privacy protection) and by comparing measurements from ADNI routine image analyses on unmodified vs. de‐faced images (confirming negligible side effects on analyses).ResultEffects of the de‐facing methods on FreeSurfer at UCSF (Figure 1‐top), ASHS at University of Pennsylvania (Figure 1 bottom‐left), and longitudinal atrophy at Mayo Clinic (Figure 1 bottom‐right) were comparable with each other and sufficiently small vs. unmodified scans to recommend de‐facing in ADNI‐4. The FSL and mri_reface methods were more thorough in removing facial features, partly because these also removed ears (Figure 2‐top). mri_reface was recommended for ADNI‐4 primarily because fewer (zero) images had modified brain (Figure 2‐bottom), and ADNI leadership approved de‐facing with mri_reface. ADNI performed a second validation of its latest version on another diverse sample of 100 ADNI‐3 participants. These analyses included: boundary shift interval at University College London, where average differences in measurements were all <0.05%; cortical white matter hyperintensities at UC Davis, where they found “minimum impact” (R>0.97); and others.ConclusionADNI‐4 de‐faces all indicated image types (Table 1) before subsequent pre‐processing, analyses, and public release. Sites upload images to the central repository (LONI), where they are queued to the MRI Core at Mayo Clinic for de‐facing. Image types requiring de‐facing are de‐faced using mri_reface. Trained analysts inspect de‐faced images to confirm complete removal of the face and complete non‐modification of the brain, and any flagged images are re‐processed manually until issues are resolved. De‐faced images are converted back to DICOM and re‐uploaded for further distribution. Image types not requiring de‐facing are indicated to proceed directly to subsequent steps. In summary, ADNI‐4 has adopted mri_reface because it successfully de‐faces without substantially affecting brain measurements.
AbstractBackgroundPhase four of the Alzheimer’s Disease Neuroimaging Initiative (ADNI4) began in 2023. This time‐period corresponded to MRI vendors introducing product sequences with compressed sensing (CS), cross‐vendor adoption of arterial spin‐labelling (ASL) and multi‐band slice excitation, and hardware improvements (head‐coils, increased gradient amplitudes). These advances enabled the acquisition of new imaging measures and reduced scan times. The ADNI4 MRI protocol aims to maintain longitudinal consistency across two decades of data acquisition, while adopting new technologies. Here we describe the design and justification behind the ADNI4 protocol and list the target imaging biomarkers.MethodsThe ADNI4 MRI protocol includes 9 MRI sequences; i) T1‐weighted (T1w) MP‐RAGE, ii) a compressed sensing T1w MP‐RAGE, iii) 3D T2w FLAIR, iv) structural isotropic 3D T2w v) T2*‐weighted susceptibility imaging vi) multi‐post labelling delay (PLD) 3D ASL, vii) 2D multi‐band‐multiple‐shell diffusion (dMRI), viii) 2D multi‐band EPI BOLD ix) high resolution, limited field of view, imaging centered on the hippocampus. Table 1 gives a detailed summary of the key protocol parameters and lists some of the imaging biomarkers that can be obtained from each series.ResultsStructural imaging was kept consistent across imaging sites. Variations in vendor specific sequences, software upgrades, and hardware performance capabilities, resulted in variations in advanced imaging strategies. Table 2 highlights the advanced sequences introduced in ADNI4, which will gradually be implemented as the required upgrades and licenses are obtained at each site. The main advanced sequences that are new in ADNI4 from ADNI 3 are i) CS for T1w images, ii) pseudo‐continuous‐ASL (pCASL) being implemented on all 3 vendors (GE, Siemens, Philips), iii) multi‐PLD ASL, which allows for the generation of quantitative maps of cerebral blood‐flow (CBF) and arterial transit times (ATTs), iv) and isotropic 1mm3 resolution for 3D FLAIR. When ADNI4 began, product sequences that utilized artificial intelligence were not widely available and could not be adequately tested before the rollout of ADNI4.ConclusionsThe ADNI4 database will continue to help the neuroimaging community, not only extract valuable imaging biomarkers, but provide the data necessary to test the impact of advanced imaging strategies on diagnostic accuracy and disease sensitivity.
AbstractBackgroundThe Alzheimer’s Disease Neuroimaging Initiative (ADNI) is a longitudinal observational study of individuals across the dementia spectrum that validates biomarkers for clinical trials. The newest phase of the study, ADNI4, aims to substantially increase the inclusion of underrepresented populations to improve generalizability of ADNI results. Novel biomarkers, including a speech‐based cognitive assessment and blood‐based plasma biomarkers, are integrated into the study design as key participant screening measures.MethodTo help achieve recruitment goals, ADNI4 uses a new, multi‐phase approach to remotely enroll and screen participants. A large study cohort (aiming for 20,000+ participants) provide initial screening data via an online study platform including demographics, medical history related to study exclusionary criteria, and results from a speech‐based cognitive memory assessment (Novoic Ltd. Storyteller test) and a measure of subjective cognitive/functional decline (Everyday Cognition (ECog) 12‐item). Based on screening results, a subset of online study participants is referred to a Quest Diagnostics location to provide a blood sample for plasma biomarker analysis (aiming for 4,000+ participants). Finally, select participants are referred to ADNI clinical sites for in‐depth characterization (goal of up to 1,500 in‐clinic participants).ResultWe report ADNI’s initial approach for selecting participants from the online screening cohort to undergo plasma biomarker phenotyping, and subsequent selection to a clinical site. Participants from diverse demographic backgrounds (especially for race, ethnicity, and/or education) and those with a higher estimated likelihood of cognitive impairment are given priority in the referral selection process. Likelihood of cognitive impairment is assessed using results from subjective memory complaint questions, responses to the ECog 12‐item questionnaire, and the Novoic Storyteller results. Individuals with results showing high concordance across these measures are prioritized, as well as those who have subsequent plasma results indicating biomarker positivity.ConclusionWeighing the various study requirements and inclusivity goals increases the complexity of participant selection decision making, and is a time‐intensive process. As the ADNI study progresses we aim to automate the participant selection/referral process by developing algorithms that account and encode for changing study prioritizations and dynamics across numerous dimensions. Learnings from ADNI4’s new remote processes will help inform future clinical trial design.