Back to Authors

Ahmed, Hasaan

https://orcid.org/0009-0004-7825-8252

Mayo Clinic

Creighton University

Citations 16

A case report of vaping-associated sudden cardiac arrest in a young healthy patient
Ahmed, Hasaan , Palicherla, Anirudh , May, Joshua, Thirumalareddy, Joseph , Ismayl, Mahmoud , Goldsweig, Andrew M.

Annals of Medicine & Surgery | March 15, 2024 | Volume: 86 | Issue: 5 | Pages: 3042-3046

10.1097/ms9.0000000000001907 Get It

Introduction and importance: While vaping has increased significantly among young individuals, the effects of vape aerosol constituents on cardiac electrophysiological dynamics remain unknown. Case presentation: A 22-year-old female with a history of energy vaping presented with cardiac arrest. Found to have no pulse, CPR was started and an initial rhythm of ventricular tachycardia was obtained. Shock was administered with a follow-up rhythm of ventricular fibrillation. She was emergently defibrillated and entered atrial fibrillation with rapid ventricular response. Toxicology and troponins were all negative. Left heart catheterization and cardiac MRI were unremarkable. She was discharged with an external defibrillation vest and a tentative plan for outpatient electrophysiology study in the setting of negative work-up for cardiopulmonary arrest. Clinical discussion: Vaping-induced sudden cardiac arrest may be attributed to a reduction in cardiac repolarization reserve. Exposure to vegetable glycerin and propylene glycol, substances present in nearly all vape products, have been found to incite arrhythmias and disrupt cardiac conduction in animals. Acrolein, an aldehyde byproduct of glycerin, has also been found to induce arrhythmias due to autonomic dysfunction. Increased intracellular calcium concentration and free radical damage, which occur as a result of inhaling particulate matter generated from e-cigarettes, further propagates the risk of arrhythmia. Conclusion: The effects of inhaling vape aerosols remain not fully understood. While there is a perceived notion that nicotine-free aerosols may be harmless, that remains unclear. Further studies are needed to evaluate proarrhythmogenic effects and autonomic dysfunction from the various chemical substances present in vape aerosols.
In-hospital safety outcomes of left atrial appendage occlusion in octogenarians and nonagenarians
Ismayl, Mahmoud , Ahmed, Hasaan , Goldsweig, Andrew M. , Freeman, James V. , Goldsweig, Andrew M , Freeman, James V , Ismayl, Mahmoud , Alkhouli, Mohamad

Europace | February 22, 2024 | Volume: 26 | Issue: 3 | Pages: No page available

10.1093/europace/euae055 Get It

Abstract Aims Data on safety outcomes of left atrial appendage occlusion (LAAO) in elderly patients are limited. This study aimed to compare the outcomes of LAAO between octogenarians (age 80–89) and nonagenarians (age ≥90) vs. younger patients (age ≤79). Methods and results We conducted a retrospective cohort study using the National Inpatient Sample database to identify patients hospitalized for LAAO from 2016 to 2020 and to compare in-hospital safety outcomes in octogenarians and nonagenarians vs. younger patients. The primary outcome was a composite of in-hospital all-cause mortality or stroke. Secondary outcomes included procedural complications, length of stay (LOS), and total costs. Outcomes were determined using logistic regression models. Among 84 140 patients hospitalized for LAAO, 32.9% were octogenarians, 2.8% were nonagenarians, and 64.3% were ≤79 years of age. Over the study period, the volume of LAAO increased in all age groups (all Ptrend < 0.01). After adjustment for clinical and demographic factors, octogenarians and nonagenarians had similar odds of in-hospital all-cause mortality or stroke [adjusted odds ratio (aOR) 1.41, 95% confidence interval (CI) 0.93–2.13 for octogenarians; aOR 1.69, 95% CI 0.67–3.92 for nonagenarians], cardiac tamponade, acute kidney injury, major bleeding, and blood transfusion, in addition to similar LOS and total costs compared with younger patients (all P > 0.05). However, octogenarians and nonagenarians had higher odds of vascular complications compared with younger patients (aOR 1.47, 95% CI 1.08–1.99 for octogenarians; aOR 1.60, 95% CI 1.18–2.97 for nonagenarians). Conclusion Octogenarians and nonagenarians undergoing LAAO have a similar safety profile compared with clinically similar younger patients except for higher odds of vascular complications.
A case report of postcardioversion device-related thrombus in a patient with left atrial appendage occlusion device on apixaban
Ahmed, Hasaan , Palicherla, Anirudh , Heppler, Miranda, Petraskova, Terezia, Kousa, Omar , Vargha, Jalal, Ismayl, Mahmoud

Annals of Medicine & Surgery | January 19, 2024 | Volume: 86 | Issue: 3 | Pages: 1729-1733

10.1097/ms9.0000000000001735 Get It

Background: Current guidelines recommend proceeding with cardioversion, without the explicit need for preprocedural transesophageal echocardiography (TEE), in patients compliant with oral anticoagulation for at least 3 weeks. The relevance of these guidelines remains unclear in those undergoing repeat cardioversion. Case summary: A 66-year-old male with a history of atrial fibrillation (AF) and a left atrial appendage occlusion (LAAO) device, compliant with apixaban, presented with dyspnea and lightheadedness. He was cardioverted into sinus rhythm, 10 days before symptom onset, with TEE unremarkable at the time. An ECG revealed that the patient converted back into AF and a repeat cardioversion was scheduled. At the patient’s request, a TEE was obtained, revealing a new 2 cm×1 cm thrombus in the left atrium above the WATCHMAN device. Cardioversion was canceled and the patient was hospitalized for AF management. Discussion: Cardioverted patients are at risk for thrombus formation due to atrial stunning, a transitory dysfunction of the atrial appendage and atrium, which occurs immediately after cardioversion and can persist for several weeks. The likelihood of a thrombus is further propagated by individual risk factors for stroke. Conclusion: Anticoagulation does not eliminate the risk of thrombus formation in those with increased risk factors for stroke. Further studies are warranted to assess the need for routine TEE, after cardioversion, in those with stroke risk factors on anticoagulation or who have LAAO.
Abstract 18131: Outcomes of Catheter-Based Thrombectomy versus Surgical Embolectomy Among Patients With Massive Pulmonary Embolism: A Nationwide Analysis From the United States
Ahmed, Hasaan , May, Joshua, Hamadi, Omar , Ismayl, Mahmoud , Hashem, Anas , Goldsweig, Andrew M.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18131 Get It

Background: Clinical outcomes of catheter-based thrombectomy (CBT) compared with surgical embolectomy (SE) in patients with massive pulmonary embolism (mPE) have not been previously examined. Methods: We conducted a retrospective cohort study using the 2016-2020 National Inpatient Sample database to compare the outcomes of CBT versus SE in patients with mPE. Outcomes of interest included risk-adjusted in-hospital mortality, major bleeding, stroke, acute kidney injury (AKI), hospital length of stay (LOS), and total cost. Results: The total cohort included 5,845 patients with mPE, of which 5,490 (93.9%) underwent CBT and 215 (3.7%) underwent SE. After risk-adjustment, CBT had similar odds of in-hospital mortality (adjusted odds ratio [aOR] 1.49, 95% confidence interval [CI] 0.60-3.66, p=0.37) and stroke (aOR 1.49, 95% CI 0.30-7.38, p=0.62), lower odds of major bleeding (aOR 0.28, 95% CI 0.13-0.63, p<0.01), and higher odds of AKI (aOR 2.40, 95% CI 1.11-5.17, p=0.02) compared with SE. CBT had a similar LOS (p=0.58) and total cost (p=0.23) compared with SE. Between 2016 and 2020, there was a temporal increase in the performance of CBT in patients with mPE (p trend <0.01). Conclusions: In patients with massive PE, CBT was associated with similar in-hospital mortality, stroke, LOS, and total cost, lower major bleeding, and higher AKI compared with SE. Randomized controlled trials are indicated to confirm our findings.
Abstract 16107: Post-Cardioversion Device-Related Thrombus in a Patient With Left Atrial Appendage Occlusion Device on Apixaban
Ahmed, Hasaan , Palicherla, Anirudh , Heppler, Miranda, Petraskova, Terezia, Kousa, Omar , Graaff, Eric Van De, Ismayl, Mahmoud

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16107 Get It

Introduction and Importance: Current guidelines recommend against pre-procedural transesophageal echocardiogram (TEE) prior to cardioversion in atrial fibrillation patients compliant with oral anticoagulants for at least 3 weeks. The relevance of these guidelines remain unclear in those undergoing repeat cardioversion. Case Presentation: 66-year-old male with a history of atrial fibrillation and an implanted left atrial appendage occlusion device(LAAO), compliant with apixaban, presented with dyspnea and lightheadedness. He was cardioverted into sinus rhythm 10 days prior to symptom onset with TEE unremarkable for thrombus. Vitals were remarkable for tachycardia and electrocardiogram revealed that the patient converted back into atrial fibrillation. Patient was then scheduled for cardioversion. At the patient’s request, a TEE was obtained which revealed a new thrombus in the left atrium located on his WATCHMAN device. Cardioversion was canceled and patient was admitted for coumadin initiation with lovenox bridge along with neurological monitoring due to increased stroke risk. Clinical Discussion: Restoration of sinus rhythm after cardioversion can lead to thrombus formation due to atrial stunning, a transitory dysfunction of the atrial appendage and atrium.Atrial stunning occurs immediately after cardioversion and can persist for several weeks. Time-span of preceding atrial fibrillation, presence of structural cardiovascular disease, and atrial size impact severity of atrial stunning and duration of anticoagulation needed.While anticoagulation decreases the risk of thrombus formation, it does not completely eliminate it, especially in those with increased stroke risk factors. Conclusion: Atrial fibrillation patients are susceptible to thrombus formation after cardioversion.Further studies should be done to assess the need for routine TEE after cardioversion in those with increased risk for stroke on anticoagulants or who have LAAO.
Abstract 16037: Vaping Associated Sudden Cardiac Arrest in a Young Healthy Patient
Ahmed, Hasaan , Palicherla, Anirudh , May, Joshua, Thirumalareddy, Joseph , Ismayl, Mahmoud

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.16037 Get It

Introduction and Importance: While the use of vaping has increased significantly among young individuals, the effects of the various vape aerosol chemical contents on cardiac electrophysiological dynamics remain unknown. Case Presentation: A 22-year-old female with a history of energy vaping but no significant past medical history presented with cardiac arrest. Found to have no pulse, CPR was started and initial rhythm of ventricular tachycardia was obtained. Shock was administered with follow-up rhythm of ventricular fibrillation. Patient was shocked again and entered atrial fibrillation with rapid ventricular response. She later cardioverted into sinus tachycardia and was intubated. Transthoracic echocardiogram showed normal ejection fraction but was otherwise unremarkable. Patient was extubated on day four of hospitalization. Left heart catheterization and cardiac MRI were completely unremarkable. Toxicology, urine analysis, and troponins were all negative. Patient was discharged with metoprolol tartrate, and a life-vest with outpatient follow-ups for possible implantable cardioverter-defibrillator placement in the setting of negative work up for sudden cardiac arrest. Clinical Discussion: Vaping-induced sudden cardiac arrest may be attributed to a reduction in cardiac repolarization reserve. Exposure to vegetable glycerin and propylene glycol, substances present in nearly all vape products, have been found to incite arrhythmias and disrupt cardiac conduction in animals. Acrolein,a byproduct of glycerin, has also been found to induce arrhythmias due to autonomic dysfunction. Increased prevalence of ventricular arrhythmias have also been noted with exposure to aerosols containing nicotine-free propylene glycol (PG).This likely stems from the impact of PG aerosols on the transient outward potassium current, which plays a significant role in early cardiac repolarization. Conclusion: The effects of inhaling vape aerosols remain not fully understood. While there is a perceived notion that nicotine-free aerosols may not be harmful, that remains unclear.Further studies should be conducted to evaluate for pro-arrhythmogenic effects and autonomic dysfunction from the various chemical substances present in vape aerosols.