Evaluation of Intracardiac Pressures Using Subharmonic-aided Pressure Estimation with Sonazoid Microbubbles
Esposito, Cara , Machado, Priscilla , McDonald, Maureen E. , Savage, Michael P. , Fischman, David L. , Mehrotra, Praveen , Cohen, Ira S. , Ruggiero, Nicholas , Walinsky, Paul, Vishnevsky, Alec, Dickie, Kristopher, Davis, Marguerite , Forsberg, Flemming , Dave, Jaydev K. , Fischman, David

Radiology: Cardiothoracic Imaging | February 15, 2024 | Volume: 6 | Issue: 1 | Pages: No page available

10.1148/ryct.230153 Get It

The Effect of Mixing Iodinated Contrast Media and Ultrasound Contrast Agents on Subharmonic Signals
Esposito, Cara , Tzan, Kenneth, Machado, Priscilla , Forsberg, Flemming , Dave, Jaydev K. , Dave, Jaydev K

Ultrasonic Imaging | February 6, 2024 | Volume: 46 | Issue: 2 | Pages: 130-134

10.1177/01617346241227971 Get It

Subharmonic aided pressure estimation (SHAPE) is a technique that utilizes subharmonic signals from microbubble contrast agents for pressure estimation. Validation of the SHAPE technique relies on synchronous measurements of in vivo pressures using contrast microbubbles and a pressure catheter (reference standard). For the guidance and placement of pressure catheter in vivo, iodinated contrast is used with fluoroscopy. Therefore, during data acquisition for validation studies of the SHAPE technique, both contrast microbubbles and iodinated contrast are present simultaneously within the vasculature. This study aims to elucidate the effects of iodinated contrast (Visipaque, GE HealthCare) on subharmonic signal amplitude from contrast microbubbles (Definity, Lantheus Medical Imaging, Inc.). In an acrylic water tank, 0.06 mL of Definity and varied amounts of Visipaque (0.14, 0.43, 0.85, and 1.70 mL) were added to 425 mL of deionized water. Ultrasound scanning was performed with a SonixTablet scanner (BK Medical Systems) using optimized parameters for SHAPE with Definity ( f transmit/receive = 3.0/1.5 MHz; chirp down pulse). Subharmonic data was acquired and analyzed at 9 different incident acoustic outputs ( n = 3). Results showed an increase in subharmonic signal amplitude from Definity microbubbles in the presence of 0.14 mL Visipaque by 2.8 ± 1.3 dB ( p < .001), no change with 0.85 mL Visipaque (0.7 ± 1.2 dB; p = .09) and a decrease in subharmonic amplitude in the presence of 1.70 mL Visipaque by 1.9 ± 0.7 dB ( p < .001). While statistically significant effect on subharmonic signal amplitude of Definity microbubbles was noted due to the mixture, the magnitude of the effect was minimal (~2.8 dB) and unlikely to impact in vivo SHAPE measurements.
Abstract 13299: Are There Differences in Left Ventricular and Aortic Pressures Measured With Fluid-Filled and Solid-State Pressure Catheters
Machado, Priscilla , Cohen, Ira S. , Osler, Brian , McDonald, Maureen E. , Esposito, Cara , Davis, Marguerite , Mehrotra, Praveen , Forsberg, Flemming , Dave, Jaydev K. , Fischman, David L. , Savage, Michael P.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.13299 Get It

Purpose: To compare left-ventricular and aortic pressures obtained using fluid-filled and high-fidelity solid-state pressure catheters in subjects undergoing left heart catheterization. Methods: Twenty subjects scheduled for a left heart catheterization were enrolled and 18 subjects completed this IRB-approved study. During catheterization, left-ventricular (LV) and aortic (AO) pressures were obtained using a fluid-filled pressure catheter (standard-of-care) and a high-fidelity solid-state pressure catheter synchronously. The pressure tracings were analyzed by two independent readers to measure LV systolic (LVSP), LV minimum diastolic (LVMDP), LV end diastolic (LVEDP), AO systolic (AOSP), and AO diastolic (AODP) pressures. Derivatives of the pressure waveforms were computed to estimate the isovolumic contraction and relaxation rates (peak ± dp/dt). The measurements were made over multiple cardiac cycles and averaged results were used for comparisons using repeated measures analysis of variance, post-hoc tests with Bonferroni corrections and Bland-Altman plots. Results: A significant main effect of the pressure catheter was noted for LVSP, LVMDP and AOSP (p < 0.025). The LVSP and AOSP measured with fluid-filled pressure catheters were higher by 6.6 ± 6.9 mmHg and 4.6 ± 5.2 mmHg in comparison to the high-fidelity solid-state pressure catheter assessments. In contrast, the LVMDP measurements were 3.5 ± 5.7 mmHg lower than the solid-state pressure catheter measurements. When evaluating the differences between readers, the maximum difference was noted for LVEDP measurements (3.1 ± 2.4 mmHg; p ≤ 0.001). The differences in isovolumic contraction rate (66.4 ± 116.0 mmHg/s) and relaxation rate (60.5 ± 113.5 mmHg/s) were not significantly different between the two catheter systems after Bonferroni corrections for multiple comparisons (p > 0.06). Bland-Altman analysis revealed a bias ranging from 0.8 to 6.6 mmHg for all the pressure measurements. Conclusions: There are differences in LVSP, LVMDP, and AOSP measured using fluid-filled and high-fidelity solid-state pressure catheters. Clinicians should be aware that the fluid-filled catheters commonly overestimate the true systolic pressures in the left ventricle and aorta.