Back to Authors

Tobah, Yvonne S. Butler

Mayo Clinic

Mayo Clinic

Citations 2

Artificial Intelligence-Derived Age as a Predictor of Cardiovascular Morbidity and Mortality in an Obstetric Population: Results From the SPEC-AI Nigeria Randomized Clinical Trial [ID 1565]
Rose, Carl H., Tobah, Yvonne S. Butler, Adedinsewo, Demilade , Tobah, Yvonne Butler , Johnson, Patrick W. , Noseworthy, Peter A. , Carter, Rickey E.

Obstetrics & Gynecology | May 15, 2025 | Volume: 145 | Issue: 6S | Pages: 81S-81S

10.1097/aog.0000000000005918.091 Get It

INTRODUCTION: The SPEC-AI Nigeria trial (NCT05438576) was designed to use artificial intelligence (AI) to screen for pregnancy-related cardiomyopathy in the peripartum period. Using data from this study, we evaluated the utility of AI-predicted delta age (adjusted AI-predicted age − chronological age) as a surrogate for biological age. METHODS: We included 1,187 pregnant and postpartum women enrolled between August 2022 and September 2023 with follow-up through May 2024. Standard 12-lead electrocardiograms (ECGs) were recorded at study entry to generate AI age predictions. Artificial intelligence-predicted age was adjusted using estimated reference ranges obtained from a community-dwelling cohort of 25,144 individuals with AI-ECG age estimated and documented chronological age. Logistic and Cox-proportional hazards regression were used to examine associations with comorbid cardiovascular conditions and maternal mortality, respectively. RESULTS: Adjusted AI-predicted age was significantly higher among women with any cardiovascular condition, peripartum cardiomyopathy, or who died within 18 months (7, 14, and 23 years older, respectively) compared to those without these conditions who had values similar to the normal reference ranges (adjusted AI-predicted age difference less than 1 year). Artificial intelligence-predicted delta age greater than the 75th percentile was associated with an odds ratio (OR) of 2.06 for any cardiovascular condition, OR of 4.98 for left ventricular systolic dysfunction, and a hazard ratio of 32.81 for all-cause mortality; all values of P<.001. CONCLUSIONS/IMPLICATIONS: Artificial intelligence-ECG-derived biological age appears to be a potentially useful measure of cardiovascular health status and risk among pregnant and postpartum women. However, its role in monitoring maternal health requires further exploration.
Implementing artificial intelligence-based cardio-obstetric screening in a diverse patient population: a prospective study
Morales-Lara, Andrea Carolina , Hardway, Heather D , Young, Kendra A. , Douglass, Erika J. , Tobah, Yvonne S. Butler, Rose, Carl H., Burnette, D P, Friedman, Paul A. , Carter, R E, Adedinsewo, Demilade , Hardway, Heather , Johnson, Patrick W. , Young, K A, Tobah, Yvonne Butler , Burnette, David , Attia, Zachi I. , López-Jiménez, Francisco , Noseworthy, Peter A.

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.2730 Get It

Abstract Background Cardiomyopathy is a leading cause of pregnancy-related mortality and represents the number one cause of death in the late postpartum period. Purpose The goal of this study was to prospectively evaluate the effectiveness of an artificial intelligence-based electrocardiogram (AI-ECG) and a point-of-care artificial intelligence-enhanced digital stethoscope for cardiomyopathy screening among pregnant and postpartum women. Methods We conducted a single-arm prospective study of pregnant and postpartum women (up to 12 months following delivery) enrolled at three sites between October 2021 and October 2022. Study participants completed a standard 12-lead ECG, ECG + phonocardiogram recordings with a digital stethoscope, a demographic questionnaire, and a transthoracic echocardiogram (TTE) within a 24-hour period. Diagnostic performance of the AI-ECG and digital stethoscope for cardiomyopathy detection, defined as left ventricular ejection fraction (LVEF) &lt; 45%, was evaluated using the area under the curve (AUC) and standard measures of diagnostic performance. Results We included 100 consecutive pregnant and postpartum women who provided informed consent and had at least one ECG recorded, completed the questionnaire, and had an echocardiogram performed. All participants self-identified as female, and 41% were recruited from a federally qualified health center. The median age of participants was 31 years (Q1: 27, Q3: 34). Thirty-eight percent identified as non-Hispanic White, 32% as non-Hispanic Black, 21% as Hispanic or Latino, 6% as Asian, and 3% as Other (1 Native Hawaiian and 2 multiracial). Five percent (5/100) had LVEF &lt;45%. The 12-lead AI-ECG model demonstrated close to perfect discrimination (accuracy 99%; AUC 1.00, sensitivity 100%) for detection of cardiomyopathy with 1 false positive screen (LVEF 49%), Figure 1A. The digital stethoscope (angled position) had an AUC of 0.99 (95% CI: 0.97, 1.00) for detection of LVEF &lt;45%. Sensitivity, specificity, positive predictive value, and negative predictive value for the digital stethoscope were 60%, 98%, 60% and 98%, respectively for detection of LVEF &lt;45% (Figure 1B & 1C). Conclusions In this small prospective study, we found that 5% of pregnant and postpartum women had cardiomyopathy, a potentially life-threatening condition, and that a rapid, inexpensive, ubiquitous, massively scalable point-of-care test - the ECG - showed promising results, identifying it with an AUC &gt; 0.98 with the application of artificial intelligence.Figure 1