Back to Authors

Welch, Nick

https://orcid.org/0000-0003-4201-9781

Mayo Clinic

Patient and Public Involvement Representative, London, UK

Citations 2

The UK resuscitative endovascular balloon occlusion of the aorta in trauma patients with life-threatening torso haemorrhage: the (UK-REBOA) multicentre RCT
Jansen, Jan O. , Hudson, Jemma , Kennedy, Charlotte , Cochrane, Claire , MacLennan, Graeme , Gillies, Katie , Lendrum, Robbie , Sadek, Samy , Boyers, Dwayne , Ferry, Gillian , Lawrie, Louisa , Nath, Mintu , Wileman, Samantha , Forrest, Mark , Harris, Tim , Moran, C.G. , Paterson, A. , Tai, Nigel , Welch, Nick , Campbell, Marion , Cochran, Claire , Cotton, Seonaidh , Wileman, Samantha , Forrest, Mark , Brohi, Karim , Harris, Tim , Lecky, Fiona , Moran, Chris , Morrison, Jonathan J , Norrie, John , Paterson, Alan , Tai, Nigel , Welch, Nick , Campbell, Marion K , Jansen, Jan O , Brohi, Karim , Morrison, Jonathan J. , Norrie, John

Health Technology Assessment | September 11, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-122

10.3310/ltyv4082 Get It

Background The most common cause of preventable death after injury is haemorrhage. Resuscitative endovascular balloon occlusion of the aorta is intended to provide earlier, temporary haemorrhage control, to facilitate transfer to an operating theatre or interventional radiology suite for definitive haemostasis. Objective To compare standard care plus resuscitative endovascular balloon occlusion of the aorta versus standard care in patients with exsanguinating haemorrhage in the emergency department. Design Pragmatic, multicentre, Bayesian, group-sequential, registry-enabled, open-label, parallel-group randomised controlled trial to determine the clinical and cost-effectiveness of standard care plus resuscitative endovascular balloon occlusion of the aorta, compared to standard care alone. Setting United Kingdom Major Trauma Centres. Participants Trauma patients aged 16 years or older with confirmed or suspected life-threatening torso haemorrhage deemed amenable to adjunctive treatment with resuscitative endovascular balloon occlusion of the aorta. Interventions Participants were randomly assigned 1 : 1 to: standard care, as expected in a major trauma centre standard care plus resuscitative endovascular balloon occlusion of the aorta. Main outcome measures Primary: Mortality at 90 days. Secondary: Mortality at 6 months, while in hospital, and within 24, 6 and 3 hours; need for haemorrhage control procedures, time to commencement of haemorrhage procedure, complications, length of stay (hospital and intensive care unit-free days), blood product use. Health economic: Expected United Kingdom National Health Service perspective costs, life-years and quality-adjusted life-years, modelled over a lifetime horizon. Data sources Case report forms, Trauma Audit and Research Network registry, NHS Digital (Hospital Episode Statistics and Office of National Statistics data). Results Ninety patients were enrolled: 46 were randomised to standard care plus resuscitative endovascular balloon occlusion of the aorta and 44 to standard care. Mortality at 90 days was higher in the standard care plus resuscitative endovascular balloon occlusion of the aorta group (54%) compared to the standard care group (42%). The odds ratio was 1.58 (95% credible interval 0.72 to 3.52). The posterior probability of an odds ratio > 1 (indicating increased odds of death with resuscitative endovascular balloon occlusion of the aorta) was 86.9%. The overall effect did not change when an enthusiastic prior was used or when the estimate was adjusted for baseline characteristics. For the secondary outcomes (3, 6 and 24 hours mortality), the posterior probability that standard care plus resuscitative endovascular balloon occlusion of the aorta was harmful was higher than for the primary outcome. Additional analyses to account for intercurrent events did not change the direction of the estimate for mortality at any time point. Death due to haemorrhage was more common in the standard care plus resuscitative endovascular balloon occlusion of the aorta group than in the standard care group. There were no serious adverse device effects. Resuscitative endovascular balloon occlusion of the aorta is less costly (probability 99%), due to the competing mortality risk but also substantially less effective in terms of lifetime quality-adjusted life-years (probability 91%). Limitations The size of the study reflects the relative infrequency of exsanguinating traumatic haemorrhage in the United Kingdom. There were some baseline imbalances between groups, but adjusted analyses had little effect on the estimates. Conclusions This is the first randomised trial of the addition of resuscitative endovascular balloon occlusion of the aorta to standard care in the management of exsanguinating haemorrhage. All the analyses suggest that a strategy of standard care plus resuscitative endovascular balloon occlusion of the aorta is potentially harmful. Future work The role (if any) of resuscitative endovascular balloon occlusion of the aorta in the pre-hospital setting remains unclear. Further research to clarify its potential (or not) may be required. Trial registration This trial is registered as ISRCTN16184981. Funding This award was funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme (NIHR award ref: 14/199/09) and is published in full in Health Technology Assessment; Vol. 28, No. 54. See the NIHR Funding and Awards website for further award information.
Emergency Department Resuscitative Endovascular Balloon Occlusion of the Aorta in Trauma Patients With Exsanguinating Hemorrhage
Hudson, Jemma , Cochrane, Claire , MacLennan, Graeme , Lendrum, Robbie , Sadek, Sam, Gillies, Katie , Kennedy, Charlotte , Ferry, Gillian , Lawrie, Louisa , Nath, Mintu , Wileman, Samantha , Forrest, Mark , Brohi, Karim , Harris, Tim , Norrie, John , Paterson, Alan , Tai, Nigel , Welch, Nick , Campbell, Marion , Group, UK-REBOA Study, Bew, Duncan, Brooks, Adam , Chinery, James, Cowlam, Tom, Frith, Dan, George, Arun , Hudson, Anthony, Johnstone, Phillip, Mahmood, Ansar , Novak, Alex , O’Meara, Matt, Reid, Stuart , Sattout, Abdo, Smith, Chris, Stansfield, Tim , Cochran, Claire , Brohi, Karim , Harris, Tim , Norrie, John , Campbell, Marion K , Jansen, Jan O. , Cotton, Seonaidh , Boyers, Dwayne , Lecky, Fiona , Moran, Chris, Morrison, Jonathan J. , Paterson, Alan, Group, UK-REBOA Study, Aylwin, Christopher J , Cowlam, Tom, Thompson, Julian

JAMA | October 12, 2023 | Volume: 330 | Issue: 19 | Pages: 1862

10.1001/jama.2023.20850 Get It

Importance Bleeding is the most common cause of preventable death after trauma. Objective To determine the effectiveness of resuscitative endovascular balloon occlusion of the aorta (REBOA) when used in the emergency department along with standard care vs standard care alone on mortality in trauma patients with exsanguinating hemorrhage. Design, Setting, and Participants Pragmatic, bayesian, randomized clinical trial conducted at 16 major trauma centers in the UK. Patients aged 16 years or older with exsanguinating hemorrhage were enrolled between October 2017 and March 2022 and followed up for 90 days. Intervention Patients were randomly assigned (1:1 allocation) to a strategy that included REBOA and standard care (n = 46) or standard care alone (n = 44). Main Outcomes and Measures The primary outcome was all-cause mortality at 90 days. Ten secondary outcomes included mortality at 6 months, while in the hospital, and within 24 hours, 6 hours, or 3 hours; the need for definitive hemorrhage control procedures; time to commencement of definitive hemorrhage control procedures; complications; length of stay; blood product use; and cause of death. Results Of the 90 patients (median age, 41 years [IQR, 31-59 years]; 62 [69%] were male; and the median Injury Severity Score was 41 [IQR, 29-50]) randomized, 89 were included in the primary outcome analysis because 1 patient in the standard care alone group declined to provide consent for continued participation and data collection 4 days after enrollment. At 90 days, 25 of 46 patients (54%) had experienced all-cause mortality in the REBOA and standard care group vs 18 of 43 patients (42%) in the standard care alone group (odds ratio [OR], 1.58 [95% credible interval, 0.72-3.52]; posterior probability of an OR >1 [indicating increased odds of death with REBOA], 86.9%). Among the 10 secondary outcomes, the ORs for mortality and the posterior probabilities of an OR greater than 1 for 6-month, in-hospital, and 24-, 6-, or 3-hour mortality were all increased in the REBOA and standard care group, and the ORs were increased with earlier mortality end points. There were more deaths due to bleeding in the REBOA and standard care group (8 of 25 patients [32%]) than in standard care alone group (3 of 18 patients [17%]), and most occurred within 24 hours. Conclusions and Relevance In trauma patients with exsanguinating hemorrhage, a strategy of REBOA and standard care in the emergency department does not reduce, and may increase, mortality compared with standard care alone. Trial Registration isrctn.org Identifier: ISRCTN16184981