Back to Authors

Bai, Rong

https://orcid.org/0000-0002-3106-7318

Mayo Clinic

Banner - University Medical Center Phoenix

Citations 2

Use of three-dimensional electroanatomic mapping for epicardial access: needle tracking, electrographic characteristics, and clinical application
Yu, Ronghui , Liu, Nian , You, Binquan , Wang, Haixiong , Ruan, Yanfei , Wen, Songnan , Weiss, J. Peter , Zawaneh, Michael , Su, Wilber , Tung, Roderick , Zhao, Xin , Wang, Wei , Tang, Ribo , Bai, Rong , Weiss, Peter J , Su, Wilber W , Zawaneh, Michael S.

Europace | April 8, 2024 | Volume: 26 | Issue: 5 | Pages: No page available

10.1093/europace/euae089 Get It

Abstract Aims Pericardiocentesis is usually completed under fluoroscopy. The electroanatomic mapping (EAM) system allows visualizing puncture needle tip (NT) while displaying the electrogram recorded from NT, making it possible to obtain epicardial access (EA) independent of fluoroscopy. This study was designed to establish and validate a technique by which EA is obtained under guidance of three-dimensional (3D) EAM combined with NT electrogram. Methods and results 3D shell of the heart was generated, and the NT was made trackable in the EAM system. Unipolar NT electrogram was continuously monitored. Penetration into pericardial sac was determined by an increase in NT potential amplitude and an injury current. A long guidewire of which the tip was also visible in the EAM system was advanced to confirm EA. Epicardial access was successfully obtained without complication in 13 pigs and 22 patients. In the animals, NT potential amplitude was 3.2 ± 1.0 mV when it was located in mediastinum, 5.2 ± 1.6 mV when in contact with fibrous pericardium, and 9.8 ± 2.8 mV after penetrating into pericardial sac (all P ≤ 0.001). In human subjects, it measured 1.54 ± 0.40 mV, 3.61 ± 1.08 mV, and 7.15 ± 2.88 mV, respectively (all P < 0.001). Fluoroscopy time decreased in every 4–5 cases (64 ± 15, 23 ± 17, and 0 s for animals 1–4, 5–8, 9–13, respectively, P = 0.01; 44 ± 23, 31 ± 18, 4±7 s for patients 1–7, 8–14, 15–22, respectively, P < 0.001). In five pigs and seven patients, EA was obtained without X-ray exposure. Conclusion By tracking NT in the 3D EAM system and continuously monitoring the NT electrogram, it is feasible and safe to obtain EA with minimum or no fluoroscopic guidance.
Reconsideration of the definition of blanking period and significance of early recurrences after catheter ablation of atrial fibrillation
Wen, Songnan , Liao, Yu , Khurana, Tejas S., Bai, Rong

Current Opinion in Cardiology | September 26, 2023 | Volume: 39 | Issue: 1 | Pages: 15-19

10.1097/hco.0000000000001096 Get It

Purpose of review Early recurrence of atrial tachyarrhythmia (ERAT) during blanking period (BP) is not uncommon after catheter ablation of AF. Current guidelines and consensus statements recommend conservative treatment of ERAT. This review summarized recent studies, underlying mechanism and clinical managements of ERAT, and proposed a reconsideration of the definition and clinical significance of BP. Recent findings Recent studies have shown that the entity of ERAT in the very early phase of BP (i.e., first 4 weeks of the 3-month period) is different from those ERATs occurring late which is strongly associated with the late recurrence of atrial tachyarrhythmia. The optimal BP duration suggested by clinical observation ranges from 21 to 58 days. Using antiarrhythmic drugs and early electrical cardioversion are the effective management for ERAT, whereas re-ablation is a reasonable strategy although remains controversial. Summary The definition of BP with a shorter duration, that is, 1 month instead of 3 months post AF ablation, is supported by the observations of latest clinical studies. Recurrent atrial tachyarrhythmia beyond the 1-month time frame is associated with higher risk of late recurrence and may warrant repeat ablation. A revisit to the guideline recommendation on management of ERAT is needed to change clinical practice.