Back to Authors

Gruenstein, Daniel H.

Mayo Clinic

University of Minnesota

Citations 2

CRISP: Catheterization RISk score for pediatrics: A Report from the Congenital Cardiac Interventional Study Consortium (CCISC)
Nykanen, David, Forbes, Thomas J., Du, Wei , Divekar, Abhay , Reeves, Jaxk, Hagler, Donald J. , Fagan, Thomas E. , Pedra, Carlos A. C., Fleming, Gregory A. , Khan, Danyal , Javois, Alexander J., Gruenstein, Daniel H., Qureshi, Shakeel A. , Moore, Phillip, Wax, David H., Moore, Phillip , Wax, David

Catheterization and Cardiovascular Interventions | November 3, 2015 | Volume: 87 | Issue: 2 | Pages: 302-309

10.1002/ccd.26300 Get It

ObjectivesWe sought to develop a scoring system that predicts the risk of serious adverse events (SAE's) for individual pediatric patients undergoing cardiac catheterization procedures.BackgroundSystematic assessment of risk of SAE in pediatric catheterization can be challenging in view of a wide variation in procedure and patient complexity as well as rapidly evolving technology.MethodsA 10 component scoring system was originally developed based on expert consensus and review of the existing literature. Data from an international multi‐institutional catheterization registry (CCISC) between 2008 and 2013 were used to validate this scoring system. In addition we used multivariate methods to further refine the original risk score to improve its predictive power of SAE's. Results: Univariate analysis confirmed the strong correlation of each of the 10 components of the original risk score with SAE attributed to a pediatric cardiac catheterization (P < 0.001 for all variables). Multivariate analysis resulted in a modified risk score (CRISP) that corresponds to an increase in value of area under a receiver operating characteristic curve (AUC) from 0.715 to 0.741.ConclusionThe CRISP score predicts risk of occurrence of an SAE for individual patients undergoing pediatric cardiac catheterization procedures. © 2015 Wiley Periodicals, Inc.
Successful Coil Embolization of a Large Ascending Aortic Pseudoaneurysm Following Explantation of the EXCOR Pediatric Ventricular Assist Device in a Patient With Acute Fulminant Myocarditis
Arain, Nofil, Bryant, Roosevelt , Ameduri, Rebecca , Gruenstein, Daniel H., Braunlin, Elizabeth , Joyce, Lyle D., Louis, James St.

World Journal for Pediatric and Congenital Heart Surgery | July 20, 2010 | Volume: 1 | Issue: 2 | Pages: 259-261

10.1177/2150135110372639 Get It

Mechanical ventricular assistance has become a reliable tool for the support of children and infants with heart failure. The devices have shown efficacy both as a bridge to transplantation and as a bridge to recovery. The potential complications that may occur with long-term support have not been fully described. This article reports the occurrence of a large pseudoaneurysm associated with the ascending aorta following explantation of the EXCOR Pediatric ventricular assist device. A management strategy for this potentially lethal complication is described.