Back to Authors

Hoppman‐Chaney, Nicole L.

Mayo Clinic

Mayo Clinic in Arizona

Citations 3

Identification of single gene deletions at 15q13.3: further evidence that CHRNA7 causes the 15q13.3 microdeletion syndrome phenotype
Hoppman‐Chaney, Nicole L., Wain, KE, Seger, PR, Dw, Superneau, Hodge, J.C., Superneau, Duane W.

Clinical Genetics | July 9, 2012 | Volume: 83 | Issue: 4 | Pages: 345-351

10.1111/j.1399-0004.2012.01925.x Get It

The 15q13.3 microdeletion syndrome (OMIM #612001) is characterized by a wide range of phenotypic features, including intellectual disability, seizures, autism, and psychiatric conditions. This deletion is inherited in approximately 75% of cases and has been found in mildly affected and normal parents, consistent with variable expressivity and incomplete penetrance. The common deletion is approximately 2 Mb and contains several genes; however, the gene(s) responsible for the resulting clinical features have not been clearly defined. Recently, four probands were reported with small deletions including only the CHRNA7 gene. These patients showed a wide range of phenotypic features similar to those associated with the larger 15q13.3 microdeletion. To further correlate genotype and phenotype, we queried our database of >15,000 patients tested in the Mayo Clinic Cytogenetics Laboratory from 2008 to 2011 and identified 19 individuals (10 probands and 9 family members) with isolated heterozygous CHRNA7 gene deletions. All but two infants displayed multiple features consistent with 15q13.3 microdeletion syndrome. We also identified the first de novo deletion confined to CHRNA7 as well as the second known case with homozygous deletion of CHRNA7 only. These results provide further evidence implicating CHRNA7 as the gene responsible for the clinical findings associated with 15q13.3 microdeletion.
Expanding DNA diagnostic panel testing: is more better?
Klee, Eric W. , Hoppman‐Chaney, Nicole L., Ferber, Matthew J.

Expert Review of Molecular Diagnostics | September 8, 2011 | Volume: 11 | Issue: 7 | Pages: 703-709

10.1586/erm.11.58 Get It

Evaluation of Oligonucleotide Sequence Capture Arrays and Comparison of Next-Generation Sequencing Platforms for Use in Molecular Diagnostics
Hoppman‐Chaney, Nicole L., Peterson, Lisa M., Klee, Eric W. , Middha, Sumit , Courteau, Laura K., Ferber, Matthew J.

Clinical Chemistry | June 20, 2010 | Volume: 56 | Issue: 8 | Pages: 1297-1306

10.1373/clinchem.2010.145441 Get It

BACKGROUND Next-generation DNA sequencing (NGS) techniques have the potential to revolutionize molecular diagnostics; however, a thorough evaluation of these technologies is necessary to ensure their performance meets or exceeds that of current clinical sequencing methods. METHODS We evaluated the NimbleGen Sequence Capture 385K Human Custom Arrays for enrichment of 22 genes. We sequenced each sample on both the Roche 454 Genome Sequencer FLX (GS-FLX) and the Illumina Genome Analyzer II (GAII) to compare platform performance. RESULTS Although the sequence capture method allowed us to rapidly develop a large number of sequencing assays, we encountered difficulty enriching G+C–rich regions. Although a high proportion of reads consistently mapped outside of the targeted regions, >80% of targeted bases for the GAII and >30% of bases for the GS-FLX were covered by a read depth of ≥20, and >90% of bases for the GAII and >80% of bases for the GS-FLX were covered by a read depth of ≥5. We observed discrepancies among sequence variants identified by the different platforms. CONCLUSIONS Although oligonucleotide arrays are quick and easy to develop, some problematic regions may evade capture, necessitating sequential redesigning for complete optimization. Neither sequencing technology was able to detect every variant identified by Sanger sequencing because of well-known drawbacks of the NGS technologies. The rapidly decreasing error rates and costs of these technologies, however, coupled with advancing bioinformatic capabilities, make them an attractive option for molecular diagnostics in the very near future.