Back to Authors

Oderich, Gustavo S.

https://orcid.org/0000-0001-8953-7514

Mayo Clinic

Division of Vascular and Endovascular Surgery, University of Texas in Houston, USA

Citations 64

Up-and-Over Technique for Implantation of Iliac Branch Devices After Prior Aortic Endograft Repair
Dawson, David L. , Sandri, Giuliano de Almeida, Tenorio, Emanuel R. , Tenorio, Emanuel, Tenorio, Emanuel R , Sandri, Giuliano A., Oderich, Gustavo S.

Journal of Endovascular Therapy | January 9, 2018 | Volume: 25 | Issue: 1 | Pages: 21-27

10.1177/1526602817747283 Get It

Purpose: To describe a modified up-and-over access technique for treatment of iliac artery aneurysms in patients with prior bifurcated stent-grafts for endovascular aneurysm repair (EVAR). Technique: This technique uses a coaxial 12-F flexible sheath that is docked with a through-and-through wire into a 7-F sheath advanced from the contralateral femoral approach. This maneuver allows both sheaths to be moved as a unit while maintaining position of the apex of the system as it loops over the flow divider, avoiding damage to or displacing the extant endograft. Once the 12-F sheath is positioned in the iliac limb of the aortic stent-graft and secured in place with the through-and-through wire, the repair is extended into the internal iliac artery using a bridging stent-graft or covered stent introduced via a coaxial sheath. Conclusion: The up-and-over technique with a flexible 12-F sheath mated with a 7-F sheath from the opposite side allows bilateral femoral access to be used for iliac branch device placement after prior aortic endograft procedures that create a higher, acutely angled bifurcation. Use of a through-and-through wire and a coaxial sheath for stent delivery creates a very stable platform for intervention.
Response to “Re: ‘Snare-Ride: A Bailout Technique to Catheterize Target Vessels With Unfriendly Anatomy in Branched Endovascular Aortic Repair’”
Ferreira, Marcelo , Katsargyris, Αthanasios , Rodrigues, Eduardo, Ferreira, Diego, Cunha, Rodrigo, Bicalho, Guilherme , Verhoeven, Eric L.G. , Oderich, Gustavo, Rodrigues, Eduardo, Oderich, Gustavo S.

Journal of Endovascular Therapy | September 19, 2017 | Volume: 24 | Issue: 5 | Pages: 752-752

10.1177/1526602817729278 Get It

Endovascular Repair of a Thoracoabdominal Aortic Aneurysm With a Patient-Specific Fenestrated-Branched Stent-Graft
Mendes, Bernardo C. , Greiten, Lawrence E. , Oderich, Gustavo S.

Journal of Endovascular Therapy | July 27, 2017 | Volume: 24 | Issue: 5 | Pages: 665-669

10.1177/1526602817722153 Get It

Purpose: To describe the technical aspects of a thoracoabdominal aortic aneurysm (TAAA) repair using a patient-specific fenestrated-branched stent-graft. Technique: The technique is demonstrated in a 69-year-old man with a 6.2-cm asymptomatic type III TAAA. A patient-specific fenestrated-branched stent-graft was designed with 2 down-going directional branches for the celiac and superior mesenteric arteries and 2 reinforced fenestrations for the renal arteries. The procedure was performed under general anesthesia and included sequential stenting of the celiac, superior mesenteric, and bilateral renal arteries. The patient was discharged from the hospital on postoperative day 5 with no complications. Follow-up computed tomography angiography demonstrated exclusion of the aneurysm and patent target vessels at 12-month follow-up. Conclusion: This article and illustrated video highlight the steps for procedure planning and implantation of fenestrated and branched endografts. As these techniques continue to evolve, outcomes are expected to be equivalent or improved as compared to those of long-established open repair.
“Snare-Ride”: A Bailout Technique to Catheterize Target Vessels With Unfriendly Anatomy in Branched Endovascular Aortic Repair
Ferreira, Marcelo , Katsargyris, Αthanasios , Rodrigues, Eduardo, Ferreira, Diego, Cunha, Rodrigo, Bicalho, Guilherme , Oderich, Gustavo S. , Verhoeven, Eric L.G. , Oderich, Gustavo, Rodrigues, Eduardo, Oderich, Gustavo S.

Journal of Endovascular Therapy | May 18, 2017 | Volume: 24 | Issue: 4 | Pages: 556-558

10.1177/1526602817709465 Get It

Purpose: To describe a novel endovascular bailout technique for successful completion of target vessel stenting during branched stent-graft repair of thoracoabdominal aortic aneurysms (TAAA) after encountering difficulties with standard catheterization techniques. Technique: Technical difficulties when using fenestrated and branched grafts should be expected, especially in difficult anatomy or when an off-the-shelf device (eg, standard 4-branch device) is used that does not perfectly “match” the anatomy. The “snare-ride technique” facilitates antegrade transaxillary side branch catheterization and stent placement during TAAA branched grafting using a snare via a transfemoral approach. The branch of the graft is catheterized from an axillary access. The respective target vessel is then catheterized via a femoral access. An Indy snare is advanced over the transfemoral wire and positioned near the entrance of the target vessel. The transaxillary wire inside the branch of the graft is then advanced, snared, and pushed inside the target vessel with the snare. The procedure is thereafter continued with antegrade bridging of the target vessel in routine fashion. Conclusion: The snare-ride technique can be a useful maneuver to catheterize target vessels with difficult anatomy in TAAA branched stent-graft repair. Early experience shows safety and feasibility.
The Loop Technique
Gloviczki, Péter , Erben, Young , Oderich, Gustavo S. , Gloviczki, Péter

Journal of Endovascular Therapy | May 17, 2016 | Volume: 23 | Issue: 4 | Pages: 614-617

10.1177/1526602816649372 Get It

Purpose: To describe a bailout technique for use during branched/fenestrated thoracoabdominal aortic aneurysm (TAAA) repair to address celiac artery (CA) dissection. Technique: The technique is demonstrated in a 69-year-old man who underwent fenestrated stent-graft repair of a 6-cm type III TAAA. The main fenestrated stent-graft was positioned without difficulty, and the renal and superior mesenteric arteries were stented. A stent-graft was placed in the CA, but angiography showed the vessel to be occluded by dissection beyond the stent-graft. Wire manipulations to regain access to the true lumen culminated in perforation. At this point, the gastroduodenal artery was catheterized with a 0.035-inch guidewire, which was advanced in retrograde fashion into the CA true lumen and then snared back to the left brachial artery forming a loop. After exchange for a 0.014-inch system, self-expanding stents were deployed into the hepatic artery. Postoperative recovery was uneventful, and the patient was discharged on day 6. At 1-year follow-up, the patient was doing very well. Imaging demonstrated no endoleak, no graft migration, and sac shrinkage to a diameter of 5.1 cm. Conclusion: The “loop technique” can be a very useful and effective bailout maneuver in regaining access to the true lumen of a dissected CA in patients undergoing branched/fenestrated thoracoabdominal aortic aneurysm repair.
Aortic Graft Infection What Have we Learned During the Last Decades ?
Panneton, Jean M. , Oderich, Gustavo S.

Acta Chirurgica Belgica | May 4, 2016 | Volume: 102 | Issue: 1 | Pages: 7-13

10.1080/00015458.2002.11679254 Get It

Commentary: Proximal Uncovered Stent Disconnections With the Standard and Low-Profile Zenith AAA Stent-Grafts
Oderich, Gustavo S. , Oderich, Gustavo S. , Roeder, Blayne A.

Journal of Endovascular Therapy | March 16, 2016 | Volume: 23 | Issue: 2 | Pages: 311-313

10.1177/1526602816636029 Get It

Commentary: Physician-Modified vs Off-the-Shelf Fenestrated and Branched Endografts
Oderich, Gustavo S.

Journal of Endovascular Therapy | January 13, 2016 | Volume: 23 | Issue: 1 | Pages: 110-114

10.1177/1526602815613520 Get It

Neuromonitoring, Cerebrospinal Fluid Drainage, and Selective Use of Iliofemoral Conduits to Minimize Risk of Spinal Cord Injury During Complex Endovascular Aortic Repair
Banga, Péter , Souza, Leonardo Reis de, Hofer, Jan , Gonzalez, Meaghan L. Cazares, Pulido, Juan N. , Cha, Stephen , Gloviczki, Péter , Banga, Peter V, Reis de Souza, Leonardo, Cazares Gonzalez, Meaghan L, Oderich, Gustavo S. , Gloviczki, Péter

Journal of Endovascular Therapy | December 26, 2015 | Volume: 23 | Issue: 1 | Pages: 139-149

10.1177/1526602815620898 Get It

Purpose: To review outcomes of continuous motor/somatosensory-evoked potential (MEP/SSEP) monitoring, cerebrospinal fluid drainage, and selective use of iliofemoral conduits in patients undergoing endovascular repair of descending thoracic aneurysm (DTA) and thoracoabdominal aortic aneurysms (TAAAs). Methods: The clinical data of 49 patients (mean age 75±8 years; 38 men) who underwent endovascular repair of DTA and TAAAs (2011–2014) were reviewed. All patients had cerebrospinal fluid drainage, permissive hypertension (mean arterial pressure ≥80 mm Hg), and MEP/SSEP monitoring. There were 44 (90%) patients with TAAAs and 5 (10%) with DTA. Types I and II TAAAs were repaired in staged procedures. Iliofemoral conduits were used for small iliac arteries and to minimize time of lower extremity ischemia in patients with difficult anatomy. In patients with changes in MEP/SSEPs, a standardized protocol was employed to optimize spinal cord perfusion and restore lower extremity blood flow. Endpoints were mortality, spinal cord injury (SCI), and lower extremity ischemic complications. Results: Sixteen (33%) patients had staged TAAA repair. A total of 163 visceral arteries were targeted by fenestrations and branches (mean 3.7±1.0 vessels/patient). Temporary iliofemoral conduits were used in 16 limbs/14 patients. A stable MEP/SSEP was achieved in all patients. Thirty-one (63%) patients had a ≥75% decrease in MEP/SSEP amplitude in 50 limbs starting on average 75±28 minutes after obtaining vascular access. MEP/SSEP amplitude improved with maneuvers in 12 (39%) patients and returned to baseline with restoration of lower extremity flow in all except 1 patient who developed immediate SCI. Thirty-day mortality was 4%. Three (6%) patients had SCI, 2 permanent and 1 temporary at 14 days. There were no lower extremity ischemic complications. Conclusion: Neuromonitoring predicted immediate SCI and allowed use of a protocol to optimize spinal cord and lower extremity perfusion during complex endovascular aortic repair. Larger clinical experience is needed to evaluate the efficacy of neuromonitoring to prevent SCI.
False Lumen Embolization to Treat Disseminated Intravascular Coagulation After Thoracic Endovascular Aortic Repair of Type B Aortic Dissection
Mendes, Bernardo C. , Reed, Nanette R., Pruthi, Rajiv K. , Oderich, Gustavo S. , Erben, Young

Journal of Endovascular Therapy | November 19, 2015 | Volume: 22 | Issue: 6 | Pages: 938-941

10.1177/1526602815607185 Get It

Purpose: To present a rare case of disseminated intravascular coagulation (DIC) after thoracic endovascular aortic repair (TEVAR) and its novel treatment. Case Report: A 55-year-old man presented with DIC 10 months after TEVAR for chronic type B aortic dissection and descending thoracic aortic aneurysm. He had persistent retrograde flow in the false lumen with a stable aneurysm diameter. The false lumen was embolized with multiple Amplatzer plugs, which promoted false lumen thrombosis. Laboratory evaluation on postoperative day 7 demonstrated resolution of the coagulopathy. Follow-up at 18 months revealed no recurrent DIC; computed tomography angiography showed a stable aortic diameter and excluded thoracic aneurysm sac. Conclusion: This case demonstrates an unusual, potentially fatal postoperative complication of endovascular treatment of type B aortic dissections successfully treated with an innovative endovascular solution.