Back to Authors

Parodi, Federico E.

Mayo Clinic

University of North Carolina at Chapel Hill

Citations 1

Mid-term Renal and Mesenteric Artery Outcomes During Fenestrated and Branched Endovascular Aortic Repair for Complex Abdominal and Thoracoabdominal Aortic Aneurysms in the United States Aortic Research Consortium
Tenorio, Emanuel R. , Schanzer, Andres , Timaran, Carlos H. , Schneider, Darren B. , Mendes, Bernardo C. , Eagleton, Matthew J. , Parodi, Federico E., Gasper, Warren J. , Sweet, Matthew P. , Huang, Ying , Tenorio, Emanuel R , Schneider, Darren B , Farber, Mark , Beck, Adam W , Oderich, Gustavo S.

Annals of Surgery | April 13, 2023 | Volume: 278 | Issue: 4 | Pages: e893-e902

10.1097/sla.0000000000005859 Get It

Objective: To report mid-term outcomes of renal-mesenteric target arteries (TAs) after fenestrated-branched endovascular aortic repair (FB-EVAR) of complex abdominal and thoracoabdominal aortic aneurysm. Background: TA instability (TAI) is the most frequent indication for reintervention after FB-EVAR. Methods: Data from consecutive patients enrolled in 9 prospective nonrandomized physician-sponsored investigational device exemption studies between 2005 and 2020 were reviewed. TA outcomes through 5 years of follow-up were analyzed for vessels incorporated by fenestrations or directional branches (DBs), including TA patency, endoleak, integrity failure, reintervention, and instability. Results: A total of 1681 patients had 6349 renal-mesenteric arteries were targeted using 3720 fenestrations (59%), 2435 DBs (38%), and 194 scallops (3%). Mean follow was 23 ± 21 months. At 5 years, TAs incorporated by fenestrations had higher primary (95 ± 1% vs 91 ± 1%, P < 0.001) and secondary patency (98 ± 1% vs 94 ± 1%, P < 0.001), and higher freedom from TAI (87 ± 2% vs 84 ± 2%, P = 0.002) compared with TAs incorporated by DBs, with no differences in other TA events. DBs targeted by balloon-expandable stent-grafts had significantly lower freedom from TAI (78 ± 4% vs 88 ± 1%, P = 0.006), TA endoleak (87 ± 3% vs 97 ± 1%, P < 0.001), and TA reintervention (83 ± 4% vs 95 ± 1%, P < 0.001) compared with those targeted by self-expandable stent-grafts Conclusions: Incorporation of renal and mesenteric TA during FB-EVAR is safe and durable with high 5-year patency rates and low freedom from TAI. DBs have lower patency rates and lower freedom from TAI than fenestrations, with better performance for self-expandable stent grafts as compared with balloon-expandable stent grafts.