Back to Authors

Schauer, Jacob M.

https://orcid.org/0000-0002-9041-7082

Mayo Clinic

Northwestern University

Citations 3

Assessing mechanical function of peristalsis with functional lumen imaging probe panometry: Contraction power and displaced volume
Halder, Sourav , Pandolfino, John E. , Kahrilas, Peter J. , Koop, Andree , Schauer, Jacob M. , Araujo, Isis K. , Elisha, Guy , Kou, Wenjun , Patankar, Neelesh A. , Carlson, Dustin A.

Neurogastroenterology & Motility | October 17, 2023 | Volume: 35 | Issue: 12 | Pages: No page available

10.1111/nmo.14692 Get It

AbstractBackground and AimsThe distal contractile integral (DCI) quantifies the contractile vigor of primary peristalsis on high‐resolution manometry (HRM), whereas no such metric exists for secondary peristalsis on functional lumen imaging probe (FLIP) panometry. This study aimed to evaluate novel FLIP metrics of contraction power and displaced volume in asymptomatic controls and a patient cohort.MethodsThirty‐five asymptomatic controls and adult patients (with normal esophagogastric junction outflow/opening and without spasm) who completed HRM and FLIP panometry were included. The patient group also completed timed barium esophagram (TBE). Contraction power (estimate of esophageal work over time) and displaced volume (estimate of contraction‐associated fluid flow) were computed from FLIP. HRM was analyzed per Chicago Classification v4.0.Key ResultsIn controls, median (5th–95th percentile) contraction power was 27 mW (10–44) and displaced volume was 43 mL (17–66). 95 patients were included: 72% with normal motility on HRM, 17% with ineffective esophageal motility (IEM), and 12% with absent contractility. Among patients, DCI was significantly correlated with both contraction power (rho = 0.499) and displaced volume (rho = 0.342); p values < 0.001. Both contraction power and displaced volume were greater in patients with normal motility versus IEM or absent contractility, complete versus incomplete bolus transit, and normal versus abnormal retention on TBE; p values < 0.02.ConclusionsFLIP panometry metrics of contraction power and displaced volume appeared to effectively quantify peristaltic vigor. These novel metrics may enhance evaluation of esophageal motility with FLIP panometry and provide a reliable surrogate to DCI on HRM.
The impact of primary peristalsis, contractile reserve, and secondary peristalsis on esophageal clearance measured by timed barium esophagogram
Koop, Andree , Kahrilas, Peter J. , Schauer, Jacob M. , Pandolfino, John E. , Carlson, Dustin A. , Koop, Andree H

Neurogastroenterology & Motility | July 7, 2023 | Volume: 35 | Issue: 10 | Pages: No page available

10.1111/nmo.14638 Get It

AbstractBackgroundPrimary and secondary peristalsis facilitate esophageal bolus transport; however, their relative impact for bolus clearance remains unclear. We aimed to compare primary peristalsis and contractile reserve on high‐resolution manometry (HRM) and secondary peristalsis on functional lumen imaging probe (FLIP) Panometry with emptying on timed barium esophagogram (TBE) and incorporate findings into a comprehensive model of esophageal function.MethodsAdult patients who completed HRM with multiple rapid swallows (MRS), FLIP, and TBE for esophageal motility evaluation and without abnormal esophagogastric junction outflow/opening or spasm were included. An abnormal TBE was defined as a 1‐min column height >5 cm. Primary peristalsis and contractile reserve after MRS were combined into an HRM–MRS model. Secondary peristalsis was combined with primary peristalsis assessment to describe a complementary neuromyogenic model.Key ResultsOf 89 included patients, differences in rates of abnormal TBEs were observed with primary peristalsis classification (normal: 14.3%; ineffective esophageal motility: 20.0%; absent peristalsis: 54.5%; p = 0.009), contractile reserve (present: 12.5%; absent: 29.3%; p = 0.05), and secondary peristalsis (normal: 9.7%; borderline: 17.6%; impaired/disordered: 28.6%; absent contractile response: 50%; p = 0.039). Logistic regression analysis (akaike information criteria, area under the receiver operating curve) demonstrated that the neuromyogenic model (80.8, 0.83) had a stronger relationship predicting abnormal TBE compared to primary peristalsis (81.5, 0.82), contractile reserve (86.8, 0.75), or secondary peristalsis (89.0, 0.78).Conclusions and InferencesPrimary peristalsis, contractile reserve, and secondary peristalsis were associated with abnormal esophageal retention as measured by TBE. Added benefit was observed when applying comprehensive models to incorporate primary and secondary peristalsis supporting their complementary application.
Interrater Reliability of Functional Lumen Imaging Probe Panometry and High-Resolution Manometry for the Assessment of Esophageal Motility Disorders
Chen, Joan W. , Khan, Abraham, Chokshi, Reena V. , Clarke, John O. , Garza, Jose M. , Gupta, Milli , Gyawali, C. Prakash , Jain, Anand , Katz, Philip O. , Konda, Vani J. , Lazarescu, Adriana , Lynch, Kristle L. , Schnoll‐Sussman, Felice , Vela, Marcelo F. , Schauer, Jacob M. , Pandolfino, John E. , Carlson, Dustin A. , Clarke, J , Gyawali, C P , Chen, Joan , Khan, Abraham, Fass, Ronnie , Spechler, Stuart Jon , Yadlapati, Rena , Kahrilas, Peter J.

American Journal of Gastroenterology | April 12, 2023 | Volume: 118 | Issue: 8 | Pages: 1334-1343

10.14309/ajg.0000000000002285 Get It

INTRODUCTION: High-resolution manometry (HRM) and functional lumen imaging probe (FLIP) are primary and/or complementary diagnostic tools for the evaluation of esophageal motility. We aimed to assess the interrater agreement and accuracy of HRM and FLIP interpretations. METHODS: Esophageal motility specialists from multiple institutions completed the interpretation of 40 consecutive HRM and 40 FLIP studies. Interrater agreement was assessed using intraclass correlation coefficient (ICC) for continuous variables and Fleiss' κ statistics for nominal variables. Accuracies of rater interpretation were assessed using the consensus of 3 experienced raters as the reference standard. RESULTS: Fifteen raters completed the HRM and FLIP studies. An excellent interrater agreement was seen in supine median integral relaxation pressure (ICC 0.96, 95% confidence interval 0.95–0.98), and a good agreement was seen with the assessment of esophagogastric junction (EGJ) outflow, peristalsis, and assignment of a Chicago Classification version 4.0 diagnosis using HRM (κ = 0.71, 0.75, and 0.70, respectively). An excellent interrater agreement for EGJ distensibility index and maximum diameter (0.91 [0.90–0.94], 0.92 [0.89–0.95]) was seen, and a moderate-to-good agreement was seen in the assignment of EGJ opening classification, contractile response pattern, and motility classification (κ = 0.68, 0.56, and 0.59, respectively) on FLIP. Rater accuracy for Chicago Classification version 4.0 diagnosis on HRM was 82% (95% confidence interval 78%–84%) and for motility diagnosis on FLIP Panometry was 78% (95% confidence interval 72%–81%). DISCUSSION: Our study demonstrates high levels of interrater agreement and accuracy in the interpretation of HRM and FLIP metrics and moderate-to-high levels for motility classification in FLIP, supporting the use of these approaches for primary or complementary evaluation of esophageal motility disorders.