Back to Authors

Ocasio, Laura

https://orcid.org/0000-0002-5464-1298

Mayo Clinic

The University of Texas Health Science Center at Houston

Citations 1

Technical Pitfalls for Fenestrated-Branched Endovascular Aortic Repair Following PETTICOAT
Baghbani‐Oskouei, Aidin , Tenorio, Emanuel R. , Dias‐Neto, Marina , Vacirca, Andrea , Mirza, Aleem K. , Saqib, Naveed, Mendes, Bernardo C. , Ocasio, Laura , Macedo, Thanila A. , Oderich, Gustavo S. , Baghbani, Aidin , Tenorio, Emanuel R , Oderich, Gustavo S , Dias-Neto, Marina

Journal of Endovascular Therapy | March 30, 2023 | Volume: 31 | Issue: 5 | Pages: 790-796

10.1177/15266028231163439 Get It

Purpose: The Provisional Extension to Induce Complete Attachment Technique (PETTICOAT) uses a bare-metal stent to scaffold the true lumen in patients with acute or subacute aortic dissections. While it is designed to facilitate remodeling, some patients with chronic post-dissection thoracoabdominal aortic aneurysms (TAAAs) require repair. This study describes the technical pitfalls of fenestrated-branched endovascular aortic repair (FB-EVAR) in patients who underwent prior PETTICOAT repair. Technique: We report 3 patients with extent II TAAAs who had prior bare-metal dissection stents treated by FB-EVAR. Two patients required maneuvers to reroute the aortic guidewire, which was initially placed in-between stent struts. This was recognized before the deployment of the fenestrated-branched device. A third patient had difficult advancement of the celiac bridging stent due to a conflict of the tip of the stent delivery system into one of the stent struts, requiring to redo catheterization and pre-stenting with a balloon-expandable stent. There were no mortalities and target-related events after a follow-up of 12 to 27 months. Conclusion: FB-EVAR following the PETTICOAT is infrequent, but technical difficulties should be recognized to prevent complications from the inadvertent deployment of the fenestrated-branched stent-graft component in-between stent struts. Clinical Impact The present study highlights a few maneuvers to prevent or overcome possible complications during endovascular repair of chronic post-dissection thoracoabdominal aortic aneurysm following PETTICOAT. The main problem to be recognized is the placement of the aortic wire beyond one of the struts of the existing bare-metal stent. Moreover, encroachment of catheters or the bridging stent delivery system into the stent struts may potentially cause difficulties.