Back to Authors

Panther, Eric

https://orcid.org/0000-0003-4976-096X

Mayo Clinic

University of Florida

Citations 2

A reproducible method for evaluating the degree and direction of overstuffing of the humeral head component in anatomic total shoulder arthroplasty
Panther, Eric , Hao, Kévin A. , Patrick, Matthew , King, Joseph J. , Wright, Thomas W. , Struk, Aimee M., Wright, Jonathan O. , Panther, Eric J , Schoch, Bradley S , King, Joseph J , Wright, Jonathan O , Hao, Kevin A , Schoch, Bradley S.

Shoulder & Elbow | June 12, 2024 | Volume: 17 | Issue: 3 | Pages: 282-287

10.1177/17585732241258069 Get It

Background Improper sizing of the humeral head component in anatomic total shoulder arthroplasty (ATSA) can overstuff the joint, potentially compromising outcomes. The purpose of this study was to validate a novel method of evaluating glenohumeral joint overstuffing in which superoinferior and mediolateral overstuffing can be evaluated independently relative to the native humeral anatomy. Methods We identified 25 patients who underwent ATSA and the best Grashey radiograph taken within 1 year of follow-up was assessed using our proposed technique. First, a circle overlaying the implanted humeral head was made. Then, Iannotti's Perfect Circle (IPC) was drawn as originally described. Measurements of superior and medial overstuffing were made using our proposed axes. Inter-rater reliability was assessed by computing interclass correlation coefficients (ICC) using a one-way model. Measurements were summarized as the mean and range, with positive values denoting overstuffing. Results The inter-rater reliability for all measurements was excellent (ICC > 0.9). Compared to our method, the IPC method would have missed 77% of overstuffed cases. Conclusion We present a reproducible method to assess glenohumeral joint overstuffing in ATSA. This technique addresses limitations of other methods that underestimate overstuffing. Further study is needed to establish a clinically significant value of overstuffing based on the proposed method.
Techniques for Decreasing Bacterial Load for Open Shoulder Surgery
Panther, Eric , Hao, Kévin A. , Wright, Jonathan O. , Schoch, Jennifer J. , Ritter, Alaina S , King, Joseph J. , Wright, Thomas W. , Schoch, Bradley S , King, Joseph J , Wright, Jonathan O , Hao, Kevin A , Panther, Eric J , Ritter, Alaina S , Schoch, Bradley S.

JBJS Reviews | February 23, 2023 | Volume: 10 | Issue: 11 | Pages: No page available

10.2106/jbjs.rvw.22.00141 Get It

» Benzoyl peroxide (BPO) 5% has been shown to reduce Cutibacterium acnes load on the skin. BPO 5% with miconazole nitrate (MN) 2% may be beneficial, whereas BPO 5% with clindamycin cream 1% to 1.2% does not seem to have additive effects when compared with BPO 5% alone. Chlorhexidine gluconate solutions reduce the total bacterial load on the skin, but do not seem to have a significant effect on C. acnes . » ChloraPrep seems to be the best surgical skin preparation to decrease overall positive skin cultures. Preincisional hydrogen peroxide 3% application has been shown to be a cost-effective practice to inhibit growth of C. acnes . Vancomycin powder before deltopectoral interval closure has antimicrobial effects against C. acnes and is a cost-effective practice. Finally, Bactisure surgical lavage is protective against the formation of biofilms. » IV cefazolin has been shown to be more effective for shoulder arthroplasty infection prophylaxis than antibiotic alternatives such as vancomycin. Thus, patients with a questionable history of penicillin allergy should undergo additional testing. » For shoulder surgery infection prophylaxis, we recommend the use of BPO 5% cream for 5 days preoperatively with chlorhexidine wipes the night before and the morning of surgery. IV cefazolin should be administered perioperatively, and patients with a questionable history of penicillin allergy should be tested. Surgeons should consider preincisional application of hydrogen peroxide 3% for 5 minutes, followed by standard ChloraPrep preparation. Normal saline should be used for preclosure lavage. Finally, application of vancomycin powder deep to the deltopectoral interval closure should be considered.