Back to Authors

Diaz‐Churion, Fabiana

https://orcid.org/0000-0001-8117-5088

Mayo Clinic

Mayo Clinic in Florida

Citations 3

Artificial Intelligence in Rapid On-Site Evaluation of Bronchoscopy Samples
Koratala, Anoop , Chandra, Nikitha C , Pulipaka, Sai Priyanka , Colleti, S., Barrios‐Ruiz, Alanna , Diaz‐Churion, Fabiana , Johnson, Maja, Trujillo, D. Abia, Fernández-Bussy, Sebastián , Lee‐Mateus, Alejandra Yu , Neshat, Sina , Reynolds, Jordan , Akkus, Zeynettin

B110. PROBING THE LUNG: THE LATEST IN INTERVENTIONAL PULMONARY | May 1, 2023 | Volume: No volume available | Issue: No issue available | Pages: A4467-A4467

10.1164/ajrccm-conference.2023.207.1_meetingabstracts.a4467 Get It

Patient With Metastatic Airway Calcification and Hypercalcemia Due to Secondary Hyperparathyroidism
Diaz‐Churion, Fabiana , Lee‐Mateus, Alejandra Yu , Mirzan, Haares, Khoór, András , Fernández-Bussy, Sebastián , Yu Lee-Mateus, Alejandra , Abia‐Trujillo, David

Journal of Bronchology & Interventional Pulmonology | April 14, 2023 | Volume: 30 | Issue: 4 | Pages: 387-390

10.1097/lbr.0000000000000921 Get It

Real‐time visualization of lung malignancy with needle‐based confocal laser endomicroscopy during shape‐sensing robotic‐assisted bronchoscopy
Diaz‐Churion, Fabiana , Lee‐Mateus, Alejandra Yu , Johnson, Margaret M. , Khoór, András , Patel, Neal M. , Reisenauer, Janani , Fernández-Bussy, Sebastián , Fernandez-Bussy, Sebastian , Yu Lee-Mateus, Alejandra , Abia‐Trujillo, David

Respirology Case Reports | February 2, 2023 | Volume: 11 | Issue: 3 | Pages: No page available

10.1002/rcr2.1092 Get It

AbstractRobotic‐assisted bronchoscopy (RAB) improves endoscopic diagnostic yield of solitary pulmonary nodules (SPN). Needle‐based confocal laser endomicroscopy (nCLE) is an emerging technology that allows high‐resolution, in‐vivo, real‐time assessment of living tissues at a cellular and subcellular level. Their combined use has been scarcely reported. We used them simultaneously in three patients with SPNs. For each, the nodule was evaluated with nCLE and sampled for pathology, followed by mediastinal staging. Median age was 77 years (67% male). Median nodule minimum size was 1.8 cm and maximum was 2.1 cm. nCLE detected abnormal patterns suggestive of malignancy for all nodules and pathology confirmed primary lung adenocarcinomas in two patients and lung primary squamous cell carcinoma in the other. The combined use of RAB with nCLE may potentially enhance the differentiation of malignant cells in real‐time and increase sample adequacy, accuracy, and diagnostic yield when biopsying a suspicious pulmonary lesion.