Back to Authors

Banaei, Niaz

https://orcid.org/0000-0001-8501-3000

Mayo Clinic

Stanford Health Care

Citations 2

Accuracy of Plasma Cell-Free DNA Polymerase Chain Reaction for Diagnosis of Coccidioidomycosis
Lalljie, Annalyse , Budvytiene, Indre, Wheat, Joseph, Theel, Elitza S. , Banaei, Niaz

Clinical Infectious Diseases | May 3, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/cid/ciag287 Get It

Abstract Background Coccidioidomycosis is the most prevalent endemic mycosis in the United States. Diagnosis of coccidioidomycosis can be challenging due to limitations of conventional diagnostics. Detection of fungal plasma cell-free DNA (cfDNA) is a novel noninvasive testing modality for the diagnosis of invasive fungal disease. In this study, we characterized the performance of Coccidioides plasma cfDNA polymerase chain reaction (PCR). Methods A retrospective study was conducted in patients with suspected coccidioidomycosis who underwent plasma cfDNA PCR testing and conventional fungal testing for Coccidioides immitis and Coccidioides posadasii. Patients were categorized per the EORTC/MSGERC case definitions as proven or probable for sensitivity analyses and no coccidioidomycosis for specificity analyses. Results Overall, 362 plasma samples from unique patients were included in this study. The overall sensitivity, specificity, and positive- and negative-predictive values of Coccidioides plasma cfDNA PCR at 0.04% prevalence were 57.5% (27/47; 95% CI, 42.2%–71.7%), 100% (315/315; 95% CI, 98.8%–100%), 100% (95% CI, 87.2%–100%), and 100% (95% CI, 100%–100%), respectively. The sensitivity was 33.3% (2/6; 95% CI, 4.3%–77.7%) in patients with pulmonary focal disease, 66.7% (14/21; 95% CI, 43.0%–85.4%; P≥.05) in patients with pulmonary multifocal disease, and 52.6% (10/19; 95% CI, 39.6%–77.9%; P≥.05) in patients with disseminated coccidioidomycosis. In patients with concurrent antigen results, the sensitivity of cfDNA PCR was 58.3% (14/24; 95% CI, 39.6%–77.9%) compared with 37.5% (9/24; 95% CI, 18.8%–59.4%; P≥.05) for antigen. Conclusions Coccidioides plasma cfDNA PCR is modestly sensitive but highly specific, which can be useful for rapid and noninvasive diagnosis of coccidioidomycosis.
2020. Disinfection of Needle-less Connectors Using UVC Light
Rasooly, Julia , Fourkas, Michael, Schears, Gregory J. , Banaei, Niaz

Open Forum Infectious Diseases | December 15, 2022 | Volume: 9 | Issue: Supplement_2 | Pages: No page available

10.1093/ofid/ofac492.1644 Get It

Abstract Background Nearly 50% of post-insertion catheter-related infections are due to microbial ingress from needleless connectors (NC), widely used devices which connect to the end of catheters or infusion sets and enable access for injection of medications and attachment of infusions. Infections arising from NC could result in central line associated bloodstream infection (CLABSI). The clinical guideline for disinfecting NC is to wipe the hub of the NC with a 70% alcohol and to manually scrub the connector surface for at least 15 seconds. Unfortunately, multiple studies have found low compliance with the 15 second disinfection scrub. Methods In this study, we investigated the efficacy of 1 second of ultraviolet light-C exposure in the reduction of the 3 most common CLABSI associated organisms: Staphylococcus aureus, Candida albicans, Candida auris, and Methicillin-resistant Staphylococcus aureus (MRSA). We tested a total of 30 NC samples for each organism with 3 positive controls and 1 negative control. Results The log reductions were 5.68, 5.05, 4.41, and 6.38 for S. aureus, C. albicans, C. auris and MRSA, respectively. Growth of Candida albicans with and without UV-C exposure for 1 second. The figure shows the observed growth of Candida albicans from the surface of the connector with and without UV-C exposure for 1 second, displaying no growth on the agar plate for samples that were exposed to 1 second of UV-C disinfection. Log reduction of tested organisms after exposure of UV-C for 1 second. Table 1 displays the overall log reduction of tested organisms after 1 second of UV-C exposure. The results are shown for positive control concentration and log reduction for the test organisms Staphylococcus aureus, Candida albicans, Candida auras, and Methicillin-resistant Staphylococcus aureus. Conclusion Our findings demonstrate greater than 4 log reduction of common CLABSI-associated organisms with 1 second of UV-C exposure, which we believe would decrease CLABSI rates, increase aseptic technique compliance, and reduce disruption in hospital workflow. Disclosures Julia Rasooly, MS, Puracath Medical, Inc: Board Member|Puracath Medical, Inc: Stocks/Bonds Michael Fourkas, MS, Puracath Medical, Inc: Grant/Research Support Gregory Schears, MD, Puracath Medical, Inc: Advisor/Consultant|Puracath Medical, Inc: Stocks/Bonds.