Abstract Background Reference sets are needed to evaluate performance of multi-cancer detection (MCD) assays. The National Cancer Institute funded the Alliance reference set study to assess MCDs for use in future trials. Methods Individuals with cancer and controls were recruited; blood specimens were collected prior to cancer treatment. A performance evaluation study was designed utilizing reference set samples. Companies (n = 6) were selected to participate based on review of performance data and ability to utilize the blood collection tube. Companies received samples from cancer types their assay was designed to detect (“targeted”), plus additional “non-targeted” and control samples. Companies reported positive/negative calls, risk scores, and tissue-of-origin (TOO) predictions. Sensitivity was computed for early (I-II) and late (III-IV) stage cases, based on positive/negative calls (SEPN) and at fixed 98% specificity (SE98). Specificity and TOO accuracy were computed. Results Five hundred and forty nine cases (encompassing 13 cancer types) and 413 controls from the reference set were included in the study. Companies assessed samples from median 6 (range 5-9) targeted cancer types and median 8 (range: 7-11) overall cancer types. Median (range) specificity was 92.3% (76.5%-98.5%). Median (range) SEPN was 32% (25%-42%) for early stage and 73% (48%-89%) for late stage; while median (range) SE98 was 19% (8%-35%) for early stage and 66% (13%-79%) for late stage. Median sensitivity for non-targeted types was 40% (early stage) and 52% (late stage). Median (range) TOO accuracy (primary predicted site) was 75% (64%-78%). Conclusions Sensitivity and specificity varied widely across assays with early-stage sensitivity substantially lower than late-stage sensitivity. Clinical Trial Registration Number ClinicalTrials.gov identifier NCT05334069.
Does the source of death information affect cancer screening efficacy results? A study of the use of mortality review versus death certificates in four randomized trials
Background Often in randomized controlled trials of cancer screening, cause of death is determined by a mortality review committee. However, little is known regarding how findings from mortality review compare to those from death certificates alone. Purpose To examine the results of four different U. S. trials of cancer screening when death certificate data only were used, as compared to results using all available mortality review information. Methods Trials included were the Health Insurance Plan of New York breast screening trial (HIP), the Minnesota trial of fecal occult blood testing, and the Johns Hopkins and Mayo Lung Projects, which each examined chest x-ray and sputum cytology. The sensitivity, specificity, positive and negative predictive values, and Cohen’s kappa for death certificates were calculated for all arms of all trials. Separate intention-to-screen analyses were conducted for each trial using cause of death information from either death certificates alone or full mortality review data. Results Generally there was excellent agreement between the death certificates and the mortality review committee as to the underlying cause of death (kappa >0.85 in all cases); death certificate agreement was similar between arms in all trials. Modest changes in the screening effectiveness estimates were observed when mortality review information was utilized, ranging from a 9% decrease to a 2% increase in the calculated mortality rate ratios. However, in one instance (HIP) a statistically significant benefit of screening was observed when mortality review committee data were used (rate ratio (RR) 0.77, 95% confidence interval (CI) 0.62— 0.95) but not when death certificate data were used (RR 0.82, 95% CI 0.65—1.03). Limitations Although considered to be the gold standard, even carefully conducted mortality review may result in errors in cause of death assignment. Conclusions For each trial, results were similar regardless of the source of cause of death information. Clinical Trials 2010; 7: 69—77. http://ctj.sagepub.com